Part 9 · Health and Medicine
Syringes and Hypodermic Needles
How to make syringes — from a rubber bulb to the all-glass syringe with a ground plunger — and hypodermic needles, by rolling, soldering and drawing steel or silver down to a tube finer than a pin, grinding the point and fitting the hub; and how to give injections safely, clean and sterilise every syringe and needle between patients, and never share a needle.
- Difficulty
- ●●●●●
- Time
- An hour for a bulb syringe; days to grind a glass syringe; weeks of practice before your needles are fine, straight and sharp
- Steps from zero
- 33 prerequisites →
This unlocks
—The full path from nothing — 33 steps before this one
- Fire
- Cordage and Rope
- Stone Tools
- Finding and Preparing Clay
- Finding and Identifying Ores
- Sanitation and Germs
- Hunting and Trapping
- Basic Woodworking
- Charcoal
- Pottery
- The Kiln
- Hides and Leather
- Bricks
- Lime
- Fermentation
- The Wheel and Axle
- Firebrick and Refractories
- Bellows
- Distillation
- Gears
- Iron (the Bloomery)
- Copper Smelting
- Sterilising Instruments and Dressings
- The Waterwheel
- Blacksmithing
- Magnets
- Sheet Metal and Rolling
- Copper Wire
- The Generator
- The Electric Arc Furnace
- Calcium Carbide and Acetylene
- Welding
- Metal Pipes and Tubes
- Syringes and Hypodermic Needles
Do them roughly in this order. See it on the tech tree →
Why it matters
A syringe and a hollow needle put a medicine exactly where it is needed, in exactly the right amount: Penicillin into a muscle when someone is too ill to swallow, a vaccine into the skin (Vaccination), a numbing drug before stitching (Anaesthesia, Basic Surgery), insulin under the skin, fluid into a vein (Intravenous Fluids). The same tools draw blood for tests and Blood Typing and Transfusion.
They are also among the most dangerous objects in medicine. A needle used on one person and then another without sterilising carries hepatitis B, hepatitis C and HIV between them. The World Health Organization estimated that in the year 2000 unsafe injections caused about 21 million hepatitis B, 2 million hepatitis C and a quarter of a million HIV infections. So this chapter has two halves, equally important: how to make syringes and needles, and how to use and clean them so they never pass disease on.
Note Most medicines work by mouth. Inject only when the patient cannot swallow or keep things down, when the stomach destroys the drug (insulin, some penicillins), when speed matters, or for vaccines. A clinic that cannot sterilise its needles does more good giving medicines by mouth.
How it works
The syringe is a small pump. A plunger slides in a barrel; pull it back and outside air pressure pushes liquid in through the nozzle, push it and the liquid goes out. The plunger must seal all along the barrel, or the syringe sucks air and pushes medicine backwards past the plunger. A barrel of even bore holds the same amount in every centimetre, so evenly spaced marks measure the dose.
The needle is a hollow tube cut at a slant. The slanted end — the bevel — slices into the skin rather than punching out a plug. Finer needles hurt and damage less; wider ones let thick liquids and blood flow faster.
The two join with a taper. The nozzle is a cone narrowing by 6 parts in 100 of its length (0.6 mm in every 10 mm) — the Luer taper. The needle's hub has a matching cone inside; pushed together with a slight twist, the cones grip and seal without a thread. Make every nozzle and hub to the same taper, so any needle fits any syringe.
Needle sizes are given by a gauge number: the bigger the number, the thinner the needle.
| Gauge | Outside diameter | Typical use | Typical length |
|---|---|---|---|
| 16 G | 1.65 mm | Blood donation, very fast drips | 4 cm |
| 18 G | 1.27 mm | Drawing up thick medicines; drips and transfusions | 4 cm |
| 21 G | 0.82 mm | Taking blood; injections into adult muscle | 2.5–4 cm |
| 23 G | 0.64 mm | Injections into children's muscle; small veins | 2.5 cm |
| 25 G | 0.51 mm | Under the skin; babies' muscle | 1.6–2.5 cm |
| 26–27 G | 0.46–0.41 mm | Into the skin (BCG vaccine, skin tests) | 1 cm |
If you can make only one size, make 21 G, 3 cm long: it serves for most muscle injections and blood samples.
What you need
| Item | For |
|---|---|
| Steel strip 0.2–0.3 mm thick, or silver sheet (Sheet Metal and Rolling, Gold and Silver) | Needle tube |
| Hard steel wire in several sizes; a draw plate with holes down to 0.5 mm (Iron and Brass Wire) | Mandrels, stylets, drawing tube |
| Silver solder, pure tin, borax (Soldering and Brazing); brass rod and a The Lathe | Seams and hubs |
| Heavy-walled glass tube and glass rod (Laboratory Glassware); emery, coarse to finest (Abrasives and Grinding Stones) | Barrels and plungers |
| Fine oilstones and a leather strop | Sharpening points |
| Natural rubber (Rubber) | Bulbs, plunger seals, stoppers |
| A lens (Lenses), a balance (Measurement from Scratch), an autoclave (Sterilising Instruments and Dressings) | Inspecting, calibrating, sterilising |
Method 1: The bulb syringe
The simplest syringe is a squeeze bulb on a nozzle. It cannot measure or inject, but it washes wounds (Wound Care and Antiseptics), flushes ears, and sucks mucus from a newborn's nose and mouth (Safe Childbirth).
- Bulb: dip a pear-shaped former of fired clay or plaster in latex or rubber solution 8–12 times, to a wall about 2 mm thick (Rubber); cure, then break out the former. 60–100 ml for wound washing; 15–30 ml for a baby's nose.
- Nozzle: a glass or smooth bone tube, rounded at the tip, bound tightly into the neck.
- Without rubber: an animal bladder tied onto a goose quill does the same job.
A good bulb springs back at once and draws water in a full gulp; sticky or cracked bulbs are spent. Boil them — dry heat ruins rubber.
Method 2: The metal syringe
The first hypodermic syringes were small tubes of silver or brass with a packed plunger.
- Barrel. Brass or silver tube (Metal Pipes and Tubes) 6–7 cm long, lapped smooth inside: a rod coated with fine emery in oil is turned and worked back and forth along the whole bore until it is even.
- Ends. Screw-on brass caps: the front one carries the nozzle, turned to the Luer taper; the back one guides the plunger rod.
- Plunger. A brass rod ending in a disc of thick rubber or two leather cups (Packing, Gaskets and Seals) clamped between washers by a nut; tightening the nut spreads the packing to seal.
- Better: a glass barrel held between the metal ends, so you can see the dose and bubbles — the Record pattern, used everywhere for most of the 1900s.
Metal syringes do not break, but blood dries in their joints; they must be taken fully apart to clean. Rubber packings stand heat better than leather.
Method 3: The all-glass syringe
Glass barrel, glass plunger, no packing: it seals only because the plunger is ground to fit its own barrel so closely that a film of liquid in the gap is the seal. It is the best reusable syringe — easy to see through and clean, unharmed by steam or dry heat.
- Barrel blank. Heavy-walled glass tube (wall 1.5–2 mm) of nearly the right bore, the straightest and most even in a batch (Laboratory Glassware). Cut to length and anneal (Glass).
- Nozzle end. Heat one end and work it into a short, thick cone with a bore of about 1.5 mm.
- Grind the bore. Make a lap — a rod of cast iron, brass or hardwood a little narrower than the bore — coat it with emery and water, and turn it slowly while you slide the barrel back and forth along it. Work through three or four grades, finest last, until the bore is evenly frosted with no shiny spots (low places the lap has missed).
- Grind the plunger. A glass rod a little bigger than the bore is ground round — rolled under a flat iron plate with emery, or turned against a stone in a The Lathe — until it just starts to enter.
- Lap them together. Put the finest emery and water on the plunger and work it in and out of the barrel with a twisting motion, many hundreds of times, until it slides the whole length smoothly. Wash thoroughly. From now on the two are a pair. Scratch the same number on barrel and plunger; a plunger in the wrong barrel will leak or seize.
- Grind the nozzle. Turn a hardened steel taper gauge — a female cone with the 6 % taper — and grind the glass nozzle into it with fine emery until it seats evenly along its whole length. Use the matching male gauge to ream the needle hubs, so all fit.
- Graduate. Stand the syringe nozzle-down, sealed with a finger, and weigh water into it in steps of 0.1 ml (0.1 g) for a 1 ml syringe, 0.2 ml for 2 ml, 0.5 ml for 5–10 ml (Laboratory Glassware, Measuring vessels). Mark each level and cut the lines with a corundum point. Rub dark paint into the lines.
| Syringe | Bore | Length of the scale | Marked every | Main use |
|---|---|---|---|---|
| 1 ml | 4.7 mm | 5.8 cm | 0.01–0.02 ml | Vaccines, insulin, babies' doses |
| 2 ml | 6.2 mm | 6.7 cm | 0.1 ml | Most injections |
| 5 ml | 12 mm | 4.4 cm | 0.2 ml | Larger doses, local anaesthetic |
| 10 ml | 14.5 mm | 6 cm | 0.5 ml | Blood samples, washing |
| 20 ml | 19 mm | 7 cm | 1 ml | Washing wounds, aspirating |
Tip A glass syringe whose plunger sticks after drying is not ruined. Soak it in warm water for an hour, or warm the barrel gently in water; the glass barrel expands slightly more than the cold plunger and lets go. Never force it — it shatters in your hand.
Method 4: Hypodermic needles
The needle is the hardest part. You are making a tube about 0.8 mm across with a hole of 0.5 mm, straight, sealed all along its length, with a point sharper than a sewing needle. Make them in batches and treat each one as precious.
1. A starting tube
- Strip. Roll and anneal steel strip 0.25 mm thick and about 8 mm wide (Sheet Metal and Rolling, Steel). Low-carbon iron or mild steel draws most easily; a little more carbon gives a stiffer needle. Silver draws even more easily and never rusts, but makes a soft needle that bends; use it for under-the-skin needles if steel defeats you.
- Curl. Lay a hard steel wire 2.4 mm across along the strip and draw both together through a series of shaped holes in a hard block — first a U-shaped groove, then rounder and smaller holes — until the strip wraps the wire with its edges meeting.
- Seal the seam. Feed borax and a thin thread of silver solder along the seam, and run a small hot flame slowly along it so the solder flows into the joint (Soldering and Brazing). Or braze with copper under charcoal; or, with electric welding, fuse the seam (Welding). The whole value of the needle depends on this seam being closed along every millimetre.
- Clean off the flux in hot water and pickle in weak acid (Acids, Bases and Testing).
2. Drawing it fine
- Point the end of a length about 30–50 cm long so it enters the first hole of the draw plate (Iron and Brass Wire). Lubricate with soap or tallow.
- Draw on the mandrel for the first passes: leave the wire inside, so the hole squeezes the wall thinner against it. Then roll the tube firmly between two flat boards to loosen it, and pull the wire out.
- Sink the tube the rest of the way — through smaller and smaller holes with nothing inside. Each pass should reduce the diameter by only about one-tenth. Anneal after every two or three passes at a dull cherry red (about 700 °C) in a closed pot with charcoal, and pickle off the scale (Metal Pipes and Tubes).
- The last two passes are not annealed. Drawing makes the metal harder and springier ("work-hardening"), and that stiffness is what you want in a finished needle.
- Keep the bore open. Push a fine wire (stylet) through every so often and blow water through; a tube that has drawn shut is lost.
From 3 mm down to 0.82 mm takes about 12–15 passes.
3. Point and hub
- Cut lengths 8 mm longer than the finished needle (the extra goes into the hub). Score round with the edge of a fine file and snap; ream the ends with a fine broach.
- Grind the main bevel. Make a jig: a hard block with a fine groove cut across its face at 12° to the surface (about 1 in 5). Lay the needle in the groove so its end projects slightly, and stroke it along a fine, flat oilstone until the slanted face is about 4–5 times as long as the needle is wide (3.5–4 mm on a 21 G).
- Grind the side facets. Roll the needle 15–20° one way in the groove and give the tip a few light strokes, then the same the other way. These two small facets make the sharp lancet point that cuts a tiny curved slit instead of punching a hole. For needles into veins and into the skin, grind a short bevel — about 18°, about two-thirds as long — so the whole opening fits inside a small vein.
- Hone and deburr. Finish on the finest stone and a leather strop. Push a stylet through from the hub end to knock off any burr inside, and draw the point lightly through a cork.
- Hub. Turn a brass hub about 10 mm long, with the female Luer cone inside (reamed with your male gauge) and a fine hole at the bottom that fits the needle closely. Push the needle 6–8 mm into the hub and solder it with pure tin (melts at 232 °C) or silver solder. Never use lead-tin solder — it softens near the temperatures of dry-heat sterilising and puts lead into the patient. Give the hub two small flat wings or a square flange so you can grip it.
- Stylet. For each needle, keep a fine wire that fills its bore, to put in for storage and sterilising so the bore cannot block with dried matter.
How to tell it worked
The syringe:
- Suction test. Close the nozzle with a fingertip, pull the plunger back to the three-quarter mark and let go. A good syringe springs back to near zero; if it creeps back slowly, air is leaking past the plunger.
- Pressure test. Fill with water, close the nozzle, push hard: no water comes past the plunger.
- Accuracy. 1 ml expelled onto the balance weighs 1.0 g within about 2 %.
The needle:
- Look through it at a bright window: you should see a round spot of light.
- Jet test. Push water through: it should come out in a single straight thin jet. A spray from the side means a crack or an open seam — destroy that needle.
- Point test. Under the lens, the point is sharp, with no hook, flat spot or curl. Drag the tip lightly across a wisp of cotton wool: a good point slides through; a hooked point snags and pulls fibres. A hooked needle tears skin and veins.
- Feel test. Stretch thin rubber sheet or fine leather over a cup. A sharp needle goes through with almost no push; a blunt one dents it deeply, then pops through.
- Hub test. Twist and pull the needle with cloth-wrapped pliers: it must not move in the hub.
Note Troubleshooting. Tube splits during drawing → too much reduction per pass, or not annealed often enough. Tube draws shut → pass the stylet more often; draw on a mandrel for longer. Needle bends at the hub → the metal there was softened by soldering heat; use tin solder with a smaller flame, or support the joint with a longer hub. Point curls over on the first use → the bevel is too long and thin or the steel too soft; grind a slightly shorter bevel. Syringe leaks after sterilising → plunger and barrel mixed up; check the numbers. Rust inside needles → dry completely after cleaning and store with the stylet in.
Safe injection practice
Anyone who gives injections should first practise under supervision on many patients. These rules are not negotiable.
One sterile needle and one sterile syringe for every injection. Not the same syringe with a fresh needle; not a quick rinse in a pot of water between people. Blood flows back into syringes, unseen.
- Before: is an injection really needed? Check the medicine, dose, date and clarity; the patient's name and any allergy (especially to penicillin). Wash your hands (Sanitation and Germs). Take a set from the sterile store and check the pack is dry and sealed.
- Drawing up: wipe the bottle's rubber stopper with alcohol and let it dry. Draw air to the dose, push the needle through the stopper, inject the air, turn the bottle up and draw the dose. Push out bubbles; check the dose at eye level. Never leave a needle in the stopper, and never go back into a bottle with a used needle.
Where and how:
| Route | Angle | Where | Most at once |
|---|---|---|---|
| Into the skin (intradermal) | Almost flat, 10–15°, bevel up | Inside forearm; upper arm for BCG | 0.1 ml; a small pale bump rises |
| Under the skin (subcutaneous) | 45°, skin pinched up | Back of upper arm, belly, front of thigh | 1–2 ml |
| Into muscle (intramuscular) | 90°, skin stretched flat | Outer middle of the thigh (babies and children); the shoulder muscle, three finger-widths below its bony tip (adults, up to 1 ml); the side of the hip | 1 ml in the shoulder; 3–5 ml in thigh or hip of an adult |
| Into a vein | 15–25°, bevel up | See Intravenous Fluids | — |
Warning The buttock hides the sciatic nerve, the thickest nerve in the body. Injections into the middle or lower buttock have paralysed many children's legs. Use the outer thigh in children. In adults, if you use the hip, put the heel of your hand on the bony knob at the side of the top of the thigh, your index finger on the bony point at the front of the hip, and spread your middle finger back along the hip bone; inject in the "V" between the two fingers — well away from the nerve.
Clean the skin and let it dry. Insert the needle quickly, inject slowly (about 10 seconds per ml into muscle), pull out, and press with a dry swab. Watch the patient for 15–30 minutes after any injection of penicillin or a vaccine — severe allergic reactions come within minutes (Emergencies).
After:
- Never put the cap back on a used needle with two hands — that is how most needle-stick injuries happen. Drop it straight into the sharps box.
- Needle-stick injury: let it bleed, wash with soap and running water, do not suck or squeeze hard; write down whose blood it was. Tell someone.
The sharps box
Every place injections are given needs one, within arm's reach. Make it from a thick tin can, a section of bamboo, or a strong glazed pot with a lid that has a slot just wide enough to drop a needle through and too narrow for fingers (Tins, Cans, Drums and Tanks, Pottery). Mark it clearly. Close it when three-quarters full.
- Disposable needles: burn the closed box in a hot fire or furnace, then bury the remains in a pit fenced from children and animals.
- Reusable needles go into a box half filled with cold water, so blood does not dry inside them, and are carried to the cleaning room.
Cleaning and sterilising reusable sets
- At once, before blood dries, draw cold water through syringe and needle several times.
- Take the syringe apart, keeping pairs together. Wash in warm soapy water with a brush; push the stylet through each needle; rinse three times, last in boiled or distilled water.
- Inspect every needle under the lens and test each syringe. Re-sharpen or discard.
- Pack each set — one syringe, one or two needles with stylets in — in a closed metal tray or a double cloth wrap.
- Sterilise: by steam at 121 °C for 30 minutes wrapped, or dry heat at 170 °C for 1 hour (all-glass syringes and needles; not rubber). Boiling for 20 minutes in a covered pot is the last resort: it kills most germs but not all, and the set must be used within the day (Sterilising Instruments and Dressings).
- Count sets out and sets back. If you do not have enough sterile sets for the people waiting, stop — do not make one do for two.
Dangers
Danger Never share a needle or a syringe — not with family, not with a friend, not "just once". This applies to medicine, to drugs, to tattooing, to piercing and to traditional scarring alike. Hepatitis B, hepatitis C and HIV pass on unseen in a trace of blood and may show no sign for years. One person, one sterile needle and syringe, one time.
- Needle-stick injuries spread the same diseases to the person giving injections.
- Abscesses come from dirty skin, unsterile sets or contaminated bottles; a hot, painful swelling days later needs draining (Basic Surgery).
- Nerve injury — the sciatic nerve in the buttock; the radial nerve if you inject too low in the upper arm.
- Wrong dose. A misread mark can give ten times the dose. Read at eye level; have a second person check strong drugs.
- Allergic reactions can kill within minutes (Emergencies).
What this unlocks
Vaccination, Penicillin and Insulin (Overview) given properly; local anaesthesia for Dentistry; blood for tests and Blood Typing and Transfusion. Later: stainless steel needles that never rust (Alloy and Stainless Steels); disposable plastic syringes (Early Plastics), and auto-disable syringes whose plunger locks after one use. The rest of the clinic's tools are in Medical Instruments and Stretchers, Hospital Beds and Patient Equipment.
How it was first done
In 1656 Christopher Wren in Oxford injected substances into dogs' veins through a sharpened goose quill tied to an animal bladder. In 1844 Francis Rynd in Dublin let morphine run into a patient's tissue through a hollow needle. In 1853, independently, Charles Pravaz in Lyon made a small silver syringe with a screw-driven plunger, and Alexander Wood in Edinburgh used a glass syringe with a fine hollow needle to inject morphine near painful nerves — the first true hypodermic syringe in general use.
In the 1890s the Paris instrument maker Hermann Wülfing Luer sold an all-glass syringe, and the tapered nozzle still bears his name; the Record syringe of glass and metal followed in 1906, and a screw-locking version of the Luer fitting in 1925. Plastic disposable syringes came in the 1950s — among the first was one by Colin Murdoch in New Zealand in 1956 — and spread worldwide by the 1970s, with the hard lesson that disposables, too, get reused.
Source: content/entries/health/syringes-and-needles.md