◆ Rebuild

Part 14 · Electronics and Computing

Electronic Test Equipment

You cannot build or mend electronics you cannot measure. How to make the multimeter that reads volts, amps and ohms on one dial; the signal generators that supply test tones and radio signals of known frequency; the oscilloscope that draws a signal's shape; testers for valves and transistors; bridges that measure resistance, capacitance and inductance; and how to keep all of them honest by calibration.

Difficulty
●●●●●
Time
A week for a multimeter; two to three weeks for a signal generator or bridge; one to two months for an oscilloscope
Steps from zero
32 prerequisites →

You need first

Measuring ElectricityAmplifiers and Oscillators

This unlocks

—
The full path from nothing — 32 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. Charcoal
  9. Pottery
  10. The Kiln
  11. Hides and Leather
  12. Lime
  13. Mercury
  14. Fermentation
  15. Lye and Potash
  16. The Wheel and Axle
  17. Glass
  18. Bellows
  19. The Lathe
  20. Copper Smelting
  21. Iron (the Bloomery)
  22. Laboratory Glassware
  23. Pumps
  24. Blacksmithing
  25. The Battery
  26. The Vacuum Pump
  27. Copper Wire
  28. The Light Bulb
  29. The Electromagnet
  30. The Vacuum Tube
  31. Measuring Electricity
  32. Amplifiers and Oscillators
  33. Electronic Test Equipment

Do them roughly in this order. See it on the tech tree →

Why it matters

A radio that does not work tells you nothing about why. With a meter you can find the stage where the voltage is wrong; with a signal generator you can feed a known signal in and follow it through; with an oscilloscope you can see whether a wave is clean, clipped or buried in hum. Without these instruments, every fault is a guess and every design is trial and error. With them, one technician can build, tune and repair the Radio, The Automatic Telephone Exchange, Cathode Rays and Television and The Computer equipment of a whole region.

Test equipment is also how a society keeps its electrical units the same everywhere. A volt in one workshop must be a volt in the next, or parts made in one place will not work in another (Precision and Interchangeable Parts, Measurement from Scratch).

This chapter builds on the meters, shunts, resistance boxes and Wheatstone bridge of Measuring Electricity, the CRT of Cathode Rays and Television, and the tubes and oscillators of Amplifiers and Oscillators. It does not repeat them.

What you need

Item Notes
Moving-coil meter movement, as sensitive as you can make 1 mA full scale at least; 50 µA is far better (Measuring Electricity)
Resistance wire Constantan or German silver, for shunts and multipliers (Nickel and Cobalt)
Precision resistors Wound and adjusted against your standards (Resistors, Capacitors and Coils)
Rotary switches Brass wipers on a slate, ebonite or waxed hardwood disc, below
Rectifiers Copper-oxide or germanium junctions for AC ranges (Semiconductors and the Transistor)
Tubes or transistors For amplifiers, oscillators and time bases (The Vacuum Tube, Semiconductors and the Transistor)
A cathode-ray tube Cathode Rays and Television
Variable capacitors, coils Resistors, Capacitors and Coils
Sheet steel or copper boxes Screened cases (Sheet Metal and Rolling, Building Circuits: Boards, Connectors and Cables)
Headphones The most sensitive AC detector you have (The Telephone)

Where to find it

Every raw material here comes through other chapters. Slate and mica insulate switches and terminals (look for flat-splitting dark rock and glittering sheets in pegmatite veins). Seasoned hardwood boiled in beeswax, or soaked in lac varnish, makes cases and switch discs that do not take up damp.

The rotary switch

Every instrument here needs a good range switch. Its contact resistance must be tiny and must not change.

  1. Cut a disc of slate, ebonite or waxed hardwood 6–8 cm across. Set 12 brass studs round it on a circle, each 6 mm across with flat polished heads standing 1 mm proud.
  2. A central spindle carries a wiper of springy phosphor-bronze or hard brass, bent so it presses each stud firmly, with a click spring and a notched wheel so it stops squarely on each.
  3. Wipers that make two-point contact (forked, or two wipers side by side) are much more reliable.
  4. Keep the studs clean and lightly greased with petroleum jelly.

The multimeter

1 DC volts2 DC current3 AC volts4 Ohms +COMSeries resistorvolts × ohms-per-volt− meter resistance +COMShuntcarries mostof the current ~COM+−Bridgerectifiermark the scale1.11 × higher CellZero adjustset full scale withleads touchingunknown across the leads
Fig. 1 The four jobs of a multimeter. The range switch connects the one moving-coil meter in one of four ways: behind a series resistor to read volts, beside a shunt to read current, behind a bridge rectifier to read AC volts, or in series with a cell and a zero-adjust resistor to read ohms.

A multimeter puts an ammeter, voltmeter and ohmmeter into one box with one meter and one switch.

Choosing the meter

The more sensitive the meter, the less it disturbs what it measures. A voltmeter's quality is written as ohms per volt: 1 ÷ full-scale current.

Meter Ohms per volt On the 250 V range it draws
10 mA 100 10 mA: useless on tube circuits
1 mA 1,000 1 mA: fine for power circuits; lowers readings on tube plates
50 µA 20,000 0.05 mA: good for nearly everything

Use finer wire, more turns, a stronger magnet, glass-bead pivots and softer hairsprings (Measuring Electricity). A 1 mA, 100 Ω movement is a good first target.

DC volts

For each range, a series resistor = range in volts × ohms per volt − meter resistance. With a 1 mA, 100 Ω meter:

Range Total resistance Series resistor
2.5 V 2,500 Ω 2,400 Ω
10 V 10,000 Ω 9,900 Ω
50 V 50,000 Ω 49,900 Ω
250 V 250,000 Ω 249,900 Ω

Wind them in constantan or build them of carbon sections (Resistors, Capacitors and Coils), each adjusted to 1% against your resistance box. Chain them so each range uses the ones below it plus its own.

DC current

Shunts across the meter (Measuring Electricity). So that switch contact resistance never sits in a shunt, use the universal (Ayrton) shunt: one tapped resistance permanently across the meter, the switch choosing where current enters. A 1 mA meter of 100 Ω with ranges of 10 mA, 100 mA and 1 A needs a total shunt of about 11.1 Ω, with the 100 mA input tapped 1.11 Ω and the 1 A input 0.111 Ω from the common end. Fuse the current ranges.

AC volts

Put a bridge of four small rectifiers (Semiconductors and the Transistor, Rectifiers: Turning AC into DC) before the meter. It reads the average of the rectified wave, 0.9 times the RMS value for a sine wave, so mark the scale 1.11 times higher. Rectifiers are not straight on low ranges, so calibrate each AC range point by point against a moving-iron meter. Readings hold only for sine waves at mains and audio frequencies.

Ohms

Put a 1.5 V cell, a fixed resistor and a zero-adjust variable resistor in series with the meter. Short the leads and set full scale: that is 0 Ω. An unknown resistance lowers the current; half scale is where it equals the circuit's own resistance, 1,500 Ω for a 1 mA meter on 1.5 V. Mark the backwards scale with known resistors. A 15 V battery gives a range ten times higher.

Good multimeter: reads a Daniell cell as 1.10 V; agrees within 2% on adjacent ranges; returns to exact zero.

The valve voltmeter

For grid circuits, where even 20,000 Ω per volt draws too much, put an amplifier before the meter: two triodes in a balanced pair with the meter between their cathodes. The input goes to one grid through a divider of 10–11 MΩ, the same on every range; the balance cancels drift as the tubes warm. A diode at the probe tip reads radio-frequency voltages.

Signal generators

Audio oscillator

  • Simplest: a buzzer (Electric Bells, Buzzers and Alarms), or a two-tube multivibrator (Electronic Counters). Rich in harmonics, fine for bridges and rough tests.
  • Pure tones: the Wien bridge. An amplifier of two stages is fed back to its own input through a network of a resistor and capacitor in series, then a resistor and capacitor in parallel. Only one frequency gets through this network in step with the output: f = 1 ÷ (2 × 3.14 × R × C). A second, negative feedback path through a small filament lamp (a 6 V, 50 mA torch bulb works) holds the output steady and the wave clean.
  • Tuning: use a two-gang variable capacitor (two sections on one shaft, Resistors, Capacitors and Coils) of about 500 pF for C, and switch R in decades. With 500 pF to 50 pF, R = 1.6 MΩ covers about 200–2,000 Hz; switch to 160 kΩ for 2–20 kHz and 16 MΩ for 20–200 Hz.
  • Calibrate the dial against tuning forks (Sound, Pitch and Acoustics) by beats, against the mains (50 or 60 Hz) using Lissajous figures on an oscilloscope (below), or against a frequency counter (Electronic Counters).

Radio-frequency generator

A tube oscillator (Amplifiers and Oscillators) tuned by a coil and variable capacitor, with plug-in coils for each band, built in a closed copper or steel box so that no signal leaks out except through the output socket.

  1. Mount the tuning capacitor on a slow-motion drive of 10 : 1 or more with a large dial.
  2. Modulate it with the audio oscillator at 400 Hz, about 30%, so that a receiver tuned to it gives an audible tone.
  3. Output attenuator: a chain of resistors switched in steps of 10 : 1 (a ladder of, for example, 75 Ω and 680 Ω sections), in its own screened compartment, so you can feed a receiver from about 0.1 V down to a few millionths of a volt.
  4. Calibrate the dial. The best way: a 100 kHz crystal oscillator (Quartz Crystals and Frequency Control) gives "markers" every 100 kHz all the way up; tune a receiver to the generator and to each marker in turn and listen for zero beat (the whistle falling to silence). Broadcast and time-signal stations of known frequency serve as well.

Absorption wavemeter

The simplest frequency check: a coil and calibrated variable capacitor with a small lamp, or a crystal detector and meter, across them, and no power source. Hold it near an oscillator's coil and turn the dial: at resonance the lamp glows or the meter peaks. Calibrated once against crystal markers, it is good to 1–2% and nearly indestructible.

The oscilloscope

The cathode-ray tube itself, its high-voltage supply and a simple time base are built in Cathode Rays and Television. To make it a measuring instrument, add amplifiers, a triggered time base and calibration.

Input Attenuator×1 ×10 ×100 Y amplifiergain about 300 Triggerlevel knob Time basesweep speed X amplifierpush-pull Calibrator1 V square wave to Y plates to X plates Cathode-ray tube gun screen sawtooth: slow sweep, fast return 1 cm grid on the face
Fig. 2 The oscilloscope as an instrument. The input signal goes through a stepped attenuator and the vertical amplifier to the Y plates. A trigger circuit picks a point on the same signal and starts the time base, whose sawtooth sweeps the spot across the screen through the horizontal amplifier. The calibrator gives a square wave of known height to check the scale. The screen carries a grid of centimetre squares.
  1. Vertical (Y) amplifier. The deflection plates need about 30 V per centimetre (Cathode Rays and Television). To show signals of 0.1 V per centimetre, you need a gain of about 300: two or three resistance-coupled tube stages, the last as a push-pull pair driving both plates in opposite directions, which keeps the spot in focus. Small coupling capacitors and low plate resistors (5–10 kΩ) let it pass signals up to a few hundred kilohertz.
  2. Input attenuator. A switch of resistor dividers giving ×1, ×10, ×100 with a 1 MΩ input. Fit a small trimmer capacitor across each upper resistor and adjust it so a square wave stays square on every range.
  3. Time base. A capacitor charged through a high resistance gives the sweep; a gas triode or a pair of tubes discharges it (Cathode Rays and Television, Electronic Counters). Switch capacitors and resistors to give sweep times from about 10 ms to 10 µs per centimetre.
  4. Trigger. A repeating wave looks still only if each sweep starts at the same point on it. Feed some of the vertical signal to a Schmitt trigger (Electronic Counters) that fires when the signal crosses a level you set with a knob, and let that pulse start each sweep. A trace that stands still at any sweep speed is the mark of a good scope.
  5. Graticule. Scratch or paint a grid of 1 cm squares on a glass plate in front of the screen, lit from the edge.
  6. Calibrator. A switching tube or relay clipping the mains to a square wave of 1 V peak-to-peak, set against your multimeter, on a socket on the front panel.

Using it

  • Voltage: count centimetres of height × volts per centimetre on the attenuator setting.
  • Time: count centimetres of width × time per centimetre. Frequency = 1 ÷ time of one cycle.
  • Lissajous figures: switch off the time base, put a known frequency on the X plates and the unknown on Y. If they are equal, you see an ellipse or a line; if the unknown is twice, a figure of eight; in general, the number of loops touching the top edge divided by the number touching a side edge gives the unknown frequency divided by the known. With the mains as the known frequency, this calibrates an audio oscillator without any other instrument.
  • A ×10 probe: a 9 MΩ resistor with a small trimmer capacitor across it, in the tip of the probe, makes the scope draw almost nothing from the circuit under test.

Valve and transistor testers

The valve tester

  1. Sockets for every base you use, all wired in parallel to a set of selector switches so any pin can be connected to filament, cathode, grid, anode or screen.
  2. Filament transformer with taps at the common voltages (1.4, 2, 2.5, 4, 5, 6.3 and 12.6 V for the common modern types; your own tubes set your own list).
  3. Shorts test first: with the filament hot, connect a small neon lamp with a 100 V supply between each pair of electrodes in turn. A glow means two electrodes are touching. Tap the tube gently; a flicker means an intermittent short.
  4. Emission test: join grid, screen and anode together, apply about 30 V through the meter, and read the current. Record the reading for a new tube of each type and paint it on a card in the lid. A tube giving less than about 60% of a new one's figure is worn out.
  5. Mutual conductance (better): set normal anode voltage and grid bias, read anode current; change the grid voltage by 1 V and read again. The change in milliamps per volt is the tube's mutual conductance (mA/V). Compare with a good tube.
  6. Gas test: put 1 MΩ in the grid lead. A gassy tube draws grid current that moves the anode current when you short the resistor out; a good tube shows no change.

The transistor tester

  1. Diode test: each junction (base–emitter, base–collector) conducts one way only, as in Semiconductors and the Transistor.
  2. Leakage: with the base unconnected, 4.5 V across collector and emitter through a 1 mA meter. A small germanium transistor should pass less than about 0.1–0.5 mA; a silicon one, almost nothing. More, and it is useless.
  3. Gain: feed the base a known small current — 4.5 V through 390 kΩ gives about 10 µA — and read the collector current. Current gain = collector current ÷ base current. 1 mA of collector current for 10 µA of base current means a gain of 100.

Bridges

The principle again

The Wheatstone bridge of Measuring Electricity measures resistance by balancing it against a standard until a galvanometer shows nothing. Feed the same bridge with an audio tone instead of a battery, and use headphones instead of a galvanometer, and it measures capacitance and inductance too. The balance is a silence in the phones, which you can hear far more precisely than you can read a needle.

1,000 Hz tone ab Csstandard Cxunknown loss balance Headphonessilence = balance Sliderbrass knife-edge 1 m bare wire on a scale At silence: Cx = Cs × a ÷ b (for resistors the same bridge gives X = R × b ÷ a)
Fig. 3 A slide-wire bridge for capacitance. A 1,000 Hz tone feeds the bare wire and, in parallel, the standard capacitor and the unknown in series. The headphones connect the slider to the junction of the two capacitors. Move the slider to where the tone fades to silence. A small variable resistor in series with the standard balances out the losses of a leaky capacitor.

Capacitance

  1. Use the slide-wire bridge, with a standard capacitor Cs in the left arm and the unknown Cx in the right arm.
  2. Feed it from the audio oscillator or a buzzer at about 1,000 Hz; connect headphones from the slider to the junction of the two capacitors.
  3. Slide to the point of silence. Read lengths a (on the side of the standard) and b.
  4. Cx = Cs × a ÷ b. Note that this is the opposite way round from resistance (X = R × b ÷ a), because a larger capacitor lets more AC through, not less.
  5. If the silence is never complete, the unknown has losses (paper capacitors and electrolytics always do). Put a small variable resistor in series with the standard and adjust it and the slider in turn until silence is complete. The resistor setting tells you how lossy the capacitor is.

Inductance

Use the same bridge with a standard coil Ls in place of Cs: Lx = Ls × b ÷ a, the same way round as for resistance. Iron-cored chokes change with current, so measure them at the current they will carry. Or use a Maxwell bridge, which compares a coil against a standard capacitor and resistors, so you need no standard coil at all.

The standard capacitor

You can make a capacitor whose value is known from a ruler alone. Two flat plates, area A in cm², a gap d in cm with only air between:

C (in pF) = 0.0885 × A ÷ d

Two brass or aluminium plates 20 × 20 cm, held exactly 1 mm apart by three small glass or quartz spacers at the edges, give 0.0885 × 400 ÷ 0.1 = 354 pF (a little more, from the edges). Use it to calibrate a set of mica capacitors (Resistors, Capacitors and Coils), and those to check everything else.

Measuring bridge for the bench

Combine it all in one box: a calibrated ratio arm with a large dial, a switch for R, C or L, standards of 100 Ω, 10 kΩ, 1,000 pF, 0.1 µF and 10 mH, and a built-in buzzer. This universal bridge is the workhorse of a component workshop.

Calibration

An instrument is only as good as the last time it was checked against something better.

Quantity Your reference How
Voltage Daniell cell (1.10 V); better, a Weston cadmium cell (1.0186 V at 20 °C, very steady) Potentiometer (Measuring Electricity)
Current Copper coulometer Measuring Electricity
Resistance Wound standard coils Bridge
Capacitance Air-plate standard capacitor Calculated from size
Frequency Crystal standard, broadcast time signals, the grid frequency averaged over a day Zero beat, Lissajous figures, frequency counter (Quartz Crystals and Frequency Control)
Time Pendulum clock, the stars (The Mechanical Clock, Standard Time and Timetables) Counting cycles
  1. Keep a master set of standards in one place, cool and dry, used only to check other instruments.
  2. Check working instruments against the master set every few months and after any knock or overload. Check each range at two or three points.
  3. Label each instrument with the date of its check and its error, and keep a book.
  4. Compare master sets between towns now and then by carrying a standard cell and a standard resistor from one to the other. This is how every country's units stay equal to every other's.

How to tell it worked

  • Multimeter: every DC range reads a standard cell or potentiometer voltage within 2%; AC reads a known transformer winding within 5%.
  • Signal generator: its dial agrees with crystal markers or a wavemeter within 2%; a receiver hears nothing from it with the output turned to zero.
  • Oscilloscope: the calibrator square wave is square, flat-topped and of the right height on every range; a steady sine wave stands still on the screen.
  • Valve tester: a new tube and a known old tube give clearly different readings, the same each time.
  • Bridge: the same capacitor measured against two different standards agrees within 1%.

Note Troubleshooting. Meter reads differently on adjacent ranges → a range resistor out of value, or switch contact resistance. Clean the switch, recheck the resistors. Ohms range will not zero → cell run down. Oscillator output varies across the dial → the lamp is too big or too small; try other bulbs. Distorted → too much gain, lamp not warming. Scope trace drifts sideways → no trigger, or trigger level outside the signal. Spot blurs as it moves → plates driven from one side only; use push-pull. Bridge never goes silent → losses in the unknown; add the series resistor. Silence is broad, not sharp → tone too weak or wire too short; raise the drive or use a longer wire. Generator heard with output off → close every seam of the box; filter the power leads.

Dangers

Danger Measuring live circuits. Test leads touch the full voltage of whatever you measure: 250 V or more on tube plates, and thousands of volts in a CRT supply or a transmitter (Cathode Rays and Television, Radio). Use leads with insulated probes and finger guards, keep one hand in your pocket when probing anything above 50 V, and switch off and discharge capacitors before touching any part with your hands.

  • Wrong range. A multimeter left on a current or ohms range and touched across a supply is a short circuit. The meter burns, the leads can flash and spray molten copper. Always start on the highest range and leave the switch on a high voltage range when you put it away.
  • Earthed oscilloscopes. The scope's case and the outer of its input lead are earthed. Clipping that lead to a live part of mains-connected equipment makes a short circuit through the scope.
  • Mercury. Some standard cells contain mercury and cadmium, both poisons (Mercury). Keep them sealed, and never break one open in a living space.

What this unlocks

Every later chapter in electronics leans on these instruments: tuning Radio and Cathode Rays and Television, aligning Radar and Microwaves, debugging The Computer logic, and making components to known values in quantity (Resistors, Capacitors and Coils, Integrated Circuits). Regulated supplies (Power Supplies and Regulators) make every instrument here steadier. Frequency counters (Electronic Counters) and later digital meters replace the dial with a row of digits.

How it was first done

Donald Macadie, a British Post Office engineer tired of carrying separate meters, designed the AVO ("amps, volts, ohms") meter in 1923, the first widely used multimeter. William Hewlett and David Packard founded their company in 1939 on Hewlett's lamp-stabilised Wien-bridge oscillator.

Karl Ferdinand Braun built the first cathode-ray tube for showing waveforms in 1897; in 1946–47 Howard Vollum and Jack Murdock of Tektronix made the triggered, calibrated time base standard, turning the oscilloscope from a picture into a measuring tool. Bridges are older: Samuel Hunter Christie described the bridge principle in 1833 and Charles Wheatstone made it famous in 1843; James Clerk Maxwell gave the inductance bridge in 1873, and from the 1880s telephone engineers used AC bridges with buzzers and telephone receivers. Edward Weston patented his cadmium standard cell in 1893, and it served as the international volt for most of the 20th century.

Source: content/entries/electronics/test-equipment.md