◆ Rebuild

Part 8 · Chemistry

Chromatography

Put a spot of a mixture on paper, dip the edge in a solvent, and as the liquid creeps up, each substance in the spot travels at its own speed and they spread out into separate spots. That is chromatography. With a strip of paper, a glass plate coated with silica, or a tube packed with chalk, you can see what is in an ink, a leaf, a sugar syrup or a protein, and check whether a medicine is pure. Pass the vapours through a long heated tube and you have the gas chromatograph, which measures alcohols, fuels and gases to a fraction of a percent.

Difficulty
●●●●●
Time
An hour for a first paper chromatogram; a day to make TLC plates; a week of evenings for a column; months to build a working gas chromatograph
Steps from zero
17 prerequisites →

You need first

Organic Synthesis and Fine Chemicals

This unlocks

Analytical Instruments
The full path from nothing — 17 steps before this one
  1. Stone Tools
  2. Fire
  3. Finding and Preparing Clay
  4. Simple Machines
  5. Quarrying and Cutting Stone
  6. Pottery
  7. The Kiln
  8. Mining and Tunnelling
  9. Lime
  10. Fermentation
  11. Lye and Potash
  12. Glass
  13. Distillation
  14. Coal and Coke
  15. Coal Tar Chemicals
  16. Laboratory Glassware
  17. Organic Synthesis and Fine Chemicals
  18. Chromatography

Do them roughly in this order. See it on the tech tree →

Why it matters

Most chemistry ends with "Is it pure?" and "What is in it?" Melting points answer some of that (Organic Synthesis and Fine Chemicals, Identifying Substances). Chromatography answers it directly, with tiny amounts, often in an hour.

How it works

Every chromatography has two parts:

  • a stationary phase that stays put: paper, a thin layer of silica, a column of chalk or beads, or a liquid coated on grains;
  • a mobile phase that flows past it: a solvent, or in a gas chromatograph, a gas.

Each substance spends part of its time stuck to the stationary phase and part carried by the moving phase. One that sticks strongly lags behind; one that prefers the solvent runs ahead. Thousands of tiny stick-and-release steps add up, so substances that differ only slightly end up clearly apart, the same multiplication of small differences as in a mixer-settler cascade (Separating the Rare Earths).

Polarity is the main handle. Silica, alumina, chalk and paper are polar: they hold water-loving substances (sugars, acids, amino acids) and let oily ones (fats, carotene) run. A polar solvent (water, alcohol, acetic acid) moves polar substances; a non-polar one (light petrol) moves only the oily ones. Choose a solvent that moves your spots a third to two-thirds of the way.

Rf value. On paper or a plate, measure how far each spot moved from the starting line, and how far the solvent front moved. Their ratio is the Rf ("retention factor"):

Rf = distance moved by the spot ÷ distance moved by the solvent

Rf is roughly constant for one substance on one kind of paper with one solvent, but shifts with temperature, humidity and how the plate was made. Always run a known pure sample beside the unknown on the same sheet.

Tight lid Paper liningsoaked in solvent Solvent front Pencil start line2 cm from bottom Solvent0.5–1 cm deep,below the line The tank, mid-run frontstart PurereferenceYoursample ba Rf = a ÷ b = 0.6 impurity
Fig. 1 Paper and thin-layer chromatography. The sheet or plate stands in a covered jar with solvent below the starting line. As the solvent rises, each substance in a spot moves its own distance. Rf is the distance moved by a spot divided by the distance moved by the solvent front. The sample on the right shows two spots: one matches the pure reference, the other is an impurity.

What you need

Item Notes See
Filter paper, thick and pure Chromatography paper, below Paper
Glass plates or microscope slides For TLC Window Glass, The Microscope
Silica gel, fine From water glass Water Glass (Sodium Silicate)
Plaster of Paris Binder for TLC layers Gypsum and Plaster of Paris
Chalk, alumina, or icing sugar Column packings Alum and Alumina, Sugar
Jars with lids Tanks Bottles, Drinking Glasses and Glassware
Fine glass capillaries For spotting Scientific Glassblowing and Glass-to-Metal Seals
Solvents: water, alcohol, acetone, butanol, acetic acid, ethyl acetate, light petrol Ether, Acetone and Solvents, Fermentation, Vinegar and Pickling
Detecting reagents: iodine, ninhydrin, ferric chloride, silver nitrate Below Iodine, Silver Nitrate and Silver Salts

Where to find it

  • Cotton makes the purest paper: lint or clean white rags, boiled with soda and well rinsed (Cotton).
  • Chalk is soft white limestone: chalk downs and pale cliffs (Lime). It fizzes in vinegar.
  • Diatomaceous earth, also called kieselguhr, is a pale, very light, chalk-like rock made of the glassy shells of tiny water plants. It does not fizz in acid and feels gritty between the teeth. Look in old lake beds and some sea cliffs. It is the support for gas chromatograph columns.
  • Green leaves for a first experiment: spinach, nettle, grass or any dark leaf (Foraging Wild Food).

Chromatography paper

Paper chromatography needs paper that is pure cellulose, even, unsized and without filler. Ordinary writing paper has size and clay in it; blotting paper is too coarse and uneven.

Making it (Paper):

  1. Boil clean white cotton rag or linters for 2 hours in water with 2 % soda ash (Soda Ash and Baking Soda), rinse until the water is clear, then soak for an hour in 1 % hydrochloric acid to remove lime and iron, and rinse again in rainwater or distilled water (Distillation).
  2. Beat it to a fine, even pulp, as for paper.
  3. Form sheets on a fine mould to a dry thickness of about 0.15–0.2 mm, roughly 80–90 g per square metre. Press between clean felts and dry flat.
  4. Do not size it, bleach it with chlorine, or add any filler.

Sizes: strips 2–4 cm wide and 15–20 cm long for one or two samples; sheets 20 × 20 cm for many samples side by side.

Good and bad paper: a drop of water spreads into an even round spot in a few seconds, not a star or streak. Held to the light it looks even. An ink spot run up a strip with water rises as neat, rounded bands, not a ragged smear. Cut all strips in the same direction, since paper runs faster along its grain.

Chromatography tank

Any glass jar or tank with a tight lid, tall enough for the paper: a 1-litre jar for strips, a small glass tank for sheets. The air inside must be saturated with solvent vapour, or solvent evaporates from the paper and the spots smear.

  1. Line one wall with a sheet of filter paper soaked in the solvent.
  2. Pour in solvent to a depth of 0.5–1 cm. It must be below the line where the spots are.
  3. Close the lid and let it stand 15–30 minutes before putting the paper in.
  4. Hang strips from a hook in the lid or a paper clip on a rod, or roll a sheet into a cylinder held with thread so it stands by itself without touching the walls.

Running a paper chromatogram

  1. Draw a pencil line 2 cm from the bottom. Mark spots on it 2 cm apart, and 1.5 cm from the edges.
  2. Dissolve the sample in water or alcohol, about 1 %. Touch it on with a fine glass capillary to make spots 2–4 mm across; dry and repeat two or three times.
  3. Put the reference samples beside the unknown.
  4. Lower the paper into the tank, close it, and leave it undisturbed.
  5. When the solvent front is 1–2 cm from the top (an hour or two for water; several hours for butanol mixtures), take it out and mark the front at once in pencil.
  6. Dry it in air, or in warm air for slow solvents, and develop colourless spots (below).

Some tested systems:

To separate Solvent See the spots by
Ink and food colours Water with 1 % salt, or 1 part alcohol to 1 part water Their own colour
Amino acids Butanol, acetic acid and water, 4 : 1 : 5, shaken; use the upper layer Ninhydrin
Sugars The same butanol mixture, run for 12–24 hours Silver nitrate
Plant pigments 9 parts light petrol to 1 part acetone Their own colour

Making colourless spots visible

  • Iodine vapour. Put a few crystals of iodine in a closed jar with the dry paper or plate. In a few minutes most organic substances show as brown spots. They fade in air, so circle them at once in pencil (Iodine).
  • Ninhydrin for amino acids. Spray or dip in 0.2 % ninhydrin in alcohol or acetone and warm at about 100 °C for 3–5 minutes. Amino acids turn purple; proline turns yellow. Ninhydrin is made in a fine-chemical works from phthalic esters and selenium dioxide (Organic Synthesis and Fine Chemicals, Selenium and Tellurium). It also shows up the amino acids of your own fingerprints, so hold the paper by its edges and wear gloves.
  • Silver nitrate for sugars. Dip in a saturated solution of silver nitrate in acetone (add a few drops of water to dissolve it), dry, then spray with 2 % caustic soda in alcohol. Sugars show as dark brown spots at once. Rinse in hypo to stop the background darkening (Silver Nitrate and Silver Salts, Photography).
  • Ferric chloride, 1 % in water, turns phenols violet. That shows salicylic acid in aspirin, and the tannins in plants.
  • Ultraviolet light, on TLC plates with a fluorescent powder (below).

TLC plate

Thin-layer chromatography uses a thin coat of fine silica on glass. It is faster than paper (10–30 minutes instead of hours), gives sharper spots, and takes organic solvents and harsh sprays that paper cannot.

The silica

Make silica gel from water glass and acid as in Water Glass (Sodium Silicate). For TLC it must be very pure and very fine.

  1. Wash the gel until a few drops of the washings give no cloudiness with silver nitrate or barium chloride: all salt gone.
  2. Dry it at 150 °C and grind it in a porcelain or agate mortar.
  3. Stir the powder into water and let it settle for 1 minute. Pour off the cloudy water, which holds the fine grains, and throw away what settled. Let the cloudy water settle for an hour; keep this fine sediment. It is mostly 5–40 thousandths of a millimetre. Dry it.
  4. Mix 87 parts of fine silica with 13 parts of plaster of Paris as a binder. This is like the "silica gel G" of laboratory suppliers.

For UV viewing, also mix in 1–2 % of a green phosphor: zinc silicate or zinc sulfide activated with manganese or copper (Rare Earths, Cerium and Phosphors).

Making the plates

tape rails0.25 mm thickglass rod 1. Spread the slurry10 g silica + plaster,20–25 ml water, one stroke 110 °C 2. Set and bake30 min in air, then30–60 min at 110 °C ultraviolet lamp 3. Run and lookplate glows green;substances show dark(or brown in iodine vapour)
Fig. 2 Making and using a TLC plate. A slurry of silica and plaster is spread to an even layer, 0.25 mm thick, by a glass rod running on tape rails. After drying and baking, the plate is spotted, run in a covered jar, and the spots shown up with iodine vapour or ultraviolet light.
  1. Cut glass plates 5 × 20 cm or 20 × 20 cm, or use microscope slides for quick checks. Wash, dry, and wipe with alcohol: grease makes the layer peel.
  2. Shake 10 g of the silica and plaster mixture with 20–25 ml of water in a stoppered bottle for 30 seconds, until smooth. The plaster begins to set in 3–4 minutes, so work quickly.
  3. Spread: lay a strip of tape 0.25 mm thick (two or three layers of thick paper tape) along each long edge of the plate as rails. Pour the slurry along one end and draw a straight glass rod along the rails in one smooth stroke. For slides, simply dip two slides held back to back in a thinner slurry and draw them out slowly.
  4. Let the plates set in air for 30 minutes, then bake at 110 °C for 30–60 minutes to activate them. Store them in a dry box with dried silica gel.

Sizes: layer 0.25 mm; spots 1.5 cm from the bottom and 1 cm apart; run the solvent 8–10 cm.

Good and bad plates: a good layer is smooth, even and matt white, does not flake when the plate is tapped, and lets solvent rise in a straight front. Thick patches give lopsided fronts; a layer that falls off had too little plaster or a greasy plate; a layer that runs very slowly is too thick or the silica too fine.

Checking a medicine on TLC

To check aspirin made in Organic Synthesis and Fine Chemicals:

  1. Dissolve a pinch of your aspirin, a pinch of pure salicylic acid (the starting material), and if you have it a known good aspirin, each in 1 ml of alcohol or acetone.
  2. Spot all three on one plate, with a fourth "co-spot" of your aspirin and salicylic acid on top of each other.
  3. Run in ethyl acetate with a few drops of acetic acid (Ether, Acetone and Solvents).
  4. Dry. Look under ultraviolet, or put it in iodine vapour, then spray with ferric chloride. Salicylic acid shows violet; aspirin does not.

One spot, matching the reference, means pure. A second spot at the height of salicylic acid means an incomplete reaction or damp storage: recrystallise it. The same method checks a sulfa drug against its starting materials (Sulfa Drugs), or a herbal extract against a known plant.

Chromatography column

A column does on a large scale what a plate does on a small one, and lets you collect each substance.

Build:

  1. Tube: glass, 1–3 cm inside, 30–50 cm long, with a tap or a rubber tube and screw clip at the bottom (Laboratory Glassware). A burette will do for small work.
  2. Bottom: push a small plug of cotton or glass wool down, and cover it with 5 mm of clean sand.
  3. Packing: for 1 g of mixture use 30–50 g of silica gel (grains 0.06–0.2 mm) or alumina, or for plant pigments, powdered chalk or icing sugar. Stir it into a slurry with the first solvent, and pour it in, tapping the tube, with the tap open so the bed settles evenly. Never let the liquid fall below the top of the bed: if it runs dry, it cracks and is ruined.
  4. Top: 5 mm of sand, so pouring does not disturb the bed.

Run:

  1. Dissolve the mixture in the least solvent, and run it onto the top of the bed as a thin band.
  2. Add solvent from a dropping funnel. Start with the least polar solvent that moves anything, then make it stronger step by step, for example from light petrol, to petrol with 5 %, 10 %, 20 % acetone.
  3. Collect fractions of 10–20 ml in numbered test tubes.
  4. Check every few fractions on a TLC plate. Combine the fractions that show the same single spot, and evaporate the solvent.

A gentle push of air from a rubber bulb on top (no more than 0.3 bar, about one firm squeeze held) makes it run in minutes instead of hours. This is flash chromatography. Never pressurise a cracked or thin tube, and wrap it in tape.

Dropping funnellight petrol with 1–2 % acetone sand, 5 mm yellow xanthophylls (slow) yellow-green chlorophyll b blue-green chlorophyll a Packingchalk, icing sugar or silica orange carotene (fastest) sand on a cotton plug Tapinto numbered test tubes Bed 15–20 cmtube 1–3 cm acrossnever let it run dry solventflows down
Fig. 3 A chromatography column separating leaf pigments, as Tswett first did. Pigments from ground leaves, dissolved in light petrol, are run onto a column of chalk or icing sugar. As more solvent flows, orange carotene runs fastest and drips out first, while green and yellow bands follow more slowly.

A first experiment: Tswett's leaf pigments.

  1. Grind 10 g of dark green leaves with a little sand and 20 ml of acetone. Filter.
  2. Shake the extract with 20 ml of light petrol and 40 ml of water in a separatory funnel; the pigments move into the petrol layer on top. Keep it (Organic Synthesis and Fine Chemicals).
  3. Run it onto a column of powdered chalk or icing sugar, and wash it through with light petrol containing 1–2 % acetone.
  4. Within minutes the green band splits: an orange-yellow band of carotene runs ahead and drips out first, followed more slowly by blue-green and yellow-green chlorophyll bands and yellow xanthophyll bands. Their exact order depends on the packing and solvent.

Good and bad columns: bands should stay flat and level. Slanted bands mean a tilted column or uneven bed; channels mean air or a dried-out bed; broad, overlapping bands mean too much sample or too strong a solvent.

Gas chromatograph

A gas chromatograph separates anything that can be turned into vapour: solvents, alcohols, fuels, perfumes and gases. It is the hardest instrument here to build: it needs steady gas flow, steady heat and a sensitive electrical detector.

Carriergashydrogen,helium ornitrogen needle valve reference gas, past one wire soap-filmflow meter20–50 ml/min Injectorheated block, rubber septum;0.1–2 microlitres by syringe Oven with coiled column1–3 m of 3–6 mm tube, ±0.5 °C vent outdoors Katharometer two hot wiresin a bridge100–200 mA waterethanolmethanol Recordereach peak is one substance;its area gives the amount
Fig. 4 A simple gas chromatograph. Carrier gas from a cylinder passes a needle valve and flow meter to a heated injector, where a microlitre of sample is injected through a rubber septum. The vapours pass through a long coiled column in an oven and separate. A katharometer, two hot wires in a bridge circuit, notices each substance as it passes and the recorder draws a peak.

Parts:

Part What it is Sizes and notes
Carrier gas Hydrogen, helium or nitrogen from a cylinder 20–50 ml a minute; hydrogen gives the best signal but must be piped out of the room (Hydrogen, Oxygen and Gases, Liquid Air, Nitrogen and the Noble Gases, Pressure Vessels and Valves)
Flow control Reducing valve, needle valve, soap-film flow meter (a graduated tube with a soap film you time)
Injector A heated metal block with a silicone-rubber septum 20–50 °C hotter than the column; sample 0.1–2 microlitres from a fine syringe (Syringes and Hypodermic Needles)
Column Copper, steel or glass tube, 3–6 mm across, 1–3 m long, coiled Packed with crushed diatomaceous earth or firebrick, sieved to 0.18–0.25 mm, coated with 5–15 % by weight of a non-volatile liquid
Oven Insulated box with a fan and heater Held within ±0.5 °C by a thermostat; 30–250 °C
Detector Katharometer or flame ionisation Below
Recorder Chart recorder, or a galvanometer read every 5 seconds Measuring Electricity

Coating the packing: dissolve the liquid (silicone oil, a heavy paraffin oil, or a polyethylene glycol wax) in a volatile solvent, stir in the sieved earth, and evaporate the solvent gently with stirring. Pour it into the coiled tube while tapping, and plug both ends with glass wool. Bake the column at its top temperature with gas flowing overnight before use. Non-polar liquids (paraffin, silicone oil) separate by boiling point; polar ones (glycol waxes) separate alcohols and water well.

The katharometer (thermal-conductivity detector) is the one to build first. It is a brass block with two small bores. In each is a thin platinum or tungsten wire heated by a steady current of 100–200 mA (Tungsten and Filament Wire). Pure carrier gas flows past one wire; gas from the column past the other. The two wires form two arms of a Wheatstone bridge (Measuring Electricity). When a vapour comes out of the column, it carries heat away from its wire less well than hydrogen or helium does, the wire warms, its resistance rises, and the bridge goes out of balance. The recorder draws a peak. It detects down to roughly one part in ten thousand.

The flame ionisation detector burns the column gas in a small hydrogen flame between electrodes at 150–300 V. Organic vapours make ions, and a tiny current flows. It is a thousand times more sensitive but needs a very sensitive amplifier (Amplifiers and Oscillators).

Using it:

  • Each substance comes out at its own retention time, measured from injection. Inject pure substances to learn their times.
  • The area of a peak is proportional to the amount. Calibrate with known mixtures: for methanol in spirits, make up spirits with 0.1 %, 0.5 % and 1 % methanol and compare.
  • Gases (oxygen, nitrogen, methane, carbon dioxide) separate on a column packed with zeolite or charcoal grains, with no liquid coating (Water Softening and Ion Exchange, Activated Charcoal).

Good and bad: a good instrument gives sharp, symmetrical peaks on a flat baseline, and repeat injections agree within a few percent. A wandering baseline means unsteady oven or flow; tailing peaks mean a cold injector or poor packing.

How to tell it worked

  • Reference first: a known pure substance gives one clean spot or peak at the expected place.
  • Repeatable: the same sample run twice gives the same Rf within about 0.05, or the same retention time within 1–2 %.
  • Co-spot test: an unknown spotted on top of a reference gives one spot if they are the same substance, and two if not.

Note Troubleshooting. Spots streak into long smears → too much sample, or an acid or base sticking to the paper. Use less; add a few drops of acetic acid or ammonia to the solvent. Solvent front is crooked → the paper touched the wall, the plate's layer is uneven, or the tank was not saturated. Everything stays on the line → solvent too weak; add a more polar one (alcohol, acetone, acetic acid). Everything runs with the front → solvent too strong; dilute it with a less polar one. No peaks on the gas chromatograph → the septum leaks, the injector is too cold, or the bridge current is off.

Dangers

Danger Solvent fires. Light petrol, acetone, ether and alcohols catch fire from a flame or spark across a room, and their vapour flows along benches. No flames in the room while solvents are open. Dry plates in a draught, not over a burner. Hydrogen carrier gas must be vented outdoors (Ether, Acetone and Solvents, Fire Extinguishers and Alarms).

  • Do not use benzene (causes leukaemia) or chloroform and carbon tetrachloride (liver poisons), which old recipes name. Toluene, ethyl acetate and light petrol replace them.
  • Butanol, acetic acid, ninhydrin, silver nitrate and iodine irritate, stain or burn; work in a draught and wear gloves (Iodine, Silver Nitrate and Silver Salts).
  • Fine silica dust harms lungs; grind and mix it wet, and wear a damp cloth over mouth and nose (Water Glass (Sodium Silicate)).
  • Ultraviolet lamps burn eyes. Look at plates through ordinary glass, never into the lamp (Arc Lamps, Neon and Fluorescent Lights).

What this unlocks

Purity checks for Making Medicines and Pharmacy: Tablets, Capsules, Ointments and Inhalers; dye and ink analysis; sugar and amino-acid analysis for Nutrition and Deficiency Diseases, The Medical Laboratory work and Cells, Life and Evolution; safe spirits; fuel and gas analysis; the ion-exchange separations of Separating the Rare Earths. Later, liquids pumped at high pressure through very fine beads give high-performance liquid chromatography, the workhorse of drug factories.

How it was first done

Friedlieb Runge let dye mixtures spread on blotting paper into coloured rings in the 1850s. The Russian-Italian botanist Mikhail Tsvet (Tswett) separated leaf pigments on columns of chalk and sugar, described them in 1903–06, and named the method "chromatography", colour-writing. Archer Martin and Richard Synge in Leeds invented partition chromatography in 1941, and with Raphael Consden and A. H. Gordon separated amino acids on paper in 1944. Frederick Sanger used paper chromatography to work out the order of amino acids in insulin by 1955. Thin layers were tried by Izmailov and Shraiber in Kharkov in 1938 and made a standard method by Egon Stahl in 1956–58. Martin and Anthony James built the first gas–liquid chromatograph in 1952; Martin and Synge received the Nobel Prize that year.