Part 6 · Building
Heat Pumps and District Heating
A refrigerator run the other way round warms a house with heat pumped out of the ground, a river or the air — three or four units of heat for every unit of power. And one central plant, using the waste heat of a power station or factory, can heat a whole town through buried insulated pipes.
- Difficulty
- ●●●●●
- Time
- A small water-source heat pump is a workshop project of several months; a district heating main is a town's work over several summers
- Steps from zero
- 47 prerequisites →
This unlocks
—The full path from nothing — 47 steps before this one
- Stone Tools
- Cordage and Rope
- Fire
- Finding and Preparing Clay
- Finding and Identifying Ores
- Measurement from Scratch
- Writing and Numbers
- Basic Woodworking
- Hunting and Trapping
- Charcoal
- Pottery
- The Kiln
- Arithmetic and Fractions
- Hides and Leather
- Salt
- Lime
- Tiles and Clay Pipes
- Bricks
- Surveying and Levelling
- Fermentation
- Lye and Potash
- The Wheel and Axle
- Glass
- Firebrick and Refractories
- Bellows
- The Lathe
- Gears
- Iron (the Bloomery)
- Copper Smelting
- Lead
- Laboratory Glassware
- The Waterwheel
- Blacksmithing
- The Blast Furnace and Cast Iron
- Pipes, Plumbing and Aqueducts
- The Battery
- Steel
- Sheet Metal and Rolling
- Chimneys, Stoves and Heating
- The Steam Engine
- Electrolysis
- Hydrogen, Oxygen and Gases
- Machine Tools
- Boilers and Pressure Vessels
- Hot Water and Central Heating
- Ammonia
- Ice and Refrigeration
- Heat Pumps and District Heating
Do them roughly in this order. See it on the tech tree →
Why it matters
Burning fuel to heat a house is wasteful in two ways. A stove sends a third of its heat up the chimney (Chimneys, Stoves and Heating). And burning anything to make low-grade warmth, water at 40 °C, throws away the high temperature of a flame that could have run an engine.
A heat pump fixes the second waste. It is a refrigerating machine (Ice and Refrigeration) whose cold side sits in the ground, a river or the outside air, and whose hot side heats the house. It does not make heat; it moves heat that is already there, from a cold place to a warm one. Because moving heat takes much less work than making it, a good heat pump delivers 3–5 kWh of heat for every 1 kWh of power it uses. With electricity from Water Turbines and Hydroelectric Powers or Wind Turbiness, that heats houses with no fuel and no smoke.
District heating fixes the first waste, and much more. Instead of a fire in every house, one large plant makes hot water and pumps it through insulated pipes under the streets. Large plants burn poor fuels cleanly, and the waste heat of a power station, a foundry, a brewery or a sewage works, which would otherwise warm a river, heats the town (The Steam Turbine, Power Lines and Distribution). A heat pump and a district main together can take the heat out of a river or a sewer and heat thousands of homes with it.
How it works
Pumping heat uphill
Heat flows by itself only from hot to cold, just as water flows only downhill. A Pumps lifts water uphill with work. A heat pump lifts heat "uphill", from cold to hot, with work. The machine is the vapour-compression cycle of Ice and Refrigeration:
- Evaporator (cold side). Liquid refrigerant at low pressure boils at below the temperature of the source (ground, water or air), so it soaks heat out of it.
- Compressor. Squeezes the vapour, raising its pressure and temperature.
- Condenser (hot side). At high pressure the vapour condenses at 35–55 °C, giving up the heat from the source plus the compressor's work to the house's heating water.
- Expansion valve. The liquid returns through a throttle to the low-pressure side.
A refrigerator uses the cold side and throws the warm side away. A heat pump uses the warm side and draws heat from the cold side.
The coefficient of performance
The coefficient of performance (COP) is the heat delivered divided by the work put in. A COP of 4 means 4 kWh of heat for 1 kWh of power, of which 3 kWh came free from the ground.
The best possible COP (the Carnot limit) depends only on the two temperatures, in kelvin (°C + 273):
COP (best possible) = T(hot) ÷ (T(hot) − T(cold))
Real machines reach about 40–55% of this limit. Some examples:
| Source → delivery | Temperature lift | Best possible COP | Real COP |
|---|---|---|---|
| Ground at 5 °C → floor heating at 35 °C | 30 °C | 10.3 | 4–5 |
| Well water at 10 °C → radiators at 45 °C | 35 °C | 9.1 | 3.5–4.5 |
| Air at 0 °C → radiators at 55 °C | 55 °C | 6.0 | 2.5–3 |
| Air at −15 °C → hot water at 60 °C | 75 °C | 4.4 | 1.5–2 |
(The refrigerant actually works a few degrees colder than the source and hotter than the delivery, because heat needs a temperature difference to flow through a pipe wall. The table includes this in the real figures.)
The lesson: keep the lift small. Every degree you lower the delivery temperature or raise the source temperature improves the COP by about 2–3%. Heat the house with big radiators or pipes in the floor running at 30–45 °C, not small radiators at 70 °C. Draw from water or deep ground rather than winter air. Insulate the house first (Insulation and Keeping Buildings Warm or Cool), so a lower temperature is enough.
Heat sources
| Source | Temperature in winter | How much heat | Notes |
|---|---|---|---|
| Outside air | −20 to +10 °C | Unlimited | Cheapest to build. Worst COP just when heat is most needed. Coils frost up. |
| Shallow ground (horizontal loop, 1–2 m deep) | 0–8 °C | About 10–30 W per m² of ground, or 15–30 W per metre of pipe | Needs a big plot: roughly 1.5–3 times the heated floor area. |
| Borehole (vertical loop, 50–150 m deep) | 8–12 °C, steady | About 30–60 W per metre of borehole | Small footprint; needs a drilling rig (Drills and Boring, Wells and Cisterns). |
| Ground water from a well | 8–12 °C all year | About 1 kW per 3–4 litres a minute, cooled by 4–5 °C | Excellent COP. Needs a second well or soakaway to return the water. |
| River, lake, sea | 2–10 °C | Large | Ideal for big plants and towns. Intake screens must be kept clear. |
| Sewage, mine water, factory cooling water | 10–30 °C | Depends on flow | Warm all year: the best sources of all. |
How much water? Heat carried by water = flow (kg/s) × 4.18 × temperature change (°C), in kW. To take 6 kW out of well water cooled by 4 °C, you need 6 ÷ (4.18 × 4) = 0.36 kg/s, about 22 litres a minute.
Antifreeze. A closed loop in the ground or a pipe through a lake carries brine, because it runs below 0 °C. Use salt or calcium chloride in water, about 20% by weight, which freezes below −15 °C (Salt). Alternatively use a mixture of water with 25% alcohol (Distillation). Salt brines corrode iron, so add a little lime to keep them alkaline, and never let air into the loop.
What you need
| Part | How to make it |
|---|---|
| Compressor | A piston compressor with steel valves and a tight gland, as in Ice and Refrigeration and Bellows to Air Compressors. Driven by an The Electric Motor, or a water turbine. About 1 kW of drive for 3–5 kW of heat. |
| Refrigerant | Ammonia (Ammonia) is the best and is used in big heat pumps today. Use only steel and iron with it: it attacks copper and brass. Propane or isobutane (Natural Gas and Helium, Petroleum and Refining) suit small sealed machines with copper pipe, sited outdoors. Carbon dioxide suits hot water but needs pressures near 100 bar. |
| Evaporator and condenser | Heat exchangers: coils of pipe in a tank, or tube-in-tube (below). |
| Expansion valve | A fine needle valve, set by hand, or a thermostatic valve that opens as the suction pipe warms (Thermostats and Automatic Control). |
| Ground loop | Steel pipe, tarred and wrapped against rust (Corrosion and Its Prevention), or copper pipe in sand (not for ammonia). Plastic pipe where it exists (Early Plastics). |
| Circulating pumps | Small centrifugal pumps for the brine and the house water (Centrifugal Pumps and Fans). |
| Gauges and controls | Pressure gauges on both sides (Pressure and Vacuum Gauges), thermometers, a thermostat, and high-pressure and low-pressure cut-out switches. |
Working pressures. With ammonia evaporating at −5 °C and condensing at 50 °C, the low side runs at about 3.5 bar and the high side at about 20 bar. With propane the figures are about 4 and 17 bar. Make and test every part of the high side for at least twice that, with water, before charging (Boilers and Pressure Vessels, Pressure Vessels and Valves).
Building a water-source heat pump
This is the most achievable heat pump: well or river water is warm in winter, and nothing frosts up.
The heat exchanger
A heat exchanger passes heat from one fluid to another through a metal wall without mixing them (Heat Exchangers). The simplest, and one you will need again and again, is the tube-in-tube (double-pipe) exchanger:
- Run a smaller pipe (say 15–20 mm) inside a larger one (32–40 mm), with tees and packing glands at each end so the two fluids enter and leave separately.
- Pass the refrigerant one way through the inner pipe and the water the opposite way through the space between (counterflow). Counterflow lets the water leave almost as hot as the incoming refrigerant.
- Coil it into a spiral to save space, or lay it in hairpin lengths.
- Size it roughly: clean steel tube passes about 0.3–0.5 kW per m² of tube wall for each 1 °C of temperature difference between the water and the boiling or condensing refrigerant. For a 6 kW heat pump with about 5 °C difference across each exchanger, allow 2–4 m² of wall in each one. That is 30–60 m of 20 mm tube, so a coil in a tank is often easier to build.
Coil-in-tank versions are simpler still. A steel coil carrying refrigerant sits in a barrel of brine (the evaporator), or in the hot water cylinder itself (the condenser), as in Hot Water and Central Heating.
Assembly
- Mount the compressor and its motor on a heavy base, with the evaporator and condenser beside it and the pipe runs short.
- Pipe it up: compressor outlet → condenser → a small liquid receiver (a steel bottle) → sight glass → expansion valve → evaporator → a suction trap (a vertical bottle that catches any liquid) → compressor inlet.
- Water circuits: well pump → evaporator jacket → return well. Heating pump → condenser jacket → floor pipes or radiators → back.
- Pressure test the refrigerant side with water at twice working pressure. Then drain it, dry it with warm air, and evacuate it with a The Vacuum Pump for several hours to pull out air and water.
- Charge the refrigerant slowly into the low side, with the compressor running, until the sight glass shows clear liquid with no bubbles.
- Set the expansion valve. Open it until the evaporator is cold along its whole length but the suction pipe at the compressor is only 5–8 °C warmer than the evaporator (this margin is called superheat). With too much opening, liquid reaches the compressor, the suction pipe frosts heavily and the compressor knocks. Liquid in a compressor breaks valves. With too little opening, the evaporator is cold only at its start and output falls.
- Set the cut-outs: high pressure stops the motor if the condenser water fails, and low pressure stops it if the evaporator freezes.
Measuring COP
Measure the heating water flow with a bucket and a watch, and the temperatures in and out of the condenser. Heat (kW) = flow (kg/s) × 4.18 × temperature rise. Divide by the electrical power, measured with a meter (Measuring Electricity). A home-made machine with a COP of 3 is a success.
The heat pump with an air source
An air-source heat pump uses a finned coil, with fins 4–6 mm apart, and a fan that blows 0.5–1 m³ of air per second through it for each 3 kW. In damp air below about 5 °C the coil frosts. It must be defrosted every 30–90 minutes, by a reversing valve that sends hot gas back through the coil for a few minutes, or by switching on a heater. Expect the COP to fall to 2 or less in hard frost. The air source is cheapest to build, but the water or ground source gives more heat for the same power.
Emitters
Heat pumps want low-temperature emitters:
- Underfloor pipes: 15–20 mm pipe at 15–20 cm spacing in a screed over insulation, running at 30–40 °C (Laying Tiles and Mosaics goes well on top).
- Radiators two to three times the size of those for a boiler at 70–80 °C, or many lengths of finned pipe.
Store hot water in a well-insulated cylinder at 50–55 °C. Once a week, raise it to 60 °C or above, with an electric heater, to kill Legionella bacteria (see Dangers).
District heating
The central plant
The plant heats water and pumps it round a closed loop. Its heat can come from:
- Combined heat and power. A steam power plant (The Steam Turbine) turns only 25–40% of its fuel into electricity; the rest goes out of the condenser as warm water, usually thrown away in a river or a cooling tower. Run the turbine so its exhaust steam condenses at 80–100 °C instead of 30 °C. You lose a little electricity, but the condenser now heats the town. The total use of the fuel rises to 75–90%.
- Waste heat from foundries (The Blast Furnace and Cast Iron), glassworks, breweries (Beer, Wine and Cider), kilns (The Kiln), creameries, biogas engines (Biogas and Wood Gas, Gas Engines and Producer Gas) and refrigeration plants.
- Large heat pumps on a river, lake, sewage outfall or mine.
- Boilers burning wood chips, sawmill waste (Sawmills and Lumber), straw or refuse, for the coldest days and as a reserve.
- Hot springs, where they exist (Geothermal, Tidal and Wave Power).
A large insulated heat store (a tank or covered pit of water) lets the plant run steadily while demand rises and falls through the day (Storing Energy).
Temperatures and sizes
| System | Flow / return | Notes |
|---|---|---|
| Steam (oldest) | 120–200 °C steam | Losses high, condensate traps fail; avoid in new systems. |
| High-temperature hot water | 100–130 °C / 50–70 °C | Pressurised so it does not boil. Carries much heat in small pipes. |
| Low-temperature hot water | 60–80 °C / 30–45 °C | Lower losses; suits heat pumps and waste heat. Best for new schemes. |
Sizing a main. Heat carried = water flow × 4.18 × (flow temperature − return temperature). Keep water speed at 1–3 m/s. A 100 mm pipe at 2 m/s carries about 15.7 litres a second. With 40 °C between flow and return, that is about 2,600 kW: enough for some 300–500 well-insulated houses, because they never all need full heat at once. The cooler the return, the more heat each pipe carries. So each house must be made to send its water back really cool.
Laying the district heating main
A district heating main is a pair of insulated pipes, flow and return, buried under the street.
- Pipe. Use welded steel pipe (Metal Pipes and Tubes, Welding), with every joint tested with water at 1.5 times working pressure.
- Insulation. Wrap each pipe in 5–10 cm of mineral wool, slag wool, cork or similar (Insulation and Keeping Buildings Warm or Cool, Glass Fibre and Glass Wool). Cover it with a waterproof layer of tarred felt or sheet metal. Wet insulation does not insulate.
- Duct. Lay the pair on rollers or sliding supports in a concrete or brick duct with a lid. Give it a drain at its low points, so ground water never reaches the pipes. (The modern alternative is pre-insulated pipe: steel pipe foamed inside a plastic jacket and buried straight in sand.)
- Expansion. Steel grows 1.2 mm per metre for every 100 °C. A 100 m run heated from 10 °C to 90 °C grows by about 10 cm. Fix the pipe at anchors, and between them take up the growth with U-shaped expansion loops or sliding expansion joints, every 50–100 m. Guides keep the pipe in line.
- Vents and drains. Lay the main with a slight fall (about 1 in 300), with air vents at every high point and drain valves at every low point.
- Pumps and pressure. Centrifugal pumps (Centrifugal Pumps and Fans) at the plant push the water round. A pressurised expansion vessel keeps the whole network above boiling pressure, and takes up the water's own expansion (Hot Water and Central Heating).
- Water treatment. Fill with soft, de-aerated water (Water Treatment for a Town), and keep it slightly alkaline. Oxygen and hardness destroy a steel network from inside.
A well-built network loses 5–15% of its heat a year to the ground.
The substation and heat meter
At each building, a substation takes heat from the main:
- A heat exchanger (coil, tube-in-tube or plate type) passes heat from the network water to the building's own heating water and hot-water cylinder. The waters never mix, so a leak in a house cannot drain the town's network.
- A control valve worked by a thermostat (Thermostats and Automatic Control) opens only as far as needed, keeping the return water cool.
- A heat meter measures the water flow (a turbine or vane meter, like a water meter) and the flow and return temperatures, and multiplies them to record kilowatt-hours. Without meters, people leave windows open and the plant runs out of heat. The simplest meter counts flow with a vane wheel geared to a counter (Clockwork, Music Boxes and Counting Machines), and the bill is worked out from the average temperature difference read each week.
How to tell it worked
- Heat pump: the evaporator water comes out 3–5 °C colder than it went in, and the condenser water 5–10 °C warmer. The suction pipe is cool but not frosted thickly. The compressor runs quietly, without knocking. The measured COP is 3 or better on a water source.
- District heating: the return temperature at the plant stays at least 30 °C below the flow. The far end of the network gets water within a few degrees of the flow temperature. Snow on the street above a main does not melt in a stripe; if it does, the insulation is wet or missing.
Note Troubleshooting. High-pressure cut-out trips → condenser water flow too low or radiators turned off. Check the heating pump and open more circuits. Low-pressure cut-out trips, evaporator iced → source water flow too low, ground loop too short, or refrigerant short (bubbles in the sight glass). Increase flow, add loop, or find the leak. Compressor knocks, suction pipe heavily frosted → expansion valve too wide open; liquid is reaching the compressor. Close it slowly. Poor COP → delivery temperature too high. Lower it and enlarge the emitters. Ground loop colder each winter → the loop is too short for the heat taken. Lengthen it, or put heat back in summer (cooling the house, or a solar collector, Solar Heat). District return water too hot → substations bypassing, control valves stuck open. Find them by reading the meters. Far end of the network cold → pipe too small or air locked in it. Vent the high points, raise pump pressure, or add a loop to feed it from both ends.
Dangers
Danger Refrigerants. Ammonia is poisonous: a leak in a closed room can kill, and liquid ammonia burns the eyes and skin. Its sharp smell warns at harmless levels, so leave at once when you smell it strongly. Find small ammonia leaks with a burning sulfur stick (it makes white fumes). Propane and isobutane are explosive in air and heavier than air, so they collect in cellars. Keep such machines outdoors, with small charges and no sparks nearby. Find leaks with soapy water, never with a flame.
Danger Hot water under pressure. Water above 100 °C in a pressurised main flashes to steam the instant a pipe bursts, scalding anyone nearby and blowing open the trench. Open district heating chambers and ducts only when the section is isolated and cooled. Always have two ways out of a pipe chamber.
- Pressure vessels. The high side of a heat pump is a pressure vessel. Test it hydraulically at twice working pressure, and never with air (Pressure Vessels and Valves).
- Electricity and water meet in every heat pump. Earth every metal frame and use an earth-leakage breaker (Wiring and Electrical Safety, Motor Starters, Contactors and Protection).
- Legionella. These bacteria breed in water at 20–45 °C and cause a deadly pneumonia when breathed in as spray from showers. Store hot water at 60 °C, or heat it to 60 °C at least weekly, and do not leave dead legs of lukewarm pipe.
- Trenches for loops and mains collapse. Shore any trench deeper than 1.2 m (Tunnels and Rock Drilling).
- Never make chlorofluorocarbons as refrigerants: they destroy the ozone layer (Ice and Refrigeration).
What this unlocks
Heat pumps let a place with plenty of electricity from water and wind heat itself without burning anything, and the same machine cools buildings in summer. Run at higher temperatures, they recover heat in industry: drying timber in Sawmills and Lumber, evaporating brine for Salt, concentrating milk and sugar juice (Sugar), and distilling (Distillation). District heating ties a town's power, industry and waste into one system, and is the natural partner of town planning, Sewers and Wastewater and the Power Lines and Distribution.
How it was first done
William Thomson (Lord Kelvin) described a "heat multiplier" in 1852. It was a machine that would warm a building with heat pumped from the outside air, using less work than a fire would need. In 1855–1857 the Austrian engineer Peter von Rittinger built the first working heat pump. It recompressed the steam rising from boiling brine in a salt works, so that it could heat the brine again. Heat pumps for buildings came in the 1930s. In 1938 the city hall of Zürich, Switzerland, was heated by a heat pump that drew heat from the river Limmat. In the 1940s the American inventor Robert C. Webber built early ground-source heat pumps. In 1951 London's Royal Festival Hall was heated by a heat pump on the Thames.
District heating is older. Hot springs heated houses through wooden pipes at Chaudes-Aigues, in France, from the 1300s. In 1877 Birdsill Holly piped steam to buildings in Lockport, New York. The New York Steam Company began supplying Manhattan in 1882, and still does today. Hot-water networks fed by power stations grew in Germany, Denmark and the Soviet Union from the 1920s. Reykjavík, in Iceland, began heating its houses with geothermal water in 1930. Today Denmark, Sweden and Finland heat most of their town homes this way.
Source: content/entries/building/heat-pumps.md