Part 9 · Health and Medicine
Airway Equipment: Laryngoscopes and Tubes
An unconscious person's tongue falls back and blocks the throat within seconds, and a blocked airway kills faster than anything else in medicine. The simple airways that hold the throat open, the lighted laryngoscope and the tubes it places, the suction that clears vomit and blood, and the tracheostomy tube for the long haul — with the sizes, and the honest truth about how much practice each one needs.
- Difficulty
- ●●●●●
- Time
- An afternoon for an oral airway; a week for a laryngoscope; months of supervised practice before intubating a living patient
- Steps from zero
- 62 prerequisites →
This unlocks
—The full path from nothing — 62 steps before this one
- Fire
- Stone Tools
- Cordage and Rope
- Finding and Preparing Clay
- Finding and Identifying Ores
- Sulfur
- How the Body Works
- Basic Woodworking
- Hunting and Trapping
- Pottery
- The Kiln
- Charcoal
- Examining a Patient
- Hides and Leather
- Lime
- Salt
- Bricks
- Mercury
- Fermentation
- Lye and Potash
- The Wheel and Axle
- Glass
- Firebrick and Refractories
- Bellows
- Distillation
- Saltpeter
- The Lathe
- Gears
- Iron (the Bloomery)
- Copper Smelting
- Sulfuric Acid
- Laboratory Glassware
- Pumps
- The Waterwheel
- Blacksmithing
- The Blast Furnace and Cast Iron
- Ether, Acetone and Solvents
- The Battery
- Magnets
- The Barometer
- Steel
- Sheet Metal and Rolling
- Anaesthesia
- The Steam Engine
- Bellows to Air Compressors
- Electrolysis
- Copper Wire
- Hydrogen, Oxygen and Gases
- Machine Tools
- Boilers and Pressure Vessels
- The Generator
- The Electric Arc Furnace
- Ammonia
- Ice and Refrigeration
- Calcium Carbide and Acetylene
- Welding
- Liquid Air, Nitrogen and the Noble Gases
- Metal Pipes and Tubes
- Pressure and Vacuum Gauges
- Pressure Vessels and Valves
- Medical Oxygen
- Breathing Machines and Ventilators
- Airway Equipment: Laryngoscopes and Tubes
Do them roughly in this order. See it on the tech tree →
Why it matters
A person whose airway is blocked has about four minutes, the same as one whose heart has stopped, and airway blockage is far commoner. It happens to anyone deeply unconscious — head injury, a fit, a stroke, poisoning, drink, a diabetic coma, the ether in Anaesthesia: the muscles that hold the throat open let go and the tongue falls back against the throat wall like a flap valve.
The first and best treatment costs nothing: tilt the head back, lift the chin, push the jaw forward, and roll the patient on their side (Emergencies, The First Aid Kit). The equipment here is for when hands alone are not enough:
- an oral or nasal airway to hold the throat open with no one holding the jaw;
- a suction pump to get vomit, blood and secretions out before they drown the patient;
- a laryngoscope and endotracheal tube to seal the windpipe off from the stomach and let a machine breathe for the patient (Breathing Machines and Ventilators);
- a tracheostomy tube for the patient who will need an artificial airway for weeks.
Danger Everything in this chapter can kill in untrained hands. A tube in the gullet instead of the windpipe is fatal within minutes unless found; an oral airway pushed into a half-conscious patient makes them vomit and inhale it; suction applied too long drops a sick patient's oxygen to nothing. Practise for months on dead animals and on models before using any of it on a patient. Someone who can hold a jaw and use a bag and mask saves more lives than someone who can only intubate.
How the airway blocks, and what each device does
Air passes from nose and mouth into the pharynx (the chamber behind the tongue), then through the larynx (the voice box, guarded by the vocal cords) into the trachea or windpipe, a tube of cartilage rings about 2 cm across and 11 cm long in an adult. Behind the larynx lies the oesophagus (gullet) (How the Body Works). Three things go wrong:
- The tongue falls back and closes the pharynx. Airways hold it forward or bypass it.
- Stuff gets in: vomit, blood, teeth, saliva. Stomach acid in the lungs burns them and can kill days later. Suction and the cuffed tube deal with this.
- The larynx closes or swells: spasm, a burn, allergy, a growth, a wedged foreign body. Only a tube past it, or a hole in the windpipe below it, helps.
The signs of a blocked airway, in order of badness: snoring or gurgling (partly blocked); a crowing, high-pitched noise on breathing in (the larynx is narrowed); silence with the chest and belly heaving in opposite directions (completely blocked — a see-saw, where the belly rises as the chest sinks). Silence is the emergency. Blueness of the lips comes late.
What you need
| Thing | For | Chapter |
|---|---|---|
| Hard rubber (ebonite), or latex for dipping | Airways, tubes, cuffs | Rubber |
| Sheet steel 0.8–1.2 mm, or nickel silver | Laryngoscope blades | Sheet Metal and Rolling, Alloy and Stainless Steels |
| Silver, or silver-plated copper | Tracheostomy tubes, mouth airways | Gold and Silver, Electroplating |
| Small bulb, 2.5–3.8 V, and two dry cells | Laryngoscope light | The Light Bulb, Dry Cells and Electric Torches |
| A bellows or piston pump and two flap valves | Suction | Bellows, Pumps |
| Thick-walled glass jars with rubber bungs | Suction trap and collection | Bottles, Drinking Glasses and Glassware, Laboratory Glassware |
| Fine copper or aluminium wire, 2–3 mm | Stylets | Copper Wire |
| Woven cotton tubing, shellac or latex | Bougie | Spinning and Weaving Cloth, Glues and Adhesives |
| Steam steriliser, or a big pan | Cleaning everything | Sterilising Instruments and Dressings |
Rubber is the key material. Red rubber, latex dipped on a mandrel and vulcanised (Rubber), made every airway tube in the world until the 1970s: firm when cool, softening at body heat, surviving boiling and autoclaving for years. Clear plastic (Petrochemicals and Modern Plastics) is nicer but not needed.
The oral airway
What it is
An oral airway (Guedel airway) is a short, stiff, flattened tube curved like a shepherd's crook, lying over the tongue with its tip in the pharynx just above the larynx. It holds a channel open behind the tongue and doubles as a bite block — the most useful object in this chapter and the easiest to make. It has a flange at the mouth end so it cannot disappear inside, a stiff bite portion, and a smooth curved body with an oval channel through it.
Sizes
Size is by length, measured straight from flange to tip (makers' size numbers vary a little; go by the length):
| Size | Length | Patient |
|---|---|---|
| 000 | 30–40 mm | Small newborn |
| 00 | 40 mm | Newborn |
| 0 | 50 mm | Infant |
| 1 | 60 mm | Small child |
| 2 | 70 mm | Child, small adult |
| 3 | 80 mm | Average adult woman |
| 4 | 90 mm | Average adult man |
| 5 | 100 mm | Large adult |
Size it on the patient: hold it against the side of the face with the flange at the corner of the mouth; the tip should reach the angle of the jaw. Too short pushes the tongue back; too long presses on the larynx, causing retching or spasm.
Making one
- The best version: moulded hard rubber. Carve a former in close-grained hardwood or brass, shaped as the inside channel: an oval about 14 × 8 mm for a size 4, curved on a radius of about 45 mm through roughly a quarter circle. Build the body around it by dipping in latex and vulcanising, or by pressing unvulcanised hard rubber into a two-part mould and curing (Rubber, Presses, Punches and Dies). Wall 2–2.5 mm; flange an oval about 25 × 15 mm. Pull out the former, trim and polish.
- The metal version, like the first airways: two halves of 0.6 mm silver sheet or silver-plated copper formed over the same former, the seam soldered (Soldering and Brazing), filed dead smooth, with a flange soldered on. It lasts a lifetime but is hard on teeth; whip the bite portion with waxed thread.
- The emergency version: close-grained hardwood (box, maple, fruitwood) carved to shape, the channel bored through, sanded glass-smooth, sealed with shellac and boiled before use. Wood can split, but beats nothing.
Using it safely
Only in a patient who is deeply unconscious and does not gag. In an adult, insert it with the curve pointing to the roof of the mouth and rotate it 180° as it passes the tongue; in a child, insert it the right way up. Breathing should get quieter. If they gag, cough or strain, take it out at once.
The nasal airway
A nasal airway is a soft rubber tube passed through a nostril to the pharynx. A half-conscious patient usually tolerates it where an oral airway makes them retch, and it works through clenched teeth.
- Sizes: inside bore 6 mm (average woman) or 7 mm (average man); 3–5 mm for children. Length: measure from the nostril to the earlobe, usually 14–16 cm in an adult.
- Make it by dipping latex on a slightly tapered steel rod: wall about 1.5 mm, a smooth bevel at the far end, and a flange at the near end (or a safety pin through it) so it cannot slide inside the nose.
- Use it well lubricated (plain boiled vegetable oil or a water jelly), pushed straight back along the floor of the nose, not upwards. If it will not pass with gentle pressure, try the other nostril; never force it.
Warning Do not put anything up the nose of a patient with a serious head injury who has clear fluid or blood coming from the nose or ears, or bruising round both eyes: the base of the skull may be broken and the tube can enter the brain.
The laryngoscope
What it is
A laryngoscope is a lighted blade that lifts the tongue and jaw out of the way so you can see the vocal cords and pass a tube between them: in effect a specialised torch (Dry Cells and Electric Torches).
The two blades
- The curved blade (Macintosh pattern) is what to make first. Its tip goes into the vallecula, the gutter between the tongue and the epiglottis (the leaf of cartilage over the larynx), and lifting tips the epiglottis up. Lengths along the curve: size 2, 108 mm (child), size 3, 130 mm (most adults), size 4, 155 mm (large adults).
- The straight blade (Miller pattern) is slipped under the epiglottis itself and lifts it directly — better in babies, whose epiglotti are long and floppy. Lengths: 75–80 mm (newborn), 100 mm (infant), 155 mm (child to small adult), 190 mm (adult).
Making one
- The blade. Cut a blank from 1 mm stainless steel (Alloy and Stainless Steels) or nickel silver. The working part is a spatula about 20 mm wide, curved along its length through 30–40°, with a flange turned up along the left side 12–15 mm high to hold the tongue out of sight. Form it over a hardwood buck with a mallet (Sheet Metal and Rolling); blunt and thicken the tip; round every edge and polish mirror-bright (Precision Grinding).
- The light. Braze a clip into the flange about 25 mm back from the tip for a small screw-in bulb of 2.5–3.8 V (The Light Bulb); a white LED (Light-Emitting Diodes) runs cooler and lasts longer. Run one wire through an insulated tube inside the flange and use the blade as the return.
- The handle. A tube 28–32 mm across and 120 mm long holding two dry cells end to end, with a spring contact in the base cap (Dry Cells and Electric Torches).
- The hinge. A hook-on fitting: a 4 mm rod across the top of the handle, a hooked slot in the blade's heel, and a sprung phosphor-bronze contact so the lamp lights only when the blade is swung up to working position — switch and blade-changer in one.
Using it
Learn this at the elbow of someone who can already do it. In outline: lay the patient flat, head tipped back. Hold the laryngoscope in the left hand, insert the blade on the right side of the tongue and sweep the tongue to the left with the flange. Advance until you see the epiglottis, place the tip in the gutter in front of it, and lift up and away along the line of the handle — never lever back on the upper teeth, which breaks teeth and shows you nothing. You should see a triangle with the white vocal cords at its sides. Pass the tube from the right, watching its tip go between the cords.
If you cannot see them, improve the head position, press on the voice box from outside, suction, or change blade. If you still cannot, stop and ventilate with a bag and mask. Repeated attempts swell the throat and turn a difficult airway into an impossible one.
The endotracheal tube and its helpers
Breathing Machines and Ventilators gives the tube's sizes and how to dip one; here is what goes with it.
Check a tube before use: inflate the cuff with 10 mL of air for five minutes; it must not sag. Look down the bore for a collapsed wall. Bent right round, it should spring back without kinking. Sterilise it and let it cool, or it will be floppy.
The intubation stylet
An intubation stylet is a 2–3 mm malleable wire — soft copper or aluminium — pushed inside the tube to hold it in a chosen curve, usually a hockey-stick with the last 3 cm bent up by 35°. Coat it smooth with a dipped rubber sleeve and give it a stop at the outer end, so the tip cannot pass the end of the tube: a protruding stylet tears the windpipe. Withdraw it as soon as the tube's tip is through the cords.
The gum elastic bougie
A gum elastic bougie is the most valuable rescue device for a difficult airway, and easy to make: a flexible rod 60 cm long and 5 mm thick, the last 3.5 cm bent at about 35°. Make it from closely woven cotton braid drawn through hot shellac or latex, dried under slight tension, rolled smooth and cured: stiff enough to hold a curve, limp enough to follow the airway.
When you see only the epiglottis, pass the bougie blind under it, angled tip forward. In the windpipe you feel gentle clicks over the cartilage rings and it stops at 25–40 cm; in the gullet it slides in smoothly and endlessly. Then thread the tube over it.
Magill forceps
Magill forceps are angled grasping forceps about 25 cm long, the blades offset from the handles by two bends so your hand stays out of the line of sight, with oval, serrated, blunt jaws. They guide a tube tip towards the cords in nasal intubation and pull food, a tooth or a coin out of the throat under direct view (Medical Instruments).
Suction
What it is
A suction pump is a vacuum source, a trap jar that catches what you suck out, and a suction catheter or rigid tip at the patient's end. Without it, a patient who vomits under anaesthetic drowns in their own stomach contents.
Building one
- The vacuum source. A foot bellows (Bellows) with two flap valves of leather or thin rubber, one in the inlet from the trap jar and one in the outlet to the air; about 8 litres of stroke, worked twice a second. A treadle- or motor-driven piston pump (Pumps) does as well. A rubber bulb syringe with two valves is simplest of all and belongs in every first-aid kit.
- The trap jar. A thick glass jar of 1–2 litres, marked in 100 mL steps, with a rubber bung carrying two glass tubes: a long one reaching near the bottom for the patient's line, a short one to the pump.
- The safety trap. A second, smaller jar between trap and pump catches froth so liquid never reaches the pump.
- The patient's end. For mouth and throat, a rigid tip (Yankauer pattern) of 5–6 mm bore with a rounded, perforated end. For a tube or nose, a soft suction catheter of smooth rubber, 10–14 French (about 3.5–4.5 mm across), with a side eye near the tip and a thumb hole near the connector: suction works only while you cover the hole, so you can position it first.
- Tubing of at least 6 mm bore, or it will not pass a clot or a lump of food.
Numbers and rules
- Vacuum: for clearing vomit from an adult's mouth and throat with the rigid tip, up to 300–400 mmHg (roughly half a bar below atmosphere). Down a tube or into the windpipe, far less: below about 150–200 mmHg in an adult, 80–120 mmHg in a baby or child. Too much tears the lining of the throat and lungs. Fit a bleed valve (a screw that lets air in) to turn the vacuum down.
- Test it with water. Stand a long clear tube in a bucket of water and suck at its top: 150 mmHg of vacuum lifts water 2 metres, 300 mmHg lifts it 4 metres. A pump that will not raise water 4 m is leaking, usually at the bung.
- Time: never suck for longer than 10–15 seconds at a stretch, and give oxygen or breaths before and after: suction removes air too. A slowing pulse means stop at once.
- Clean everything after every use: boil the jar, flush the tubing with hot soapy then boiled water, boil catheters 20 minutes (Sterilising Instruments and Dressings).
The tracheostomy tube
What it is
A tracheostomy tube is a short, strongly curved tube that goes through a surgical opening in the front of the neck into the windpipe, bypassing mouth, nose and larynx. Use it when an artificial airway is needed for more than one to two weeks (an endotracheal tube ulcerates the larynx by then), when the larynx is blocked, or when the chest needs frequent suction.
The classic design, standardised by Chevalier Jackson around 1909, has three parts:
- The outer cannula, which stays in the hole, with a flat neck plate carrying two slots for cloth tapes tied round the neck.
- The inner cannula, a slightly smaller tube that drops inside and locks with a quarter turn. It can be taken out, cleaned of dried mucus and replaced in seconds without disturbing the airway — the whole point of the design.
- The obturator (introducer), a smooth-nosed plug used in place of the inner cannula while the tube is inserted, so a blunt end leads the way.
Sizes and making
| Part | Adult man | Adult woman | Child of 5 |
|---|---|---|---|
| Outer cannula, outside diameter | 10–11 mm | 9–10 mm | 6 mm |
| Inner cannula, bore | 8 mm | 7 mm | 4.5 mm |
| Length along the curve | 75–80 mm | 70–75 mm | 45 mm |
| Curve | about a quarter circle, radius 25–30 mm |
Make it in silver, or silver-plated copper, as the originals were: easily worked, takes a mirror polish, survives endless boiling. Roll sheet of 0.4–0.5 mm over a mandrel and silver-solder the seam (Sheet Metal and Rolling, Soldering and Brazing, Gold and Silver), bend it on the mandrel, file and polish the ends dead smooth, and silver-solder on the neck plate. The inner and outer must slide with a close but easy fit — lap them together with fine abrasive (Abrasives and Grinding Stones).
A patient on a ventilator needs a cuffed tube of rubber: dip latex on a curved mandrel as for an endotracheal tube (Breathing Machines and Ventilators), with a cuff near the tip and a fine inflation tube led out beside the neck plate. Cuff pressure 20–30 cmH₂O, no more.
The tracheal dilator
A tracheal dilator is a strong scissor-like instrument whose blunt blades open as the handles close. It holds the opening in the windpipe apart while the tube is slipped in, and it saves a patient whose fresh tracheostomy tube has fallen out and whose hole is closing. Forge it from tool steel, with blades 30 mm long turned slightly outward.
Keep at the bedside, always: a spare tube of the same size, one a size smaller, a tracheal dilator, tested suction, and a syringe to deflate the cuff (Nursing the Sick, Running a Hospital).
Warning Making the hole is surgery (Basic Surgery), done through the second and third cartilage rings of the windpipe by someone who knows the anatomy: the thyroid gland lies over it, large veins beside it, and bleeding into an open windpipe is lethal. When the larynx is completely blocked and nothing else works, a hole can be made through the cricothyroid membrane (the soft gap between the two hard lumps at the front of the throat) and a 6 mm tube put through. It is a last resort and must be practised beforehand on animal tissue.
How to tell it worked
For a simple airway: the noise stops, the chest rises evenly, colour improves. If the belly rises while the chest sinks, it is still blocked.
For an endotracheal tube — check all of these, every time:
- The chest rises on both sides when you squeeze the bag.
- Listen with a stethoscope (Examining a Patient) at five places: both armpits, both sides of the front of the chest, and over the stomach. Gurgling over the stomach with no breath sounds in the chest means the tube is in the gullet: take it out at once and start again with a bag and mask.
- Mist comes and goes in the tube with each breath.
- The bag feels like lung — a springy resistance — not like a bottomless bag or a brick wall.
- The colour and pulse improve rather than worsen.
- Write down the number at the teeth (21–23 cm in an adult) and check it hourly: tubes migrate.
For suction: the water-lift test, and a cup of thin porridge should vanish through the tubing in a few seconds.
Note Troubleshooting. Patient gags and vomits when the oral airway goes in → not deeply enough unconscious. Remove it, roll them on their side, suction, hold the jaw instead. Oral airway makes the breathing worse → too short, and it has pushed the tongue back. Remove and re-size. Laryngoscope bulb flickers → dirty hinge contact or weak spring; clean with spirit, bend the spring. Tape a spare bulb to the handle. Tube will not pass the cords although you can see them → too big; drop half a millimetre of bore. Never force it: the cricoid ring is the narrowest part, and forcing a tube through it in a child scars it permanently. Cuff hisses at every breath → under-inflated, split, or the tube is too small for the windpipe. Suction stops working → trap jar full, bung loose, tubing blocked by a clot, or the catheter's thumb hole uncovered. Tracheostomy patient suddenly distressed → pull the inner cannula out and look at it first; a plug of dried mucus is the commonest cause. If it is clear, the whole tube is blocked or displaced: deflate the cuff, be ready to remove it and ventilate through the mouth while an assistant brings the spare tube and the dilator.
Dangers
Danger An unrecognised misplaced tube is the deadliest event in medicine. A tube in the gullet, or one that slips out of the windpipe an hour later, gives no warning except the patient's colour. Confirm placement at insertion, after every move of the patient, and whenever anything changes. If in doubt, take it out and use a bag and mask: nobody dies of a removed tube; many have died of a kept one.
- Inhaled stomach contents. Fast the patient before planned anaesthesia, have suction tested and ready, and turn them on their side the moment there is trouble.
- Teeth. Levering on the upper teeth snaps them, and an inhaled tooth needs surgery. Two gentle attempts, then a different plan.
- Over-inflated cuffs scar the windpipe for life. 20–30 cmH₂O.
- Cross-infection. Boil or autoclave everything between patients (Sterilising Instruments and Dressings, Infectious Diseases).
- Flames. Nothing here should be near a flame when ether or oxygen is in use (Anaesthesia, Medical Oxygen).
What this unlocks
Airway control is the foundation of Breathing Machines and Ventilators, long operations under Anaesthesia, resuscitation (Emergencies) and intensive care (Running a Hospital, Pulse Oximeters and Patient Monitors). It also made chest surgery possible: a chest cannot be opened unless the lungs are kept inflated through a tube.
How it was first done
In 1543 Andreas Vesalius kept an opened-chest animal alive by blowing into a reed tied into its windpipe, and Charles Kite of Gravesend described curved metal tubes for reviving the drowned in 1788.
In Glasgow in 1878–80 the surgeon William Macewen passed a flexible metal tube by feel through the mouth into the windpipe of an awake patient before a throat operation: the first deliberate oral intubation for anaesthesia. Chevalier Jackson in Philadelphia built a practical lighted laryngoscope around 1913 and standardised the three-part tracheostomy tube. Just after the First World War, anaesthetising soldiers whose faces were being rebuilt at Sidcup, Ivan Magill and Stanley Rowbotham developed wide-bore rubber tubes, blind nasal intubation and the angled forceps, making intubation routine. Arthur Guedel and Ralph Waters added the inflatable cuff in 1928 and Guedel the oral airway in 1933. Robert Miller published the straight blade in 1941 and Robert Reynolds Macintosh at Oxford the curved blade in 1943. In the 1952 Copenhagen polio epidemic Bjørn Ibsen's tracheostomies and hand-squeezed bags roughly halved the deaths among paralysed patients, and modern intensive care began (Breathing Machines and Ventilators).
Source: content/entries/health/airway-equipment.md