◆ Rebuild

Part 13 · Electricity

Thermocouples and Thermoelectricity

Join two different metals and heat one junction, and a small, steady voltage appears that rises with the temperature. That is the thermocouple — the way almost every furnace, kiln and engine has been measured since the 1890s. How to choose the metals, make the wires and junction, calibrate it against melting metals, read furnace heat to a few degrees, build thermopiles that sense radiant heat or give a steady current, and use a flame to hold a gas valve open.

Difficulty
●●●●●
Time
An afternoon for a copper–constantan couple; a day to make, calibrate and fit a furnace thermocouple; a week for a thermopile generator
Steps from zero
19 prerequisites →

You need first

Copper WireMeasuring Electricity

This unlocks

—
The full path from nothing — 19 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. Charcoal
  9. Pottery
  10. Hides and Leather
  11. Fermentation
  12. Bellows
  13. Copper Smelting
  14. Iron (the Bloomery)
  15. Blacksmithing
  16. The Battery
  17. Copper Wire
  18. The Electromagnet
  19. Measuring Electricity
  20. Thermocouples and Thermoelectricity

Do them roughly in this order. See it on the tech tree →

Why it matters

A glass The Thermometer breaks at a few hundred degrees. Above that, potters, smiths, glassmakers and steelmakers judged heat by the colour of the glow, by clay cones (Pyrometric Cones and Kiln Temperature) and by pieces of metal that melt — good methods, but rough, slow and hard to write down (The Thermometer, The Kiln). A thermocouple — two wires of different metals joined at the tip — reads the heat inside a furnace directly, continuously and from a distance, to within a few degrees, at anything from freezing to 1,500 °C.

That lets you:

It needs only two kinds of wire and a sensitive meter (Measuring Electricity), so it is one of the most useful things you can make once you have copper wire.

How it works

The Seebeck effect

Make a loop of two different metals — say copper and iron — joined at both ends. Heat one joint and keep the other cool. A current flows round the loop for as long as one joint is hotter than the other. Break the loop and put a sensitive meter in the gap: it reads a small voltage, which grows with the difference in temperature between the hot joint (the hot junction, or measuring junction) and the cool one (the cold junction, or reference junction).

The voltage is tiny: a few hundredths of a thousandth of a volt per degree — measured in microvolts per degree (µV/°C), or in millivolts (mV) in all. But it is steady and repeatable: the same two wires at the same temperatures always give the same voltage.

Furnace Hot junction : fused bead Sheathiron or porcelain tube Iron wire(solid) Constantan wire(dashed) clay beads Cold junctionboth joints in ice water, 0 °C Copper leads Millivoltmeter mV 0–50 mV, highresistance; read yourcalibration curve
Fig. 1 A furnace thermocouple. The hot junction sits inside the furnace in a protective tube; two different wires, insulated by clay beads, run out to a cold junction kept in ice water; copper leads carry the small voltage to a millivoltmeter.

Which metals?

Each metal has a place in the thermoelectric series. The farther apart two metals are in this list, the more voltage they give together:

Metal (near room temperature) µV/°C, compared with platinum
Antimony +47
Iron +19
Copper, silver, gold +6 to +7
Platinum 0
Nickel −15
Constantan (55% copper, 45% nickel) −35
Bismuth −72

Subtract to get a pair's voltage: iron against constantan gives about 19 − (−35) = 54 µV/°C; copper against constantan about 42 µV/°C; bismuth against antimony nearly 120 µV/°C.

The best pairs give a large, steady voltage that rises evenly with temperature, and survive the heat:

Pair About Good up to Notes
Copper – constantan 40–43 µV/°C 350 °C Ovens, boilers, dryers, low heat. Copper oxidises above this
Iron – constantan 52–55 µV/°C 750 °C The best first furnace couple. Iron rusts away above this
Nickel-chromium – nickel-aluminium about 41 µV/°C 1,200 °C Needs chromium and aluminium alloys (Alloy and Stainless Steels, Aluminium)
Platinum – platinum with 10% rhodium 6–12 µV/°C 1,500 °C Glass and steel furnaces; very costly but very stable
Copper – iron 12 µV/°C, falling 250 °C only Easy, but its voltage stops rising at about 270 °C and then falls: never use it for furnaces
Bismuth – antimony about 110 µV/°C 150–200 °C Very sensitive; for thermopiles that detect radiant heat

Two rules that make it practical

  1. Only the ends matter. The voltage depends only on the temperatures of the two junctions, not on how hot the wires are along the way. So the wires can pass through a furnace wall and out across a hot room.
  2. A third metal adds nothing if both its ends are at the same temperature. So you can solder or braze the junction, and join copper leads to run to the meter, as long as the two joins where the copper meets the thermocouple wires are at the same temperature — side by side in the cold-junction bath.

The reverse: the Peltier effect

Drive a current through a junction of two metals and it warms or cools slightly, depending on the direction. With metal pairs the effect is weak; with certain semiconductor crystals it is strong enough to freeze water and is used for small coolers (Semiconductors and the Transistor, Ice and Refrigeration).

What you need

Item Notes
Iron wire, 1.5–3 mm for furnaces, 0.5 mm for quick readings Soft, clean iron (Iron and Brass Wire)
Constantan wire, same size 55 parts copper to 45 nickel by weight (below)
Copper wire For leads and copper–constantan couples (Copper Wire)
Insulators Two-hole clay tubes or strings of fired clay beads (Pottery, Firebrick and Refractories)
Protective sheath Iron pipe closed at one end (to 800–900 °C), or a fired porcelain or fireclay tube (higher) (Stoneware and Porcelain)
Millivoltmeter A moving-coil meter reading 0–50 mV, with high resistance (below) (Measuring Electricity)
Cold-junction flask An insulated jar of crushed ice and water
Pure metals for calibration Tin, lead, zinc, aluminium, a little silver
Small crucibles and charcoal powder For melting the calibration metals (Metal Casting)

Where to find it

  • Nickel for constantan comes from garnierite — a soft, bright apple-green ore in weathered red-brown soils over dark green serpentine rock (New Caledonia, the Urals, Oregon) — or from sulfide ores of the same rock family; smelting and refining it is in Nickel and Cobalt.
  • Copper: native copper and green and blue ores (Copper Smelting). Iron: bog iron, magnetite and other ores (Iron (the Bloomery)).
  • Antimony from stibnite — lead-grey, needle-like crystals that melt in a candle flame; bismuth from silvery, pinkish native bismuth and from bismuthinite (Antimony and Bismuth).
  • Platinum — heavy, silvery-grey grains in some river gravels with gold (Platinum and the Platinum Metals); rhodium for the platinum–rhodium couple is separated from the same crude metal (Palladium, Rhodium and Iridium).
  • Zinc from calamine and sphalerite (Zinc and Brass).

Step by step: an iron–constantan furnace thermocouple

1. Make the constantan

  1. Melt 55 parts copper in a covered crucible under a layer of charcoal powder, in a furnace that reaches about 1,300 °C (white-yellow heat) (Metal Casting).
  2. Add 45 parts nickel in small pieces. Nickel melts at 1,455 °C, but it dissolves in hot molten copper. Stir with a fireclay rod; skim.
  3. Cast into a rod mould. Draw it into wire through steel draw plates, annealing it at a red heat every few passes (Iron and Brass Wire).
  4. Keep a note of each batch. Every batch is a little different, so calibrate each one (step 4).

Without nickel, a copper – iron couple will do for ovens and drying below 250 °C, and that is all.

2. Make the junction

  1. Cut a length of iron wire and of constantan wire, each long enough to reach from the hottest point in the furnace to outside it, plus 20–30 cm.
  2. Clean 3 cm at one end of each, bright with emery.
  3. Twist the two ends together tightly for 2–3 turns.
  4. Fuse the tip. Connect the twisted pair to one terminal of a 12–24 V battery or a welding transformer (Welding); connect a pointed carbon rod (from an arc lamp or a battery) to the other. Touch the rod to the very tip and draw it away: the arc melts the tip into a small, round, shiny bead. Cut off any loose ends below the bead. For use below about 700 °C you can instead braze or silver-solder the twist (Soldering and Brazing).

3. Insulate, sheath and connect

  1. Thread both wires through two-hole clay tubes or strings of small fired clay beads, so the wires cannot touch each other anywhere except at the bead. Make tubes by extruding fine clay through a die with two pins, drying and firing them (Pottery).
  2. Slide the whole into a protective sheath closed at the hot end, with the bead touching the end. Bare iron and constantan wires corrode quickly in furnace gases; the sheath gives them a long life.
  3. At the cold end, join each thermocouple wire to a copper lead with a twisted, soldered joint. Put both joints together in a small glass tube standing in a jar of crushed ice and water — exactly 0 °C. This is the cold junction.
  4. Run the copper leads to the millivoltmeter.

Without ice: let the cold junction sit at room temperature, measure the room with an ordinary The Thermometer, and add the room temperature to your reading. It is accurate to a few degrees for iron–constantan.

4. Calibrate it

A home-made couple will not exactly match any table. Calibrate it against things whose temperatures are fixed by nature.

  1. Ice point: hot junction in crushed ice and water → 0 mV. (If not, check for a stray junction somewhere.)
  2. Boiling water: about 100 °C at sea level, about 1 °C less for every 300 m of altitude.
  3. Freezing points of pure metals. Melt 200–500 g of a pure metal in a small crucible, under a layer of charcoal powder to keep air off. Push the sheathed thermocouple deep into the melt. Turn off the heat and read every 15–30 seconds as it cools. The reading falls, then stops falling and holds steady for several minutes while the metal freezes — the heat given out by freezing holds the temperature still. That steady reading is the metal's freezing point.
Metal Freezes at
Tin 232 °C
Lead 327 °C
Zinc 420 °C
Antimony 631 °C
Aluminium 660 °C
Common salt (melted) 801 °C
Silver 962 °C
Gold 1,064 °C
  1. Plot the millivolts against the temperatures on squared paper and draw a smooth curve through the points. Read any later millivolt value off the curve, or make a table and paint it on a board beside the furnace.
Voltage against temperature millivolts, cold junction at 0 °C 0100200300400500600700800010203040 tin 232 °Clead 327 °Czinc 420 °Caluminium 660 °C iron–constantan about 5.3 mV per 100 °C copper–iron: turns over near 270 °C °C at the hot junction A freezing plateau pure zinc cooling in its crucible 420 reading holds still while it freezes: time, minutes liquid solid
Fig. 2 Calibrating a thermocouple. Left: the voltage of an iron–constantan couple rises almost in a straight line, about 5.3 mV per 100 °C, while copper–iron turns over near 270 °C and becomes useless. Right: a melt of pure metal cooling past its freezing point holds a flat plateau — a fixed temperature to calibrate against.

For comparison, a standard iron–constantan couple with its cold junction at 0 °C reads about: 5.3 mV at 100 °C, 10.8 at 200, 16.3 at 300, 21.8 at 400, 27.4 at 500, 33.1 at 600, 39.1 at 700. Yours should be within a few percent.

5. The meter

The voltage is small, so the meter matters.

  • Use a moving-coil meter reading 0–50 mV full scale for iron–constantan to 750 °C (Measuring Electricity).
  • Give the meter a resistance at least 100 times that of the thermocouple and its leads (a couple and leads might be 1–3 Ω; so the meter should be 200–300 Ω or more). Then the reading hardly changes when the wires heat up or you lengthen the leads.
  • Calibrate the couple and meter together, with the same leads, and never change one without recalibrating.
  • For the best accuracy, measure with a potentiometer — balance the thermocouple's voltage against a known, adjustable voltage until the galvanometer reads zero (Measuring Electricity). No current flows, so wire resistance does not matter at all.

Thermopiles

Join many couples in series, with all the odd junctions on the hot side and all the even ones on the cold side, and their voltages add: a thermopile.

A thermopile: many couples in series cold junctions, with fins (or a water jacket) hot junctions over the burner, kept below about 400 °C zinc–antimony alloy iron strip − +to theload to theload each pair adds about 0.05 V
Fig. 3 A thermopile. Bars of two different metals alternate, joined end to end in a zigzag, so that every other junction is in the heat and the rest are on the cool side. Each pair adds its small voltage.

As a heat detector. Twenty to fifty tiny bars of bismuth and antimony (or fine bismuth and antimony wires), their hot ends blackened with soot and set behind a polished metal cone, feeding a sensitive galvanometer. It detects the warmth of a hand at a metre and measures the heat in sunlight or in the invisible infrared beyond the red of a spectrum (The Spectroscope). Keep it shielded from draughts. Bismuth melts at 271 °C: never put it in a flame.

As a current source. A flame or a stove can drive a thermopile to give a steady, quiet current for a The Telegraph, a small Electroplating bath, or charging a battery, with no chemicals to replace.

  1. Elements: cast bars of a zinc–antimony alloy (about 35 parts zinc to 65 antimony by weight; melt the antimony under charcoal, then add the zinc), each about 10 cm long and 1 cm square. Join each bar's ends to strips of iron (or constantan) by casting the bar onto the strip.
  2. Arrange them in a ring round a gas or charcoal burner, hot junctions inward, cold junctions outward with thin copper or iron fins to shed heat (or dipped in a water jacket).
  3. Keep the hot side below about 400 °C — the alloy melts at about 550 °C, and runs better if not pushed.
  4. Expect roughly 0.05 V per pair with 300 °C between the hot and cold sides, so 40–60 pairs give 2–3 V.

Be honest about the cost: a metal thermopile turns less than 1% of the fuel's heat into electricity. It is worth it only where a steady, maintenance-free current matters more than fuel. Semiconductor materials do several times better (Semiconductors and the Transistor).

The flame-failure valve

A simple, life-saving use: a valve on a gas line (Biogas and Wood Gas) that is held open only while the flame is lit.

  1. Put a short, thick iron–constantan thermocouple, sheathed in a thin iron tube closed at the tip, in the edge of the pilot flame. It slowly burns away; replace it when the valve starts to drop out on its own.
  2. Connect it directly to a small electromagnet wound with a few turns of thick copper — its resistance must be tiny, a hundredth of an ohm or so, because the couple gives only 20–30 mV (The Electromagnet).
  3. The magnet is too weak to pull the valve open, but strong enough to hold a soft-iron plate on a spring-loaded valve once it is pushed against it. To light the burner, press a button that pushes the plate against the magnet and lets gas through; light the pilot; hold for 30–60 seconds while the couple heats; release.
  4. If the flame blows out, the couple cools within a minute, the magnet lets go, and the spring snaps the valve shut.

How to tell it worked

  • Zero at the ice point: both junctions in ice water reads 0 mV.
  • Steady and repeatable: the same furnace, the same heat, the same reading day after day; the freezing plateaus of tin, lead and zinc fall on a smooth curve.
  • Agrees with nature: a scrap of zinc, aluminium or salt on a tile beside the bead should melt just as the reading passes its melting point (The Thermometer lists these sentinels).
  • Responds quickly: lifting a sheathed couple out of a furnace makes the reading fall within seconds to a minute.

Note Troubleshooting. Reading goes backwards (needle below zero) → wires reversed at the meter; swap the leads. Reading drifts lower over weeks → the hot end is oxidising or the alloy is changing; cut off the end, re-bead, and recalibrate. Use a sheath. Reading jumps when you touch or move the leads → a loose joint, or one of the copper–thermocouple joints is warmer than the other; put both together in the cold bath. Reading too low compared with cones or colours → the bead is not at the hottest point, the sheath is too thick, or the meter's resistance is too low. Push it in farther; use a high-resistance meter. Reading stops rising above about 270 °C → you are using copper–iron; change to iron–constantan. No plateau when calibrating → the metal is impure (it freezes over a range), or too little metal; use a purer metal and at least 200 g.

Dangers

Danger Molten metal and furnaces. Calibrating means handling crucibles of molten tin, lead, zinc and aluminium. A damp tool or a wet crucible makes molten metal explode out. Dry and preheat everything; wear leather and a face shield. Lead and antimony fumes are poisonous and zinc fumes cause metal fume fever: melt outdoors, upwind, and do not overheat (Lead, Antimony and Bismuth, Zinc and Brass). Never melt metals in kitchen pots.

  • The fusing arc is bright enough to burn the eyes: look through dark glass (Welding).
  • A wrong reading can be dangerous: an over-fired kiln or a boiler thought to be cooler than it is. Check thermocouples against cones and sentinels from time to time (The Thermometer).
  • Gas valves must be tested: blow out the flame on purpose and check the valve closes within a minute before trusting it.

Going further

How it was first done

In 1821 the Estonian-German physicist Thomas Johann Seebeck, working in Berlin, found that a compass needle swung near a closed loop of bismuth and copper when he warmed one of the joints. He believed he had found a way that heat made magnetism; Hans Christian Ørsted soon showed that a current was flowing and named it thermoelectricity. The Italian Leopoldo Nobili built a thermopile around 1829, and Macedonio Melloni used it in the 1830s to show that radiant heat behaves like light. The French watchmaker and physicist Jean Peltier discovered the reverse heating and cooling effect in 1834, and in 1838 Emil Lenz froze a drop of water on a bismuth–antimony junction with it. William Thomson (later Lord Kelvin) worked out the theory linking the effects in the 1850s.

In 1886 Henri Le Chatelier in Paris introduced the platinum / platinum-rhodium thermocouple, and within a few years it was the standard way of measuring the heat of furnaces, kilns and steel. Gas-fired thermopiles by Charles Clamond (1870s) and Gülcher (1890) powered electroplating and telegraphs. In the 1950s the Soviet physicist Abram Ioffe led work on semiconductor thermoelectric materials that powered radios from kerosene lamps; similar generators heated by radioactive decay still power deep-space probes such as Voyager, launched in 1977.