Part 15 · Knowledge and Science
Strength of Materials
How to work out, before you build, whether a beam, post, rod or rope will carry its load — with stress and strain, the bending of beams, buckling, and safety factors — and how to test timber, stone and metal yourself. It turns guesswork into bridges, roofs and machines that stand.
- Difficulty
- ●●●●●
- Time
- An evening to learn the formulas; a week to build a lever testing rig and test your local timbers and stones
- Steps from zero
- 6 prerequisites →
This unlocks
Trusses and FramesObjects made here
lever testing rigThe full path from nothing — 6 steps before this one
- Writing and Numbers
- Measurement from Scratch
- The Scientific Method
- Arithmetic and Fractions
- Forces, Energy and Heat
- Algebra
- Strength of Materials
Do them roughly in this order. See it on the tech tree →
Why it matters
Builders of old learned how big to make a beam by building, watching what broke, and copying what did not. It worked, slowly, at the price of many collapses — and it fails completely the moment you try something new: a longer span, a new metal, a machine that moves.
With a little algebra (Algebra) and a few measured numbers for your own materials, you can calculate instead:
- How deep a floor joist must be to carry a room full of people (Timber Framing and Log Building, Roofs).
- How thick a post, a stone pillar or a wall must be (Stone Masonry, Foundations and Floors).
- Which rope or chain is safe for a crane, a well or a ferry (Cranes and Lifting, Ropewalks and Sailcloth).
- How thick the shaft of a waterwheel, the bolts of an engine, or the plates of a boiler must be (The Waterwheel, The Steam Engine, Boilers and Pressure Vessels).
- How to use less material where it does nothing — which matters greatly when every kilogram of iron is smelted by hand (Iron (the Bloomery)).
How it works
Stress and strain
Pull on a rod. Every square millimetre of its cross-section carries a share of the force. That share is the stress:
Stress = force ÷ area, in newtons per square millimetre (N/mm²). One N/mm² is also called one megapascal (MPa).
(A force of 1 newton is the weight of about 100 grams; a 1 kg mass weighs 9.8 N — see Forces, Energy and Heat.)
Example. An iron rod 10 mm across holds up 1 tonne. Area = π × 5² = 78.5 mm². Force = 1,000 × 9.8 = 9,800 N. Stress = 9,800 ÷ 78.5 = 125 MPa.
The rod also stretches a little. The stretch divided by the original length is the strain. Up to a limit, strain is proportional to stress (Robert Hooke's law of 1678): double the load, double the stretch, and when the load comes off the rod springs back. The ratio is Young's modulus, E — the stiffness of the material:
E = stress ÷ strain
Steel has E ≈ 200,000 MPa; timber along the grain about 10,000 MPa — twenty times less stiff. The 125 MPa iron rod above, 2 m long, stretches 125 ÷ 200,000 × 2,000 mm = 1.25 mm.
Beyond the straight part of the curve:
- Ductile materials (mild steel, wrought iron, copper) reach the yield point, after which they stretch a lot and stay bent. They bend before they break — a visible warning.
- Brittle materials (cast iron, stone, brick, glass, hardened steel) snap with almost no warning. Use them only in compression, where they are strong, and give them bigger safety factors.
Tension, compression and shear
- Tension: pulling — ropes, tie-rods, the bottom of a beam.
- Compression: pushing — posts, walls, arches, the top of a beam. Stone and cast iron are many times stronger in compression than in tension, which is why masonry builds in arches (Arches, Vaults and Domes).
- Shear: one part sliding past another — a bolt across a joint, a pin in a hinge, the grain of timber splitting along a notch.
Bending
A beam loaded from above sags. Its top is squeezed, its bottom is stretched, and somewhere in the middle runs a line that is neither — the neutral axis. The stresses are biggest at the top and bottom faces.
The turning effect of the loads on a beam is the bending moment, M (force × distance, in N·mm). It is greatest in the middle of a simply supported beam:
| Beam | Largest bending moment | Largest sag |
|---|---|---|
| Resting on two supports, load W at the middle, span L | M = W L ÷ 4 | W L³ ÷ (48 E I) |
| Two supports, load W spread evenly | M = W L ÷ 8 | 5 W L³ ÷ (384 E I) |
| Cantilever (fixed at one end), load W at the free end | M = W L | W L³ ÷ (3 E I) |
The beam resists with its section modulus, Z, and its stiffness with its moment of inertia, I. For a rectangle b wide and d deep:
Z = b × d² ÷ 6 I = b × d³ ÷ 12 Bending stress = M ÷ Z
For a round bar of diameter D: Z = π D³ ÷ 32 and I = π D⁴ ÷ 64.
The great lesson: depth matters most. Turn a 50 × 150 mm plank from flat to on edge and its strength rises 3 times and its stiffness 9 times. Always put joists, rafters and lintels on edge. A beam twice as deep is 4 times as strong and 8 times as stiff.
Buckling
A short, thick post fails by crushing. A long, thin one fails long before that by buckling — bowing sideways and collapsing. Leonhard Euler worked out in 1744 the load at which a slender post with pinned ends buckles:
Buckling load = π² × E × I ÷ L²
Double the length, and the buckling load falls to a quarter. Brace long posts in the middle, or make them thicker.
What you need
| Item | Use |
|---|---|
| A table of materials (below) — then your own test results | Strengths and stiffness |
| Measuring rule, calipers (Measurement from Scratch) | Sizes of members |
| A testing rig: a stout lever, a bucket, sand or water, a weighed set of stones (Simple Machines) | Testing your own materials |
| Notebook | Every test written down, with date, source of timber, moisture, result (The Scientific Method, Statistics and Probability) |
Strengths of common materials
Typical values for good, dry material (more in Materials Data Tables). Your own material may be very different — test it.
| Material | Breaking stress in tension (MPa) | Crushing stress (MPa) | Stiffness E (MPa) | Safe working stress for design (MPa) |
|---|---|---|---|---|
| Softwood (pine, spruce), along grain | 80–100 (clear wood) | 35–45 | 9,000–12,000 | 6 in bending, 5 in compression |
| Oak, dry, along grain | 90–110 (clear wood) | 45–55 | 10,000–12,000 | 8 in bending, 7 in compression |
| Granite | 7–20 | 100–250 | 50,000 | 4 in compression; none in tension |
| Limestone, sandstone | 2–10 | 20–150 (very variable) | 20,000–50,000 | 1.5–3 in compression |
| Fired brick in lime mortar (as a wall) | almost none | 3–10 | 5,000 | 0.4–1 |
| Concrete, well made (Portland Cement) | 2–4 | 20–40 | 25,000 | 7 in compression; reinforce for tension (Reinforced Concrete) |
| Cast iron | 150–250 | 600–900 | 100,000–120,000 | 25 in tension, 100 in compression |
| Wrought iron | 300–370 | (yields at 200) | 190,000 | 80 |
| Mild steel | 400–550 | (yields at 250) | 200,000 | 150 |
| Copper, annealed | 210–250 | — | 117,000 | 50 |
The "safe working stress" already includes a safety factor for steady loads on sound material.
Safety factors
Why not design right up to the breaking stress? Because the material may have a hidden knot or crack, the load may be bigger than you thought, it may be applied with a jerk, and things rot, rust and wear. A safety factor is the breaking load divided by the load you intend.
| Situation | Safety factor on breaking strength |
|---|---|
| Steel or wrought iron, steady loads you know well | 3–4 |
| Timber, steady loads | 4–6 (already in the working stresses above) |
| Brittle materials — cast iron, stone, brick, glass | 6–10 |
| Moving machinery, shock and vibration | Double the above |
| Ropes and chains lifting goods | 5–6 |
| Anything that carries or lifts people | 10 or more |
| Boilers and pressure vessels | 5–6, plus a water-pressure test before use (Boilers and Pressure Vessels) |
Worked examples
1. A floor joist
A room 4 m wide. Joists span the 4 m, spaced 60 cm apart. Floor load: people, furniture and the floor itself, take 2.5 kN per square metre (about 250 kg/m² — a crowded room).
- Each joist carries a strip 0.6 m wide: 2.5 × 0.6 = 1.5 kN per metre, or 1.5 N per mm. Total W = 1.5 × 4,000 = 6,000 N, spread evenly.
- M = W L ÷ 8 = 6,000 × 4,000 ÷ 8 = 3,000,000 N·mm.
- Softwood safe bending stress 6 MPa, so Z must be at least 3,000,000 ÷ 6 = 500,000 mm³.
- Try b = 75 mm: d² = 6 × 500,000 ÷ 75 = 40,000, so d = 200 mm.
- Check the sag. I = 75 × 200³ ÷ 12 = 50,000,000 mm⁴. Sag = 5 × 6,000 × 4,000³ ÷ (384 × 10,000 × 50,000,000) = 10 mm. A floor should sag no more than span ÷ 300 = 13 mm. ✓
Answer: 75 × 200 mm softwood joists at 60 cm centres. (The rule of thumb: depth in mm ≈ 50 × span in metres.)
2. A timber post
A softwood post 100 × 100 mm, 3 m tall, ends free to turn. I = 100⁴ ÷ 12 = 8,330,000 mm⁴.
- Crushing would need 100 × 100 × 40 = 400,000 N (about 40 tonnes).
- Buckling happens at π² × 10,000 × 8,330,000 ÷ 3,000² = 91,000 N (about 9 tonnes) — far less.
- With a safety factor of 3, the post may carry 3 tonnes. Brace it halfway up in both directions and the buckling length halves, so its safe load rises to about four times as much — then crushing, not buckling, becomes the limit.
3. A stone pillar
A granite pillar 30 × 30 cm carries 50 tonnes. Stress = 50,000 × 9.8 ÷ (300 × 300) = 5.4 MPa. Granite crushes at 100 MPa or more: a factor of about 20. Safe — provided the load comes straight down. Stone in bending (as a lintel) is another matter; keep stone lintels short (under about 1.5 m) and deep (at least a fifth of their span), or use an arch.
4. A rope
Good new hemp or manila rope breaks at roughly 6 × d² kilograms, where d is its diameter in millimetres (12 mm rope: about 860 kg). To lift 300 kg of stone with a safety factor of 6, you need a rope that breaks at 1,800 kg: d = √(1,800 ÷ 6) ≈ 18 mm. Old, wet, knotted or sun-rotted rope may have half that strength or less; a knot alone weakens a rope by a third or more (Cordage and Rope).
Testing your own materials
Tables are a start; your timber, from your forest, dried your way, may be much weaker or stronger. Test it.
The lever rig
- Take a stout, straight hardwood beam about 2.5 m long. Pivot it on a strong iron pin through a post, with 0.2 m on the short side and 2.0 m on the long side: a 10 : 1 lever (Simple Machines).
- Anchor the specimen from a ring in a heavy stone or a post in the ground up to the short arm (for pulling tests), or set a bending specimen on two supports under the short arm (for bending tests).
- Hang a bucket on the long arm. Pour sand slowly until the specimen breaks. Weigh the bucket and sand.
- Force on the specimen = (bucket + sand) × 10, plus a correction for the lever's own weight (find it by weighing the long end resting on a balance).
Tension test: wire
Example. An iron wire 2.0 mm across breaks with 11.5 kg in the bucket. Force = 115 kg × 9.8 = 1,127 N. Area = π × 1² = 3.14 mm². Breaking stress = 1,127 ÷ 3.14 = 359 MPa — good wrought iron (Iron and Brass Wire).
Stiffness. Hang a 2 m length of the wire from a beam. Fix a light pointer lever at the bottom whose long arm is 20 times its short arm, so it magnifies the stretch 20 times. Add 20 kg: stress = 196 N ÷ 3.14 = 62 MPa. If the pointer moves 12.5 mm, the real stretch is 0.62 mm; strain = 0.62 ÷ 2,000 = 0.00031; E = 62 ÷ 0.00031 ≈ 200,000 MPa.
Bending test: timber
Example. A clear pine stick 20 × 20 mm, on supports 1 m apart, with 10 kg (98 N) hung at the middle, sags 15 mm.
- I = 20 × 20³ ÷ 12 = 13,330 mm⁴.
- E = W L³ ÷ (48 × sag × I) = 98 × 1,000³ ÷ (48 × 15 × 13,330) ≈ 10,200 MPa.
Load it further until it breaks — say at 43 kg (422 N). M = 422 × 1,000 ÷ 4 = 105,500 N·mm; Z = 20 × 20² ÷ 6 = 1,333 mm³; breaking stress = 79 MPa.
Test at least five or ten pieces and use the lowest results, not the average (Statistics and Probability). Divide by 4–6 for a working stress, and lower still for knotty wood.
Compression test: brick and stone
Cut cubes 4 cm on a side, faces ground flat and parallel. Crush them between two flat iron plates under the lever's short arm, set with a packing of thick leather or lead sheet. A 4 cm cube of good brick at 20 MPa needs 1,600 × 20 = 32,000 N — about 3.3 tonnes, or 330 kg of sand on a 10 : 1 lever. Use a 20 : 1 lever, or a big screw press (Screws, Nuts and Bolts).
Proof testing
Before using any chain, hook, rope or lifting beam, load it once to twice its working load (never near breaking) and inspect it for cracks, stretch or bending. Proof-test boilers with water pressure, never air.
Rules of thumb
- Depth is everything in a beam. Strength grows with depth², stiffness with depth³.
- Span is the enemy. Double the span of a beam and, for the same sag, it carries only an eighth as much spread load.
- Floor joists: depth (mm) ≈ 50 × span (m), 50–75 mm thick, at 40–60 cm centres, softwood.
- Never notch the bottom of a beam in mid-span: that is where it is stretched hardest. Drill any holes through the middle of the depth, near the supports.
- Timber in damp places has only about two-thirds of its dry strength, and rots (Rot, Woodworm and Termites). Straight grain matters: a slope of grain steeper than 1 in 10 makes timber much weaker.
- Timber and lead creep: under a load that never comes off, they keep sagging for years. Design permanent loads with extra margin.
- Posts: if the height is more than about 25 times the thinnest side, buckling, not crushing, decides; brace it.
- Masonry walls taller than about 12 times their thickness need buttresses or cross walls.
- Round off inside corners in metal parts with as large a radius as you can. Sharp corners, scratches and screw threads concentrate stress; in shafts and machines that turn or shake, cracks grow from them over months — fatigue. For anything that vibrates, keep stresses below a third of the breaking stress.
- Heat: steel loses about half its strength by 600 °C (dull red) — in a fire, iron beams sag and fall (Firefighting).
- Cold and shock: cast iron and some steels become brittle in frost; never hammer cast iron parts in the cold.
How to tell it worked
- Calculated sag matches measured sag on a real beam under a known load, within about 20%. If it sags much more, your E is wrong or the joints are slipping.
- Proof tests pass without permanent bending.
- Structures do not creak, crack or keep sagging after the first months. Mark the middle of an important beam against a string line and check it once a season.
Note Troubleshooting your calculations. Answer wildly too big or small → check units: everything in newtons and millimetres gives stresses in MPa. Mixing metres and millimetres is the commonest mistake by far. Beam strong enough but bouncy → stiffness, not strength, rules; make it deeper. Test pieces give scattered results → normal for timber and stone; test more and use the lowest. Specimens break in the grips → make the ends wider than the middle (a "dog-bone" shape) so the break comes in the measured part.
Dangers
Danger Test rigs store energy. A rope, wire or chain that snaps under load whips back and can blind or kill; brittle stone and cast iron burst into flying fragments. Stand to the side, never in line with the specimen; drape heavy sacking over it; wear eye protection; never put your hand or head under the loaded lever.
Danger Never stand under a suspended load or a structure being tested, and never test a building by loading it with people. Calculation and proof tests come first; people come last.
- A calculation is only as good as its assumptions. The wrong load, a forgotten wind or snow load, a rotten timber, or one slip with units can bring a roof down. Have a second person check important calculations independently (Technical Drawing).
- Old structures lose strength to rot, rust and cracks. Inspect them every year.
Going further
- Trusses: triangles of members in pure tension and compression carry long spans with little material (Trusses and Frames, Roofs, Roads and Bridges).
- Steel frames and reinforced concrete extend these methods to tall buildings (Steel Frames and Tall Buildings, Reinforced Concrete).
- Shafts in twisting for mills and engines (The Waterwheel, Belts, Chains and Power Transmission).
- Pressure vessels: the stress in a thin cylinder wall is pressure × diameter ÷ (2 × thickness) — the basis of boiler design (Boilers and Pressure Vessels, Pressure Vessels and Valves).
- Earthquakes and wind demand ductile materials and good joints (Building Against Earthquakes and Storms).
How it was first done
Around 1500 Leonardo da Vinci sketched a test of iron wire, with a basket slowly filled with sand until the wire broke. In 1638 Galileo Galilei, in his Two New Sciences, set out the first theory of the strength of beams, and noticed that bigger animals need proportionally thicker bones. Robert Hooke published his law of springs in 1678. Leonhard Euler found the buckling load of columns in 1744. Charles-Augustin de Coulomb in 1773 correctly placed the neutral axis of a beam and studied soil and masonry. Thomas Young defined the modulus of stiffness in 1807, and Claude-Louis Navier in Paris drew it all into the beam theory engineers use, in 1826. Practical testing grew with the railways: Eaton Hodgkinson and William Fairbairn tested model tubes to design the Britannia Bridge across the Menai Strait (1850), and in 1866 David Kirkaldy opened a public testing works in London with a giant hydraulic machine and the motto "Facts not opinions".