◆ Rebuild

Part 13 · Electricity

Rectifiers: Turning AC into DC

Generators and transformers give alternating current, but batteries, electrolysis, plating and telegraphs need current that flows one way. How to turn AC into DC — with a motor driving a dynamo, a vibrating reed, jars of aluminium in borax, stacks of copper-oxide or selenium discs, or a hot-cathode tube — and how to charge a battery safely from the AC mains.

Difficulty
●●●●●
Time
An afternoon to make an electrolytic rectifier jar; a day for a battery charger; a week for a vibrating rectifier or a motor-generator set
Steps from zero
24 prerequisites →

You need first

The TransformerCopper Smelting

This unlocks

Power Supplies and Regulators
The full path from nothing — 24 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. Charcoal
  9. Pottery
  10. Hides and Leather
  11. Fermentation
  12. The Wheel and Axle
  13. Bellows
  14. Gears
  15. Copper Smelting
  16. Iron (the Bloomery)
  17. The Waterwheel
  18. Blacksmithing
  19. The Battery
  20. Magnets
  21. Copper Wire
  22. The Electromagnet
  23. The Generator
  24. The Transformer
  25. Rectifiers: Turning AC into DC

Do them roughly in this order. See it on the tech tree →

Why it matters

Once you have a The Transformer, alternating current (AC) is the best way to make and send electricity (Power Lines and Distribution). But many of the most useful jobs need direct current (DC) — current that always flows the same way:

A rectifier is a one-way valve for electricity. It lets current through in one direction and blocks it in the other, turning AC into a pulsing but one-way current. This chapter gives five ways to build one, from the most mechanical to the most electronic, and a complete battery charger.

How it works

The AC wave

AC rises from zero to a peak in one direction, falls back through zero, peaks in the other direction, and returns — 50 or 60 times a second from a mains generator. Its effective (RMS) voltage is what a meter usually reads and what heats a lamp. Its peak voltage is higher: peak = 1.41 × RMS. A 20 V AC supply swings up to 28 V and down to −28 V.

Three ways to connect a rectifier

AC in from the transformer swings both ways;peak = 1.41 × RMS Half-wave one rectifier load orbattery only forward halves pass: average 0.45 × RMS Bridge − + out four rectifiers both halves, turned one way: average 0.9 × RMS time
Fig. 1 Rectifier circuits. The AC input swings both ways. One rectifier (half-wave) passes only the forward halves. Four rectifiers in a bridge pass both halves, turned the same way. Each triangle points the way current can flow.
  1. Half-wave: one rectifier in series. Only the forward halves pass; the other halves are wasted. The average DC is only 0.45 × the AC (RMS) voltage. Simple, but it wastes half the transformer's time and gives a rough output.
  2. Full-wave, centre-tapped: a transformer secondary with a connection in the middle, and two rectifiers. Each half of the winding works in turn. Average DC is 0.9 × the RMS voltage of each half.
  3. The bridge (Graetz bridge): four rectifiers in a diamond. On one half-cycle current goes through one pair; on the other half, through the other pair — always leaving by the same output terminal. Average DC is 0.9 × RMS, from a plain transformer winding. Use this when you can.

Draw a rectifier as a triangle pointing the way current (conventional current, + to −) can flow, with a bar across its point. The bar end is the cathode; in a bridge, the two cathodes joined together are the + output.

Charging a battery is different

A battery pushes back with its own voltage. Current flows only during the part of each half-cycle when the AC voltage rises above the battery's voltage plus the rectifier's own loss. So:

  • The transformer must give a peak voltage well above the battery's — for a 12 V battery (6 lead-acid cells), a secondary of about 15–18 V RMS (peaks of 21–25 V) suits a bridge.
  • Something must limit the current, or it rushes in at the peaks and burns the rectifier: a series resistance, such as a lamp, a coil of iron wire, or the resistance of the transformer itself. Adjust it until an ammeter shows the right charging current — about a tenth of the battery's capacity in amps (The Rechargeable Battery, Measuring Electricity).
  • The battery itself smooths the pulses, so a charger needs no smoothing capacitors.

What you need

Item Use Notes
Transformer Steps mains AC down to the voltage you need The Transformer
Ammeter and voltmeter Setting the current; checking polarity Measuring Electricity
Ballast Lamps of known watts, or an adjustable coil of iron wire The Light Bulb, Copper Wire
Fuses One in the AC side, one at the battery Wiring and Electrical Safety
For electrolytic rectifiers Pure aluminium sheet, lead or iron sheet, borax or washing soda, rain water, glass or glazed jars Aluminium, Lead, Soda Ash and Baking Soda
For a vibrating rectifier Spring-steel strip, a permanent magnet, an electromagnet coil, silver or tungsten contacts Springs, Magnets, The Electromagnet
For a motor-generator An AC motor and a DC dynamo of similar size The Electric Motor, The Generator
For copper-oxide discs Copper sheet, a furnace, lead foil Semiconductors and the Transistor

Where to find it

  • Aluminium is made from bauxite — a soft, reddish-brown to cream rock of rounded grains, found under tropical soils — by electrolysis (Aluminium). It must be pure: aluminium alloys and scrap with copper or iron in them do not form a good blocking film.
  • Borax: white crusts and crystals on the beds of dried salt lakes in deserts (Tibet, Turkey, California); it froths up and melts to a clear glass in a flame (Soda Ash and Baking Soda, Glazes). Washing soda (sodium carbonate) from plant ash or the Leblanc and Solvay processes (Soda Ash and Baking Soda).
  • Lead from galena (Lead); copper from native copper and its ores (Copper Smelting).
  • Red cabbage juice makes a polarity-test paper (Acids, Bases and Testing).

Method 1: The motor-generator (most reliable)

If you already have an AC motor and a DC The Generator (dynamo), you already have a rectifier: let the motor turn the dynamo. This was how garages, telegraph offices and electroplating shops made DC from AC mains for decades.

  1. Mount the motor and dynamo on one heavy timber or iron base, shafts lined up, joined by a flexible coupling (a leather disc bolted between two flanges) or by a belt (Belts, Chains and Power Transmission).
  2. Match the speeds. The dynamo must turn at its rated speed. Choose pulley sizes: dynamo pulley × dynamo speed = motor pulley × motor speed.
  3. Wire a field rheostat — an adjustable resistance in the dynamo's field coil. It lets you set the DC voltage exactly, from zero up, and so control the charging current smoothly. Add a cut-out (a relay that disconnects the battery when the dynamo slows) so the battery cannot drive the dynamo as a motor (Wind Turbines describes one).

It is heavy and has two machines to maintain, and it gives back only 60–80% of the power. But it handles any current your machines can carry, gives clean DC, and needs no new materials.

Method 2: The vibrating reed rectifier

A vibrating rectifier is a switch that opens and closes in step with the AC, so it connects only during the forward half of each cycle.

The vibrating reed rectifier Magnetgives the reed a pole Spring-steel reed tuned to swing at the mains frequency Contactsilver or tungsten,adjusting screw swings Electromagnetpulls the reed down onone half-cycle, pushesit up on the nexta few volts AC ballast lamp + battery main transformer winding
Fig. 2 The vibrating reed rectifier. A magnetised steel reed swings over an electromagnet fed with a few volts of AC. On the forward half-cycle the coil pulls the reed down onto the contact and current flows through the lamp to the battery; on the backward half it pushes the reed up and the circuit is open.
  1. The reed: a strip of hardened spring steel about 12 cm long, 12 mm wide and 0.8 mm thick, clamped firmly at one end (Springs). Magnetise it, or fix a small permanent magnet to its clamped end so the reed carries a fixed magnetic pole (Magnets).
  2. The driving coil: an electromagnet with a soft iron core facing the free end of the reed, fed from a separate low-voltage winding of the transformer (a few volts AC). Because the reed already has a pole of its own, the coil attracts it on one half-cycle and repels it on the next. (An un-magnetised reed would be pulled on both halves and buzz at twice the mains frequency, which is useless.)
  3. Tune it. Slide the clamp or add a small brass weight to the reed's tip until it swings strongly and steadily at the mains frequency.
  4. The contact: a silver, tungsten or platinum point on the reed, and an adjustable screw with a matching point. Copper and brass points burn away in hours. Set the screw so the contact closes for only the middle part of the forward half-cycle — when the AC is well above the battery voltage — which cuts sparking. A capacitor of about 1 µF in series with 10–50 Ω across the contacts quenches sparks further (Resistors, Capacitors and Coils).
  5. Connect the main transformer winding, through the contacts and a ballast lamp, to the battery. If the battery is charged the wrong way, turn the reed's magnet round (or swap the coil leads).

Vibrating rectifiers charged car batteries in the early 1900s. They are quick to build from a magnet, a spring and a coil, and lose very little power, but the contacts wear and need cleaning and resetting every few weeks. Use two contacts on either side of the reed with a centre-tapped transformer for full-wave.

Method 3: The aluminium electrolytic rectifier

Aluminium in a borax or phosphate solution grows an invisibly thin skin of oxide (the same skin that Anodising Aluminium and Titanium grows thick on purpose) that lets current pass into the aluminium from the solution but blocks it the other way. A jar of it is a rectifier with no moving parts and no vacuum. It wastes some power as heat, but anyone can build it.

One jar 1–2 litres, borax in rain water Aluminium + out Lead from AC wax collarat waterline current passes only lead → aluminium; keep below 40 °C, 40 V per jar Four jars in a bridge, charging a battery AC transformer − + each arm = one jar; bar = aluminium end ammeter ballastlamp 12 V A set the lamps for about a tenth of the battery's capacity in amps
Fig. 3 The electrolytic rectifier. Left: one jar — a plate of pure aluminium and a plate of lead in a strong borax solution. Current can pass only from the lead, through the solution, into the aluminium. Right: four jars in a bridge charging a battery through a ballast lamp and an ammeter.
  1. The jar: glass or glazed stoneware, 1–2 litres. Wax the rim so the electrolyte does not creep out.
  2. The electrolyte: dissolve as much borax as will go into hot rain water or distilled water, let it cool, and use the clear liquid. Ammonium phosphate is better if you have it; washing soda or baking soda also work. No salt and no tap water with chloride in it — chloride eats through the oxide film.
  3. The plates: one of pure aluminium, one of lead (or iron). Allow at least 50–100 cm² of aluminium under the liquid for each ampere — about the area of a palm. Keep the plates 1–2 cm apart, held in a wooden or ebonite lid (Rubber). Only the immersed part matters; cover the aluminium where it passes through the liquid surface with wax or rubber tube, because the film fails first at the waterline.
  4. Form the film. Connect the jar in series with a 40–60 W lamp across the transformer's output (no battery yet). At first the lamp glows brightly. Over 10–30 minutes it dims as the film grows; the jar fizzes gently. When it settles, the jar is formed.
  5. Voltage. One jar blocks safely only about 40 V AC. For more, put jars in series.
  6. Build a bridge of four jars for full-wave, as in the figure. The aluminium ends of two jars, joined, are the + DC output; the lead ends of the other two, joined, are the − output.
  7. Keep it cool. The jars warm as they work and leak more current backwards when hot. Keep them below about 40 °C — warm to the hand, never hot. Use big jars, stand them in a tray of water, and top up with clean water as it evaporates.

Expect to get 60–75% of the power through. The aluminium wears slowly; replace plates when they are deeply pitted. Disconnect the battery when the AC is off — a resting jar slowly lets the battery leak back through it.

Method 4: Copper-oxide and selenium stacks

Copper oxide. Discs of copper with a thin red layer of cuprous oxide grown on one face, stacked with lead foil, conduct one way only. How to make them is in Semiconductors and the Transistor. In use:

  • Each disc blocks only a few volts — roughly 5 V at best, often less (Semiconductors and the Transistor); stack one disc for every 3–5 V of the peak voltage it must stand, in each arm of the bridge, and test the stack before trusting it. A 12 V charger needs about 4–6 discs per arm.
  • A disc 4 cm across passes a few hundred milliamps; put stacks in parallel, or make bigger discs, for more. Fit thin copper cooling fins between discs.
  • They last for years with no care, and do not leak much backwards when the AC is off. They were the standard battery charger and meter rectifier of the 1930s.

Selenium. An iron or aluminium plate coated with a thin film of grey selenium, heat-treated at about 200 °C to make it crystalline, and covered with a sprayed layer of low-melting alloy, blocks about 20 V per plate — four times a copper-oxide disc — and handles more current per area. Selenium is recovered from the slime left when copper is refined by electrolysis, and from the mud in lead-chamber sulfuric acid plants (Sulfuric Acid, Selenium and Tellurium). It is poisonous; treat this as a later, factory-scale step.

Method 5: Hot-cathode tubes

A heated filament in a vacuum gives off electrons, and current can flow only from a positive plate to the filament — the vacuum diode described in The Vacuum Tube (see also Power Supplies and Regulators). A vacuum diode carries tens of milliamps: ideal for radio plate supplies, weak for charging batteries.

For heavy, low-voltage currents, fill the bulb with a little argon at low pressure: a glowing tungsten filament and a graphite plate in argon pass several amps with a loss of only about 10 V. This gas-filled rectifier was the standard garage battery charger from about 1920 until selenium replaced it. Argon comes from liquefied air (Liquid Air, Nitrogen and the Noble Gases). The mercury-arc rectifier, a glass or steel tank with a pool of mercury as its cathode, handled hundreds of amps for railways and electrolysis plants; it is a factory project and mercury vapour is poisonous (Mercury).

Step by step: a battery charger from AC mains

  1. Plan. For a 12 V, 50 Ah battery, aim for about 5 A. Choose a transformer giving 15–18 V RMS at 5 A or more, and a bridge rated for 5 A and at least 30 V peak.
  2. Wire it: AC supply → fuse → transformer primary. Secondary → bridge AC terminals. Bridge + → ammeter → ballast (lamps in parallel or a coil of iron wire with a sliding clip) → fuse → battery +. Battery − → bridge −.
  3. Check polarity before connecting the battery. Touch the two output wires to a strip of paper wetted with red cabbage juice and a pinch of salt: the paper turns green or yellow at the negative wire (it makes alkali there). Or dip both wires in salty water: the wire that bubbles more is negative.
  4. Start with all the ballast in (high resistance, few lamps). Connect the battery, switch on, and watch the ammeter. Reduce the ballast until it reads about 5 A.
  5. Watch it. After 15 minutes feel the rectifier and the ballast; they may be warm, not too hot to touch. Watch the battery gas and read its hydrometer as in The Rechargeable Battery; as it charges, the current falls a little on its own.
  6. Finish: switch off the AC before disconnecting the battery, so the spark is not at the battery, where hydrogen collects.

How to tell it worked

  • Galvanometer test. A galvanometer on raw AC shivers around zero; on rectified current its needle swings steadily one way (Measuring Electricity).
  • Lamp test. A lamp in series with a single rectifier on AC glows noticeably dimmer than without it (half the power), and flickers.
  • Reverse test. Connect a charged battery to the rectifier the wrong way round, through an ammeter, with the AC off. A good rectifier lets through almost nothing — a few milliamps at most.
  • The battery charges: rising hydrometer readings and voltage, and gassing at full charge.

Note Troubleshooting. Battery charges backwards (voltage falls) → polarity reversed; swap the battery leads at once, or turn the reed's magnet round. Electrolytic jar gets hot and lamp stays bright → film not formed, aluminium impure, chloride in the water, or too many volts per jar. Re-form, use pure aluminium and rain water, add jars in series. Little or no charging current → transformer voltage too low for the battery; too much ballast; or the bridge has one arm reversed (the output is then shorted on one half-cycle — check each arm). Vibrator buzzes but does not charge → reed not magnetised (it is pulled on both half-cycles), or not tuned to the mains frequency, or contacts dirty. Heavy sparking → contact closing too early; open the gap a little, clean the points, fit the spark capacitor. Copper-oxide stack runs hot → overloaded or too few discs for the voltage; add discs or fins. Battery flat after the charger was off overnight → rectifier leaking backwards; disconnect the battery when not charging.

Dangers

Danger Mains AC kills. The primary side of the transformer, and any rectifier working at more than about 50 V, can drive a deadly current through your body. Build and change connections only with the supply disconnected at the plug or switch, enclose every terminal, and fuse the primary (Wiring and Electrical Safety). High-voltage supplies for radio tubes (hundreds of volts) keep their charge in their capacitors after switching off; drain them through a bleeder resistor before touching anything (Amplifiers and Oscillators).

Danger Charging batteries give off hydrogen, which explodes with a spark — and vibrating contacts, loose clips and electrolytic jars all make sparks or gas. Keep the rectifier away from the battery, ventilate the room, and switch off the AC before connecting or disconnecting the battery (The Rechargeable Battery).

  • Electrolytic jars warm, gas a little and contain alkaline salts; wear eye protection when filling them and keep them where they cannot be knocked over.
  • Overheated selenium rectifiers give off a foul, poisonous smoke; if one smells, switch off and ventilate.
  • Mercury-arc rectifiers contain poisonous mercury (Mercury).

What this unlocks

With a rectifier, AC from a Water Turbines and Hydroelectric Power, The Generator or Power Lines and Distribution can charge storage batteries for light and radio (Storing Energy), run Electrolysis and Electroplating baths, make Aluminium and Chlorine and Bleach, drive The Telegraph and The Telephone circuits, and power Radio transmitters and receivers. Silicon diodes (Semiconductors and the Transistor, Pure Silicon) later replace all of these in a tiny package.

How it was first done

The first rectifier was mechanical: in 1832 the Paris instrument maker Hippolyte Pixii, at André-Marie Ampère's suggestion, fitted a switching commutator to his hand-cranked generator so that its output flowed one way (The Generator). In 1857 the German chemist Heinrich Buff noticed that aluminium in solution passes current one way much better than the other. In the 1890s Karl Pollak and Leo Graetz used aluminium cells for rectifying and described the four-arm bridge that still bears Graetz's name; in the early 1900s the French engineer Albert Nodon sold electrolytic "valves" for charging batteries.

Peter Cooper Hewitt in the United States developed the mercury-arc rectifier around 1902; John Ambrose Fleming patented the vacuum diode in 1904. Gas-filled hot-cathode chargers were introduced by General Electric in the late 1910s. In 1926–27 Lars Grondahl and Paul Geiger at Westinghouse announced the copper-oxide rectifier, and selenium rectifiers followed in the 1930s; both were replaced by silicon diodes from the 1950s.

Source: content/entries/electricity/rectifiers.md