◆ Rebuild

Part 8 · Chemistry

Liquid Air, Nitrogen and the Noble Gases

Squeeze air hard, cool it, and let it expand through a valve, and it gets colder each time round until it falls as a pale blue liquid at about −194 °C. Boil that liquid off slowly and it separates into nitrogen, oxygen and argon — gases for fertiliser plants, welding torches, hospitals, light bulbs, neon lamps and growing crystals. Simpler chemical routes give nitrogen and oxygen long before you can build the machine.

Difficulty
●●●●●
Time
An afternoon to make a jar of nitrogen over hot copper; a year or more to build, test and tune a liquid-air machine once you have a high-pressure compressor
Steps from zero
38 prerequisites →

You need first

Ice and RefrigerationBellows to Air Compressors

This unlocks

Natural Gas and HeliumMedical OxygenCryogenics and Superconductors
The full path from nothing — 38 steps before this one
  1. Stone Tools
  2. Cordage and Rope
  3. Fire
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Basic Woodworking
  7. Hunting and Trapping
  8. Charcoal
  9. Pottery
  10. The Kiln
  11. Hides and Leather
  12. Salt
  13. Lime
  14. Bricks
  15. Fermentation
  16. Lye and Potash
  17. The Wheel and Axle
  18. Glass
  19. Firebrick and Refractories
  20. Bellows
  21. The Lathe
  22. Gears
  23. Iron (the Bloomery)
  24. Copper Smelting
  25. Laboratory Glassware
  26. Pumps
  27. The Waterwheel
  28. Blacksmithing
  29. The Blast Furnace and Cast Iron
  30. The Battery
  31. Steel
  32. The Steam Engine
  33. Bellows to Air Compressors
  34. Electrolysis
  35. Hydrogen, Oxygen and Gases
  36. Machine Tools
  37. Ammonia
  38. Ice and Refrigeration
  39. Liquid Air, Nitrogen and the Noble Gases

Do them roughly in this order. See it on the tech tree →

Why it matters

Air is free and everywhere, and it is a mixture of useful gases: about 78 % nitrogen, 21 % oxygen, 0.93 % argon, a trace of carbon dioxide, water vapour, and tiny amounts of neon, helium, krypton and xenon. Pull them apart and you get:

This is one of the most demanding projects in the book, needing a 150–200 bar compressor (Bellows to Air Compressors) and great respect for cold, pressure and oxygen. So the chapter starts with the chemical shortcuts that give nitrogen and oxygen with ordinary glassware.

How it works

Why squeezed gas cools when it expands

When you let compressed gas out through a narrow valve, it comes out colder. A bicycle pump's valve or a gas cylinder's nozzle frosts over for the same reason. The molecules of a real gas attract each other slightly; as the gas spreads out, they must pull away from each other, and the energy for that comes from their own motion — the gas cools. This is the Joule–Thomson effect (named after the two British scientists who measured it in the 1850s). For air at room temperature, the drop is roughly a quarter of a degree for every bar of pressure released: let air down from 200 bar to 1 bar and it cools by about 40–50 °C in one go. The colder the air already is, the larger the drop.

That alone is not enough to reach −194 °C. The trick, found independently by Carl von Linde and William Hampson in 1895, is to make the cold air that has just come out of the valve flow back past the incoming high-pressure air in a countercurrent heat exchanger (Heat Exchangers) — two tubes side by side, gas flowing opposite ways, so heat passes from the warm stream to the cold one. The next batch of air therefore reaches the valve colder than the last, comes out colder still, and cools the next even more. Each lap ratchets the temperature down until, after an hour or more, a few percent of the air leaving the valve is cold enough to stay liquid. It drips into a flask; the rest goes back round.

Air in Cold gas that did not liquefy, warmed again, back to the compressor Lye scrubbertakes out carbon dioxide Compressor3–4 stages, 150–200 bar Oil trap and dryerquicklime takes out water Heatexchanger30–60 m ofcopper tube Throttleair expandsand cools Collecting pota few % liquefies each pass Cold boxpacked with dry wool Dewar flask, −194 °C
Fig. 1 The Linde–Hampson cycle. Compressed, cleaned air flows down the inner tube of a long coiled heat exchanger, through the throttle valve, and partly liquefies. The cold gas that did not liquefy flows back up around the coil, chilling the incoming air, and returns to the compressor.

Gas that does work as it expands — pushing a piston, like a steam engine running backwards — cools far more. Georges Claude's expansion engine of 1902 let machines run at about 40 bar with less power, but its piston must slide at −150 °C, where every ordinary lubricant freezes.

Why liquid air separates

The gases in air boil at different temperatures (all at normal air pressure):

Gas Boils at Share of air
Water 100 °C (freezes at 0 °C) 0–4 %
Carbon dioxide turns straight to gas at −78 °C 0.04 %
Oxygen −183 °C 21 %
Argon −186 °C 0.93 %
Nitrogen −196 °C 78 %
Neon −246 °C 0.0018 %
Helium −269 °C 0.0005 %

Leave liquid air standing in an open flask and the nitrogen boils off first, because it has the lowest boiling point. What remains slowly becomes richer in oxygen and turns from nearly colourless to a pale sky blue (liquid oxygen is blue). That is the simplest separation. Done properly — in a tall column where rising vapour bubbles through falling liquid on tray after tray, as in the alcohol still of Distillation — nitrogen comes out at the top, oxygen collects at the bottom, and argon gathers in a band partway down. Neon and helium never liquefy at all in the machine; they collect as a gas bubble at the top of the condenser.

+20 °C0 °C−50 °C−100 °C−150 °C−200 °C−250 °C Water freezes, 0 °Cdry the air first or it blocks the coil Carbon dioxide freezes, −78 °Cscrub it out with lye Oxygen, argon, nitrogenall boil between −183 and −196 °C Neon, −246 °C Helium, −269 °Cnever liquefy here The separating column Nitrogen gas outtop: coldest, −196 °C Liquid air inhalfway up Argon banddrawn off at the side Liquid oxygenbottom, −183 °C vapour rises,liquid tricklesdown over trays
Fig. 2 Boiling points on a thermometer scale. Water and carbon dioxide freeze out long before air liquefies and must be removed first. Nitrogen, argon and oxygen boil within 13 degrees of each other, which is why a tall column is needed to separate them well.

Method 1: Nitrogen and argon without cold

You do not need liquid air to get nitrogen. Hot copper eats the oxygen out of air and leaves nitrogen behind.

What you need

Item Notes
Hard glass or iron tube 60–80 cm long, 2–3 cm bore (Laboratory Glassware, Metal Pipes and Tubes)
Copper turnings or fine wire 300–500 g, loosely packed (Copper Smelting, Copper Wire)
A charcoal trough or small furnace To keep the tube at a dull red heat along 40 cm of its length
Bellows or a gasholder To push air through slowly (Bellows)
Wash bottle of strong lye Removes carbon dioxide (Lye and Potash)
Tube of quicklime lumps Removes water (Lime)
Gas jars over water For collecting (Hydrogen, Oxygen and Gases)

Step by step

  1. Pack the copper loosely in the middle of the tube, plugged at each end with a twist of copper wire so air can pass but the turnings cannot.
  2. Lay the tube in the charcoal trough and heat the copper to a dull red, about 500–600 °C — just visibly glowing in shade.
  3. Push air slowly through the lye bottle (to strip carbon dioxide), then through the hot copper, at about one bubble a second through the lye. The bright copper turns black from the inlet end forward as it takes up oxygen.
  4. Lead the outgoing gas through the quicklime tube and collect it over water. Throw away the first two jarfuls, which are mostly the air that was in the apparatus.
  5. When the black zone has crept almost to the far end, stop. Regenerate the copper by passing hydrogen or coal gas over it while still hot (Hydrogen, Oxygen and Gases): it turns bright copper-red again and is ready to reuse. Hot charcoal mixed into the turnings also works, but leaves some carbon monoxide in the next batch.

The gas is about 99 % nitrogen and 1 % argon — good enough to feed an ammonia plant, to protect hot metal, or to fill a lamp. Passed repeatedly over red-hot magnesium (Magnesium), which swallows nitrogen too, the last bubble left is nearly pure argon. That is how argon was first found, below.

Oxygen without cold

Oxygen in small amounts comes from splitting water with electricity, or from heating saltpeter or manganese ore — both described in Hydrogen, Oxygen and Gases. Electrolysis gives pure oxygen and is the practical route for a workshop until you have an air-separation plant. For a hospital, the zeolite oxygen concentrator in Medical Oxygen also works without cold.

Method 2: The liquid-air machine

Be honest about this: it is a project for a workshop that can already build a multi-stage compressor, make leak-tight high-pressure joints, and silver glass. Early machines driven by an engine of a few horsepower made around a litre of liquid air an hour after an hour or two of cooling down. That is a lot of liquid nitrogen for a laboratory, a breeding station or a small factory.

What you need

Part Size and notes
Compressor 3 or 4 stages with water-cooled intercoolers, reaching 150–200 bar, at least 10–20 m³ of free air an hour. Each stage multiplies pressure about 4 times (Bellows to Air Compressors)
Oil separator A tall tested pot after the last stage where oil mist settles and is drained
Lye scrubber A tower of strong caustic lye (sodium or potassium hydroxide) the intake air bubbles through, to remove carbon dioxide (Lye and Potash)
Dryers A cooled coil to drop most water, then a tested pressure pot of quicklime or fused calcium chloride (Lime, Hydrochloric Acid)
Heat exchanger 30–60 m of copper tube, 6 mm outside and 3 mm inside, wound in a tight coil about 15–20 cm across inside a closed copper or brass casing
Throttle valve A fine needle valve of brass or bronze, with a long stem so the handle is outside the cold box
Cold box A wooden crate at least 15 cm larger than the coil all round, packed with dry wool, sheep's fleece, cork or sawdust (Insulation and Keeping Buildings Warm or Cool)
Dewar flask Double-walled silvered glass with a vacuum between the walls (The Vacuum Pump, Mirrors)
Pressure gauge and safety valve On every pressure vessel, set below the test pressure (Pressure and Vacuum Gauges)

Tip Use copper, brass, bronze or aluminium for anything that gets cold. Ordinary carbon steel and cast iron turn as brittle as glass below about −40 °C and can shatter under pressure. Copper and its alloys stay tough down to the coldest liquid air.

Step by step

  1. Build and test every pressure part. Fill each pipe, coil and pot with water and pump it to 1.5 times working pressure (300 bar for a 200-bar machine) for 10 minutes, as in Bellows to Air Compressors. Nothing may weep. Never test with air.
  2. Wind the heat exchanger. Anneal the copper tube (heat to dull red and quench) so it bends without kinking. Wind it around a wooden former in a tight helix, then fit it inside a casing so the returning cold gas must flow along the coils, around and between them, from bottom to top. The longer and tighter the contact, the colder the machine gets. Silver-solder all joints (Soldering and Brazing); soft solder is weak when cold.
  3. Mount the throttle valve at the bottom of the coil, with the liquid-collecting pot right beneath it, and a drain tube from the pot to the Dewar flask with its own valve.
  4. Insulate. Set the coil and pot in the cold box and pack every gap with dry wool or fleece. Damp insulation conducts heat and freezes into a solid block; dry it beforehand.
  5. Clean the air. Draw intake air from outdoors, upwind of chimneys and engines, through the lye scrubber. Pass the compressed air through the oil separator, the cooling coil (drain the water that drops out every half hour) and the quicklime dryer. Water and carbon dioxide freeze to ice and dry-ice snow in the cold coil and block it within minutes if not removed.
  6. Start up. Run the compressor up to full pressure with the throttle valve shut. Then open the valve a little, so pressure in the coil stays near 150–200 bar while gas flows out. The returning gas goes back to the compressor intake (it is already clean and dry) or out to air.
  7. Watch the outlet temperature fall. Frost creeps along the outer pipes; the casing sweats and then frosts. After 30 minutes to 2 hours, liquid begins to fall into the pot. You will hear a change in the hiss at the valve, and the return gas suddenly gets much colder.
  8. Draw off liquid into the Dewar flask every 10–20 minutes. Close the throttle a little once liquid appears — you will learn the setting that gives most liquid.
  9. Shut down by stopping the compressor and opening all drains and vents, so trapped liquid boils off into the open. Let the box warm for a day and blow it through with warm dry air before the next run.

Making a Dewar flask

Liquid air in an ordinary jar boils away in minutes. In a vacuum flask — a glass bottle inside a slightly larger glass bottle, joined at the neck, with the air pumped out of the gap — it keeps for many hours. The vacuum stops heat creeping in by air contact; a coat of silver on the inner faces of the gap stops heat arriving as radiation.

  1. Blow two bottles of the same glass, the inner one 5–8 mm smaller all round (Glass, Laboratory Glassware). Use borosilicate glass if you have it; ordinary glass cracks more readily from the cold.
  2. Silver the outside of the inner bottle and the inside of the outer one before joining them, as in Mirrors.
  3. Join the necks by fusing them in the flame, leaving one small side tube on the outer wall.
  4. Pump the gap out through the side tube with your best The Vacuum Pump, warming the flask gently to drive off moisture, then melt the tube shut.
  5. Set the flask in a padded wooden or metal case: a vacuum flask that cracks implodes and throws glass.

Never put a stopper in a flask of liquid air — a loose wad of dry cotton or wool only.

Separating the gases

Simple evaporation

Let a flask of liquid air boil off slowly. The first gas off is mostly nitrogen. After about three-quarters has evaporated, the blue liquid left is very roughly two-thirds oxygen or more. Linde's first oxygen was made just like this. It is crude, but oxygen-rich enough to make a glowing splint burst into flame and to boost a torch.

The column

For pure gases, build a rectifying column: a vertical copper tube, 10–20 cm across and 2–4 m tall, filled with perforated copper trays every 10 cm or packed with copper rings, inside its own cold box. Liquid air from the machine is fed in halfway up. At the bottom, a coil of the incoming high-pressure air (which is slightly warmer than boiling oxygen) boils the liquid; at the top, a cold condenser turns rising vapour back to liquid that trickles down again. Gas leaving the top is nitrogen; liquid drawn off the bottom is oxygen of 95–99.5 %. Linde's double column of 1910, two columns stacked so one condenses the other, is the design almost every plant still uses.

Argon gathers in a band partway up the column (in a double column, about a third of the way up the upper one), where it can reach about 10 %. A side tube draws this off into a smaller column of its own; the last oxygen is removed by burning it with a little hydrogen over hot copper, then drying.

Neon and helium collect in the top of the condenser as a gas that never liquefies. Bleed it off into a small gasholder. A further step over charcoal cooled in liquid nitrogen — which soaks up everything except neon and helium — gives a neon good enough for lamps.

Using the gases

How to tell it worked

  • Nitrogen: a burning splint plunged into a jar goes out at once; lime water shaken in it stays clear (no carbon dioxide); a mouse would die in it, so do not test it on yourself.
  • Oxygen: a glowing splint bursts back into flame; a red-hot iron wire burns with white sparks. The purer the oxygen, the faster.
  • Liquid air: clear to faintly blue, boiling steadily, with white fog pouring over the rim. A rubber tube dipped in it shatters like glass when struck. A flower dipped in it crumbles.
  • Argon and neon: put a sample in a small tube with two electrodes and pass a spark. Neon glows red-orange; argon lilac to blue; nitrogen pinkish-orange; air pink-purple. A The Spectroscope shows the lines exactly.

Note Troubleshooting. Machine gets cold but never makes liquid → heat exchanger too short or too loose; insulation damp or too thin; pressure below 120 bar. Lengthen the coil and repack. Flow stops and pressure climbs after a while → ice or dry-ice snow has blocked the coil or valve. Shut down, open drains, warm and dry it; improve the lye scrubber and dryers. Oily smell or brown film in the pot → compressor oil is getting through. Fix the separator before you ever make oxygen. Copper turns black too fast in Method 1 → you are pushing air too quickly; slow to a bubble a second. Neon tube glows pink instead of red → air has leaked in. Pump out again, warmer and longer.

Dangers

Danger Nitrogen and argon kill without warning. They have no smell and cause no breathlessness. A person who steps into air short of oxygen collapses within a few breaths and dies within minutes, and the would-be rescuer who runs in after them dies too. One litre of liquid nitrogen makes about 700 litres of gas. Never use or store liquid nitrogen or argon in a small closed room, a cellar or a pit; argon is heavier than air and lies in low places. Ventilate. If someone collapses near the machine, do not go in after them without fresh air: open doors, blow air in, and pull them out with a rope or by holding your breath.

Danger Oxygen makes everything burn fiercely. Air with more than about 23 % oxygen turns a spark into a flash fire. Clothing soaked with oxygen gas, or splashed with liquid oxygen, burns like a torch at a touch of flame. Oil, grease, tar, wood, cloth or asphalt soaked with liquid oxygen can explode when struck. Never let oil or grease touch an oxygen valve, regulator or fitting; never lubricate them; never use an air compressor to compress oxygen. No smoking or open flame anywhere near.

Danger Trapped liquid bursts pipes. Liquid air shut between two closed valves warms, boils, and builds pressure until the pipe splits. Every section that can hold liquid needs a vent or a safety valve. Never stopper a flask.

  • Cold burns. Liquid air on skin forms a short vapour cushion, but a splash in the eye, liquid trapped in a glove or boot, or touching cold metal freezes flesh instantly. Wear a face shield of glass, loose leather gloves you can flick off, and long sleeves over the glove tops. Treat cold burns with lukewarm (not hot) water (Wound Care and Antiseptics).
  • Fuel in the oxygen. Traces of oil, acetylene and other burnable gases from the intake air dissolve in liquid oxygen at the bottom of the column and build up over weeks. Several air-separation plants have exploded this way. Draw the intake from clean air, drain the bottom liquid regularly, and never put the machine downwind of carbide works, tar works or engines.
  • High pressure. A 200-bar line that fails whips and sprays like a shot. Test everything with water; shield gauges and joints; never tighten a fitting under pressure (Bellows to Air Compressors).
  • Imploding flasks. Always cased; never handled without eye protection.

What this unlocks

Cheap nitrogen makes Haber–Bosch Ammonia practical, and with it fertiliser and nitric acid from air. Cheap oxygen gives oxy-fuel Welding, oxygen steelmaking (Steel in Quantity) and Medical Oxygen. Argon and the very cold make Pure Silicon, filament lamps and electronics easier, and liquid nitrogen gives the best vacuum traps for The Vacuum Tube making and for X-Rays tubes. The same machine, with better compressors and an expansion engine, can go on to liquefy hydrogen and helium, the starting point of superconductors (Cryogenics and Superconductors).

How it was first done

In 1785 Henry Cavendish in London sparked air with extra oxygen over alkali, again and again, until nearly all the nitrogen had turned to acid and dissolved; a tiny bubble, about 1/120 of the original, refused to go. He noted it and moved on. More than a century later, in 1892, Lord Rayleigh found that nitrogen taken from air weighed about half a percent more than nitrogen made from ammonia. With William Ramsay he removed the nitrogen with red-hot magnesium and in 1894 isolated argon ("the lazy one" in Greek) — Cavendish's bubble. In 1898 Ramsay and Morris Travers, distilling the new liquid air, found neon ("new"), krypton ("hidden") and xenon ("stranger") in a few weeks.

Oxygen was first liquefied as a mist by Louis Cailletet and Raoul Pictet in 1877, and in usable amounts by Zygmunt Wróblewski and Karol Olszewski in Kraków in 1883; James Dewar invented the vacuum flask in 1892. The self-cooling throttle machine was patented in 1895 by Carl von Linde in Munich and William Hampson in England; Linde's company made oxygen by the column from 1902 and built the double column in 1910. In Paris, Georges Claude built the expansion engine in 1902, co-founded the company Air Liquide, and — looking for a use for the neon left over from his oxygen — lit the first neon lamps at the Paris Motor Show in 1910.