◆ Rebuild

Part 10 · Machines

Heat Exchangers

Move heat from one fluid to another through a thin wall without letting them mix — the coil in a tank, the shell full of tubes, the pack of pressed plates and the finned radiator. Why running the two streams in opposite directions matters so much, how to size an exchanger from its area and temperature difference, how to build and test each kind, and how to keep them clean in the brewery, the dairy, the engine room and the chemical works.

Difficulty
●●●●●
Time
An afternoon for a cooling coil; one to three weeks for a shell-and-tube exchanger; a press shop and months for plate exchangers
Steps from zero
40 prerequisites →

You need first

Boilers and Pressure VesselsPressure Vessels and Valves

This unlocks

Cooling Towers and Spray PondsGeothermal, Tidal and Wave Power

Raw materials

sandrubber tree
The full path from nothing — 40 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. Charcoal
  9. Pottery
  10. The Kiln
  11. Hides and Leather
  12. Bricks
  13. Lime
  14. Mercury
  15. Lye and Potash
  16. The Wheel and Axle
  17. Firebrick and Refractories
  18. Glass
  19. Bellows
  20. The Lathe
  21. Gears
  22. Iron (the Bloomery)
  23. Copper Smelting
  24. Laboratory Glassware
  25. The Waterwheel
  26. Blacksmithing
  27. The Blast Furnace and Cast Iron
  28. Magnets
  29. The Barometer
  30. Sheet Metal and Rolling
  31. The Steam Engine
  32. Copper Wire
  33. Boilers and Pressure Vessels
  34. The Generator
  35. The Electric Arc Furnace
  36. Calcium Carbide and Acetylene
  37. Welding
  38. Metal Pipes and Tubes
  39. Pressure and Vacuum Gauges
  40. Pressure Vessels and Valves
  41. Heat Exchangers

Do them roughly in this order. See it on the tech tree →

Why it matters

A brewer must cool boiling wort to 20 °C fast, before wild bacteria take it. A dairy heats milk to 72 °C to kill germs and must then chill it to 4 °C. An engine must throw away a third of its fuel's heat or seize; a steam turbine makes far more power if its exhaust is condensed (The Steam Turbine); a still must turn its vapour back to liquid (Distillation).

In each case two fluids must trade heat without touching: cooling water must not get into the beer, ammonia must not get into the milk. The device that does this is a heat exchanger: a thin wall of metal with one fluid on each side. Done well, it also lets you recover heat that would be thrown away — the hot pasteurised milk warming the cold raw milk coming in — and that can cut the fuel bill by three quarters.

How it works

Heat flow through a wall

Heat goes from the hot fluid, through a thin layer of slow-moving fluid clinging to the wall, through the metal, through another clinging layer, and into the cold fluid. The metal is rarely the problem: copper passes heat more than 600 times better than still water, and even steel about 80 times better. The clinging layers are the problem, and they thin out when the fluid moves fast and churns. So a good exchanger makes both fluids move briskly and turbulently past the wall — and keeps the wall clean, because a millimetre of scale can halve its output.

All exchangers obey one rule:

heat moved (W) = U × A × mean temperature difference

A is the wall area in m². U is how well the whole wall passes heat, in watts per m² per °C. Rough values for clean surfaces:

Fluids, type of exchanger U (W per m² per °C)
Water to water, shell-and-tube 800–1,500
Water to water (or milk, wort), pressed plates 3,000–6,000
Condensing steam to water 1,500–4,000
Water to oil 100–350
Water to air, finned tube (per m² of fin surface) 25–50
Air to air or gas to air, plain tube or plate 10–40

Liquids flowing in tubes should move at 1–2 m/s; much slower and U drops and dirt settles; much faster and copper tubes erode and the pump works hard.

Counterflow

Parallel flowboth enter at the same end Counterflowthey enter at opposite ends hot fluid in the inner tube, cold water around it hot in 95 °Ccold in 12 °C hot out 45 °Ccold out 35 °C 9512 4535 °C along the exchanger cold can never pass 45 °C hot in 95 °Ccold out 57 °C hot out 25 °Ccold in 12 °C 9557 2512 °C along the exchanger cold water leaves hotter than the hot fluid leaves
Fig. 1 Parallel flow and counterflow. In parallel flow both fluids enter at the same end and their temperatures approach each other but can never cross: the cold fluid always leaves cooler than the hot one. In counterflow the cold fluid meets the hottest hot fluid last and can leave hotter than the hot fluid leaves.

If both fluids enter at the same end and run the same way (parallel flow), they race toward the same middle temperature and stop there: the cold water can never leave hotter than the hot fluid leaves. Send them opposite ways (counterflow) and the cold water meets the hottest fluid just before it leaves. It can come out nearly as hot as the hot fluid went in, and the hot fluid can come out nearly as cold as the cold fluid went in. Counterflow gives more heat from the same area and lets you recover most of the heat. Always use counterflow unless there is a strong reason not to.

Sizing: an example

Cool 600 litres an hour of wort from 95 °C to 25 °C with well water at 12 °C, using 900 litres an hour of water.

  1. Heat to remove. Wort needs about 4 kJ per kg per °C. 600 kg/h is 0.167 kg/s, so 0.167 × 4 × 70 = 47 kW.
  2. Water outlet. Water takes 4.2 kJ per kg per °C. 900 kg/h is 0.25 kg/s, so its rise is 47 ÷ (0.25 × 4.2) = 45 °C: it leaves at 57 °C — hot enough to use for cleaning or the next brew. (In parallel flow this is impossible: the water could never get above 25 °C.)
  3. End differences in counterflow: at the hot end 95 − 57 = 38 °C; at the cold end 25 − 12 = 13 °C.
  4. Mean difference. The proper value is the log mean: (38 − 13) ÷ ln(38 ÷ 13) = 23 °C. Without logarithms (Calculating Aids), take the average of the two ends and subtract about a tenth if one is more than twice the other: (38 + 13) ÷ 2 = 25.5, less a tenth, ≈ 23.
  5. Area. A = 47,000 ÷ (U × 23). With plates (U = 3,000): 0.7 m². With a shell-and-tube (U = 1,000): 2 m².
  6. Allow for dirt. Add 20–30% to the area.

What you need

Item Notes
Copper or brass tube, 10–25 mm the best tube for water, milk, wort and steam (Copper Smelting, Zinc and Brass, Metal Pipes and Tubes)
Steel tube and plate for oil, ammonia, high pressures and big sizes (Steel)
Copper or brass sheet, 0.1–1 mm fins, plates
Thick brass or steel plate, 20–40 mm tube sheets
Rubber gaskets (Rubber); or compressed asbestos-free fibre with oil, or soft copper for high heat (Packing, Gaskets and Seals)
Dry sand, or melted rosin or lead filling tubes so they bend without kinking
Solder and brazing alloy Soldering and Brazing
A drilling machine and a lathe for tube sheets (Drills and Boring, The Lathe)
Thermometers, a bucket and a watch testing (The Thermometer)

The cooling coil

The simplest exchanger is a cooling coil: a tube wound into a spiral and set in a tank, with one fluid inside the tube and the other in the tank. It needs no tools beyond what bends a tube.

The immersion wort chiller. For a 20–25 litre brew, wind 10–15 m of 10–12 mm copper tube into a coil about 25 cm across that fits inside the boiling pot, with both ends rising above the rim and bent over the side. Drop it in for the last 15 minutes of the boil to sterilise it, then run cold water through it and stir the wort gently. It cools 20 litres from boiling to 25 °C in 20–30 minutes with water at 10–15 °C. Cooling coils also chill milk in a churn, cool the condensate of a still, and heat water in a tank from a boiler (a calorifier, as in the hot water cylinder of Hot Water and Central Heating).

Bending tube without kinking:

  1. Anneal copper or brass by heating to dull red and letting it cool (or quenching it): it becomes soft.
  2. Fill it with dry fine sand, rammed tight, and plug both ends with wooden bungs. The sand holds the walls round as it bends. For tight bends, fill with melted rosin or lead instead and melt it out afterwards.
  3. Wind it slowly round a wooden drum or a log of the right diameter, a little at a time. Keep the bend radius at least 3 times the tube diameter with sand filling.
  4. Shake out every grain of sand and blow through it.

A tube-in-tube (double-pipe) exchanger — one tube inside another, with the fluids flowing opposite ways — gives true counterflow and good speed in both channels. It is described in Heat Pumps and District Heating; for a brewery, 6–10 m of 12 mm copper inside 22 mm copper or rubber hose, wound into a coil, cools wort in a single pass on its way to the fermenter. The laboratory Liebig condenser is the same thing in glass (Laboratory Glassware).

The jacketed vessel. A second wall round a pot or tank with steam or water flowing in the gap heats or cools the contents without any coil inside to clean. Mash tuns, cheese vats and chemical reactors use jackets (Dairy and Cheese).

The shell-and-tube heat exchanger

Tube fluid ine.g. cooling water Bafflescut away a quarter; spaced0.3–0.5 × shell diameter Shell fluid inhot oil, steam, wort… Return head Partitiontwo passes Tube fluid out Shell fluid out Shell Tubes12–25 mm across Tube sheetthick, drilled Tube expander grooves in the hole hardened rollers in a cage spread the tube 5–8% into the hole tapered mandrel: push and turn
Fig. 2 A shell-and-tube heat exchanger, cut open. One fluid flows through the bundle of tubes, here making two passes, turned round by the partition in the head; the other fluid flows through the shell outside the tubes, zigzagging past the baffles. The tube ends are rolled tight into the thick tube sheets.

This is the workhorse of industry: engine jacket-water coolers, oil coolers, the surface condensers of steam engines and turbines, ammonia condensers, acid coolers and feedwater heaters. It packs a large area into a strong cylinder, takes high pressures, and comes apart for cleaning.

The parts

  • Tubes: 12–25 mm outside, 1–1.5 mm wall for copper and brass, 2–2.5 mm for steel. Straight, 1–5 m long.
  • Tube sheets (tube plates): two thick plates drilled with a hole for every tube. Thickness at least the tube's diameter, and not less than 20 mm.
  • Shell: the outer cylinder, a steel or copper pipe or rolled plate, with an inlet near one end and an outlet near the other.
  • Baffles: plates across the shell, each cut away on one side (about a quarter of the diameter), alternately top and bottom, so the shell fluid zigzags across the tubes instead of sliding along them. Space them 0.3–0.5 times the shell diameter apart. Tie rods hold them in place and stop the tubes vibrating.
  • Heads (channels): bolted end caps. A partition in one head makes the tube fluid go down half the tubes and back through the others (two passes), which doubles its speed.

Which fluid where? Put inside the tubes whatever is dirtier (it is easier to rod out straight tubes), at higher pressure (small tubes hold pressure easily), or corrosive (only the tubes need be of the costly metal). Put on the shell side condensing steam or vapour, and the cleaner fluid.

Laying out the tubes. Space the tube centres 1.25 times the tube diameter, on a triangular pattern. Count the tubes from the area: each tube gives π × diameter × length of surface. For 2 m² of 19 mm tube 1.5 m long, each tube gives 0.09 m², so you need 23 tubes, which fit in a shell about 15 cm across. Then check the speed: if the tube fluid would move slower than about 1 m/s, use fewer, longer tubes or more passes.

Building one

  1. Tube sheets. Mark out the pattern on both sheets clamped together and drill them together, so the holes line up. Drill each hole 0.2–0.4 mm larger than the tube. In each hole cut two shallow grooves about 3 mm wide and 0.4 mm deep with a small boring tool; the tube metal will be pressed into them.
  2. Baffles. Cut from 3–6 mm plate, drilled from the same template with holes about 0.8 mm larger than the tubes, and cut away on one side.
  3. Assemble the skeleton: one tube sheet, the tie rods with spacer tubes between the baffles, the second sheet.
  4. Thread in the tubes, each standing 3 mm proud of both sheets.
  5. Expand the tubes into the sheets (below). Small exchangers with brass sheets can instead have the tubes soldered or brazed in (Soldering and Brazing).
  6. Slide on the shell and weld or bolt it to the tube sheets. In a fixed design the shell is welded to both sheets; it is simplest, but the shell side cannot be opened.
  7. Bolt on the heads with gaskets.

The tube expander

A tube expander squeezes the tube end outwards until it grips the hole like a rivet, tight enough to hold water at high pressure. It has three small hardened steel rollers held in slots in a cage that fits inside the tube, and a long tapered mandrel (taper about 1 in 25) that runs down the middle between them. Pushing and turning the mandrel with a wrench drives the rollers outwards as they roll round the inside of the tube, thinning the wall and spreading it into the hole and its grooves. Stop when the wall has thinned by about 5–8% (measure the bore before and after); more and the tube cracks, less and it leaks. Make the rollers and mandrel from tool steel, harden and temper them (Steel). Finish by flaring the projecting tube ends slightly with a cone punch.

Expansion

When hot and cold fluids differ by more than about 50 °C, the tubes and the shell grow by different amounts, and in a fixed exchanger the tubes are pulled out of their sheets or buckle. Then use one of:

  • U-tubes: each tube bent into a long U, both ends in one tube sheet; the bundle grows freely. (They cannot be rodded clean round the bend.)
  • A floating head: one tube sheet is free to slide inside the shell in a packed gland (Packing, Gaskets and Seals).
  • An expansion bellows — a ring of corrugated sheet — welded into the shell.

The plate heat exchanger

hot, flowing down cold, flowing up hot, flowing down cold, flowing up Plates, opened outrubber gasket round the edge and round the two ports each fluid must pass by The frameplates squeezed by tie bolts fixed head plate (left),movable plate (right) Finned radiator filler top tank: hot water in bottom tank: cooled water out Looking down into the coreair passes between the tubes Flat tubes10–15 × 2–3 mm Finscopper 0.1 mm,2–3 mm apart
Fig. 3 Above, a plate heat exchanger opened out. Each pressed plate has a rubber gasket round its edge and round two of its four corner ports; every second plate is turned upside down, so the hot and cold fluids fill alternate gaps and run opposite ways. The pack is squeezed between a fixed and a movable frame plate by long bolts. Below, a finned radiator core: flat tubes carrying water, with thin zig-zag fins soldered between them for the air.

A plate heat exchanger is a pack of thin metal plates, each pressed with a pattern of ridges, clamped together in a frame with rubber gaskets between them. The fluids flow in thin sheets, 2–5 mm thick, between alternate pairs of plates. The ridges — usually a herringbone (chevron) pattern — make the thin streams churn violently even at low speed, so U is three to five times that of a shell-and-tube. A plate exchanger the size of a suitcase does the work of a shell-and-tube the size of a car, and it opens in minutes for cleaning and inspection. That is why every dairy and brewery uses them.

The parts:

  • Plates: 0.5–0.8 mm stainless steel, pressed with ridges 2.5–4 mm deep, with a hole (port) in each corner. The ridges of neighbouring plates cross and touch at hundreds of points, holding the plates apart.
  • Gaskets: rubber strips in a groove round each plate, encircling the flow area and two of the ports. One fluid flows across this plate between those two ports; the other fluid's ports are ringed off, so it passes straight through to the next gap.
  • Arrangement: every second plate is hung upside down, so the gaps alternate hot, cold, hot, cold, flowing opposite ways.
  • Frame: a fixed head plate with the pipe connections, a movable pressure plate, bars above and below on which the plates hang, and long tie bolts.

Building one, honestly. Pressing thin stainless steel plates needs a big press and a pair of matched dies cut accurately in hard steel (Presses, Punches and Dies); the gaskets need a moulded rubber (Rubber). This is factory work. The first plate exchangers, made for dairies in the 1920s, are said to have used thicker plates cast in gunmetal (a bronze) and machined. A workshop can start smaller:

  1. Cut plates of 1 mm copper or brass, 15 × 50 cm, with a 3 cm port near each corner.
  2. Press or hammer a pattern of diagonal ridges 2–3 mm high into each plate over a hardwood or cast-iron former, ridges at 45° across the plate, alternating direction on alternate plates.
  3. Cut gaskets 3–4 mm thick from sheet rubber: an outer frame round the edge, plus rings to isolate two ports. Glue them to the plates.
  4. Hang 10–20 plates in a frame of two thick steel end plates and four bolts, and tighten evenly to the pack length where the ridges just touch and the gaskets are squeezed by about a quarter. Over-tightening crushes the gaskets and bends the plates.
  5. Test with water at 1.5 times the working pressure (keep it below about 3 bar for this home-made kind).

The pasteuriser. A dairy plate pasteuriser has several sections in one frame, divided by connector plates:

  1. Regeneration. Cold raw milk at 4 °C is warmed to about 60–65 °C by the hot milk leaving the holder.
  2. Heating. Hot water at 75–80 °C brings it to 72 °C.
  3. Holding tube. A length of pipe sized so the milk takes at least 15 seconds to pass through. A thermometer at its end works a diversion valve: if the milk is under 72 °C, it is sent back to the start, not forward.
  4. Back through regeneration, giving up its heat to the incoming milk and cooling to 15–20 °C.
  5. Cooling. Chilled water brings it to 4 °C.

The regeneration section recovers 80–90% of the heat. Keep the pasteurised milk at higher pressure than the raw milk in the regeneration section (pump it, or put the booster pump after the holder): then if a plate cracks, clean milk leaks into raw milk, never raw into clean. See Dairy and Cheese.

The finned radiator

Air passes heat 50–100 times worse than water, so when one fluid is air, its side needs far more area. Fins — thin metal sheets fixed to the outside of the tubes — give it.

The engine radiator is the commonest example. Hot water from the engine's jacket enters a top tank, falls through many narrow flat tubes to a bottom tank and returns to the engine. Between the tubes, thin zig-zag or flat fins of copper fill the space, and the fan or the vehicle's motion pushes air through. Sizes:

Part Size
Tubes flattened brass, 10–15 mm × 2–3 mm, wall 0.15–0.3 mm, spaced 10–12 mm apart
Fins copper strip 0.07–0.15 mm thick, 2–3 mm apart (5–8 mm where there is dust, lint or frost)
Core depth 4–8 cm
Size about 0.1 m² of core face per 10 kW of engine power, with a fan

An engine sends about as much heat into its cooling water as it gives out as work (The Internal Combustion Engine), so a 30 kW engine needs a radiator that sheds about 30 kW.

Building a radiator core:

  1. Fold strips of copper 0.1 mm thick into a zig-zag with folds 2.5 mm apart, as wide as the core is deep, using a pair of gear-like toothed rollers or by folding over a comb of thin steel blades.
  2. Flatten brass tubes, or fold and solder them from brass strip with a lock seam.
  3. Stack tubes and fin strips alternately in a jig, clamp them, and dip or sweat the whole core with soft solder so every fold is joined to its tube. Solder the tube ends into holes punched in the tank plates (Sheet Metal and Rolling, Soldering and Brazing).
  4. Test under water with air at 0.5–1 bar: bubbles show leaks.

Plate-fin coils. For air conditioning coils, heaters and refrigerating evaporators, thin sheets of copper or aluminium are punched with rows of holes, each with a short collar; stacked on round copper tubes 10–16 mm across, they are locked on by pulling a hard steel bullet (a ball slightly larger than the bore) through each tube to expand it. U-bends are soldered on the ends. The cooling coil of an air handling unit (Ventilation and Air Conditioning) is built this way.

Wound fins — a thin strip wound edgewise in a spiral round a tube in a lathe, its inner edge crimping as it goes — make strong finned tubes for steam-heated air heaters and driers.

Fouling and cleaning

Every exchanger gets dirty on its hot surfaces, and dirt is an insulator. Know what you are fighting:

  • Scale — calcium carbonate from hard water, worst above about 60 °C. Soften the water or keep the cooling water side below that, and keep it moving at 1 m/s or more. Remove scale with 5–10% hydrochloric acid containing an inhibitor (a little glue or flour slows its attack on the metal) or with citric acid or vinegar for small jobs; rinse well. See Hydrochloric Acid.
  • Milkstone and protein in dairies, beer stone in breweries. Clean every day by circulating, without opening ("cleaning in place"): a water rinse; 1–2% lye at about 75 °C for 20–30 minutes to dissolve fat and protein (Lye and Potash); a rinse; 0.5–1% nitric or phosphoric acid at 60–70 °C for 10–15 minutes to dissolve mineral deposits (Nitric Acid, Phosphoric Acid and Phosphates); a final rinse; and a sanitising rinse just before use.
  • Slime and mud in river- or sea-water coolers. Strain the water, keep the speed up, and rod out the tubes with a brush on a long rod when the heads are off.
  • Oil and tar on steam and gas sides: lye, or a solvent (Ether, Acetone and Solvents).

Log outlet temperatures and pressures weekly; a slow creep tells you when to clean.

How to tell it worked

  • Measure the duty. Time how long it takes to fill a bucket at each outlet, and read thermometers at all four connections. Heat out of the hot side (flow × 4.2 × its temperature drop, for water) should equal heat into the cold side within about 10%. If it does not, a thermometer is wrong or there is a leak.
  • Compare with the design. Work out U from heat ÷ (area × mean temperature difference). If it is far below the table, the fluid is too slow, the baffles leak round their edges, or the wall is dirty.
  • Leak test. Fill one side with water under 1.5 times its working pressure (Pressure Vessels and Valves) with the other side open and dry, and watch for drips at the tube ends, gaskets and other side for an hour. Then test the other side.
  • Counterflow check. In a working counterflow exchanger, the cold outlet should be hotter than the hot outlet. If it is not, the pipes may be connected for parallel flow.

Note Troubleshooting. Output falls slowly over weeks → fouling. Clean, and treat the water. Output poor from the start → fluids too slow (add passes or baffles), wrong connections (parallel flow), air trapped at the top of a shell (fit a vent cock at the highest point), or condensate flooding the bottom of a steam heater (fit a steam trap). Water in the oil, milk in the water, ammonia smell in the cooling water → a leaking tube or gasket. Pressure test each side; plug a bad tube at both ends with tapered brass plugs (up to a tenth of the tubes can be plugged) and replace it later. Bangs and shudders in a steam heater → water hammer: condensate collecting where steam meets it. Drain and trap the low points, and open steam valves slowly.

Dangers

Danger Bursting and steam. A heat exchanger is a pressure vessel on both sides. Each side needs a pressure test, and a relief valve if its supply could ever exceed what it was tested for. A closed-off side full of liquid that gets heated bursts: liquid cannot compress, and heating it a few degrees raises the pressure enormously. Never shut both valves on a side while the other side is hot.

Warning Cross-contamination. A pinhole lets one fluid into the other. Keep the fluid that must stay clean (drinking water, pasteurised milk, food) at the higher pressure, so any leak runs away from it, and test exchangers handling food regularly. Never use an exchanger that has carried poisons (ammonia, oils, chemicals) for food afterwards.

  • Burns. Lag steam-heated exchangers and their pipes (Insulation and Keeping Buildings Warm or Cool).
  • Freezing. Water left in a tube bundle in frost splits it. Drain it.
  • Cleaning chemicals. Hot lye and acid blind and burn. Wear eye protection and rubber gloves, add them to water, never the reverse, and never mix acid cleaners with bleach.

What this unlocks

Heat exchangers make the surface condenser that doubles a steam plant's power (The Steam Turbine); the engine radiator (The Motor Vehicle) and the intercooler of a turbocharged engine (Rotary Compressors and Turbochargers); the pasteuriser and the brewery's wort cooler (Beer, Wine and Cider); the condensers and evaporators of every refrigerator, air conditioner and heat pump (Ice and Refrigeration, Heat Pumps and District Heating, Ventilation and Air Conditioning); the coolers of the acid and ammonia works (Sulfuric Acid, Ammonia); and heat recovery anywhere heat is thrown away.

How it was first done

Distillers cooled their vapour pipes with water for centuries: the coiled worm in a tub of water is the oldest heat exchanger (Distillation). The water-jacketed glass condenser was described by Christian Weigel in Germany in 1771 and made famous by Justus von Liebig's laboratory in the 1830s. The separate condenser of James Watt's engines sprayed water straight into the steam; the surface condenser, keeping the boiler's pure water apart from dirty sea water in a shell full of tubes, was patented by Samuel Hall in England in 1834 and became standard on steamships later in the century, making the shell-and-tube exchanger an industrial product.

Wilhelm Maybach's honeycomb radiator, with many small tubes and air passages, cooled the 1901 Mercedes and set the pattern for car radiators. In 1923 Richard Seligman, founder of the Aluminium Plant & Vessel Company in London, introduced the first commercially successful plate heat exchanger, built for pasteurising milk; pressed stainless steel plates followed in the 1930s, and the design spread through the dairy, brewing and food industries.

Source: content/entries/mechanics/heat-exchangers.md