◆ Rebuild

Part 6 · Building

Hot Water and Central Heating

How one fire can heat a whole house and its bathwater — the back boiler behind a range, the hot water cylinder, the wood-chip and gas geyser, radiators and the pipes between them, circulating by themselves because hot water rises — and the open vent, expansion tank and safety valves that stop it all from bursting, boiling or freezing.

Difficulty
●●●●●
Time
A week to fit a back boiler and cylinder; a month or two to pipe a house for heating
Steps from zero
33 prerequisites →

You need first

Pipes, Plumbing and AqueductsBoilers and Pressure VesselsChimneys, Stoves and Heating

This unlocks

Heat Pumps and District Heating
The full path from nothing — 33 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Measurement from Scratch
  7. Writing and Numbers
  8. Hunting and Trapping
  9. Basic Woodworking
  10. Pottery
  11. The Kiln
  12. Charcoal
  13. Arithmetic and Fractions
  14. Hides and Leather
  15. Tiles and Clay Pipes
  16. Bricks
  17. Surveying and Levelling
  18. The Wheel and Axle
  19. Firebrick and Refractories
  20. Bellows
  21. The Lathe
  22. Gears
  23. Lead
  24. Iron (the Bloomery)
  25. Copper Smelting
  26. The Waterwheel
  27. Blacksmithing
  28. The Blast Furnace and Cast Iron
  29. Pipes, Plumbing and Aqueducts
  30. Sheet Metal and Rolling
  31. Chimneys, Stoves and Heating
  32. The Steam Engine
  33. Boilers and Pressure Vessels
  34. Hot Water and Central Heating

Do them roughly in this order. See it on the tech tree →

Why it matters

A fire in one room heats one room (Chimneys, Stoves and Heating), and every bath means carrying and heating water by the bucket. Put a small water tank behind the fire and run pipes from it, and the same fire — already burning for cooking — fills a tank with hot water for washing and warms rooms through the walls of the house. Central heating is just this idea made larger: one well-built fire or boiler, in one safe place, heating every room through pipes, instead of many smoky fires in many rooms.

Hot water in the tap makes washing hands, bodies, clothes and dishes easy, which prevents disease (Personal Hygiene, Toilets, Sinks, Baths and Showers). Central heating saves fuel, keeps the old and sick alive through winter, and keeps houses dry, so that walls and timbers do not rot.

How it works

Hot water rises. Water at 80 °C is about 3% lighter than water at 10 °C. Join a heater at the bottom to a tank above it by two pipes and water circulates by itself: heated water rises up the flow pipe, and cooler water sinks back down the return. This is the thermosiphon (gravity circulation) that also drives the solar heater in Solar Heat.

The push is weak. With flow at 80 °C, return at 60 °C and the tank 3 m above the boiler, the difference in weight between the two columns is only about 3–4 cm of water. So gravity systems need:

  • Wide pipes: 28–35 mm bore for a cylinder circuit, 35–50 mm for the main of a heating system.
  • Few bends, and every pipe rising steadily from boiler to tank, never dipping (a dip traps air, and an air bubble stops gravity circulation dead).
  • Height: the cylinder and radiators above the boiler. More height gives more push.

A pump (Centrifugal Pumps and Fans) driving the water round lets the pipes shrink to 15–22 mm, the boiler sit anywhere, and the heat reach far rooms quickly — but it needs power and fails if the power fails.

How much heat water carries. One litre warmed 1 °C takes 4.2 kJ. Water flowing at 3 litres a minute and cooling by 20 °C in the radiators delivers about 4 kW — enough for two or three rooms.

Water expands when heated. From cold to 80 °C, it grows by about 3%; to boiling, over 4%. A 150-litre system grows by 5 litres. That water must go somewhere, or the pressure rises until something bursts. And if the water ever boils in a closed vessel, the steam can blow it apart like a bomb (Boilers and Pressure Vessels). Everything in the safety section below follows from these two facts.

ROOF SPACEUPSTAIRSKITCHEN Open vent never valved Feed and expansion tank 10 cm of water when cold; room to rise Cold feed to the return flow rises hot to taps cold in Cylinder indirect: boiler water heats a coil Radiator under the window return falls back to the boiler Back boiler behind the range fire
Fig. 1 A gravity hot-water and heating system. The back boiler behind the kitchen fire sends hot water up the flow pipe to the coil in the cylinder and to a radiator; cooler water sinks back down the return. The small tank in the roof keeps the system full and gives the water room to expand; the open vent above it can never be shut, so the system can never build up pressure.

What you need

Item For See
Copper sheet 1–3 mm, or iron plate 5–6 mm Back boilers, cylinders, geysers Copper Smelting, Sheet Metal and Rolling, Iron (the Bloomery)
Copper, iron or steel pipe 15–50 mm, fittings Flow, return, vent, feed Metal Pipes and Tubes, Pipes, Plumbing and Aqueducts
Cast iron and sand moulds Radiators, boilers The Blast Furnace and Cast Iron, Metal Casting
Brazing and soldering Joints in copper Soldering and Brazing
Taps and dies Pipe threads Screws, Nuts and Bolts
Firebrick and fireclay Fireboxes Firebrick and Refractories
Wool felt, straw rope, cork, sawdust Lagging Insulation and Keeping Buildings Warm or Cool
Brass valves, a pressure gauge, a thermometer Control and safety Pressure and Vacuum Gauges, The Thermometer

Where to find it: the metals and refractories are covered in their own chapters. Use soft water — rainwater (Wells and Cisterns) — in any closed heating circuit if you can: hard water leaves stony scale in the hottest part of the boiler (Boilers and Pressure Vessels).

The heat sources

Back boiler

A water tank built into the back or side of a fireplace, kitchen range (Cooking Ranges, Iceboxes and Vacuum Flasks) or stove, so the fire that cooks also heats water.

  1. Shape: a flat box or an "L" or horseshoe wrapping the back of the firebox, about 30–45 cm wide, 25–35 cm high, 10–15 cm deep, holding 8–20 litres. Bigger surface touching the fire gives more heat; a box with a flue passing through it (a "boot" boiler) gives more still.
  2. Material: copper 2–3 mm, brazed or riveted and soldered — conducts heat well and does not rust; or wrought iron or steel 5–6 mm, riveted or forge-welded (Boilers and Pressure Vessels); or cast iron for ranges built in a foundry. Never use soft solder where the fire touches.
  3. Connections: two 28–35 mm pipe sockets: the flow from the top of the boiler, the return into the bottom — never the other way round. Add a drain cock at the lowest point.
  4. Test it with water at twice the highest pressure it could ever see — for a gravity system with the roof tank 8 m up, that is 0.8 bar, so test to at least 2 bar (Boilers and Pressure Vessels).
  5. Build it in to the back of the firebox with firebrick round it, the face toward the fire, leaving the fire room to burn hot. A damper can send the flames past the boiler or away from it.

A range boiler gives 2–5 kW of heat to the water while the fire burns well. A 140-litre cylinder needs about 8 kWh to heat from 10 °C to 60 °C, so a good cooking fire heats it in 3–4 hours.

Danger Never light a fire under an empty or frozen back boiler. If the pipes are frozen solid or a valve is shut, the boiler cannot expand or vent; the water inside turns to steam and the boiler explodes, throwing the range across the kitchen. Kitchen-range boilers killed many people this way in 19th-century winters. If the pipes might be frozen, let the fire stay out until they have thawed and water runs from the hot tap.

Hot water cylinder

The store between the boiler and the taps: an insulated upright tank, so hot water made slowly by the fire is there when you want a lot of it at once.

Size: 100–150 litres for a household — a common size is 45 cm across and 90–105 cm tall (about 115–140 L). Taller and narrower is better: hot water floats in a layer on top of the cold (stratification), so a tall tank gives hot water at the tap long before all of it is heated.

Making a copper cylinder:

  1. Roll a sheet of copper 1–1.5 mm thick into a tube and braze or rivet-and-solder the seam; for a cylinder under more than 1 bar (a roof tank more than 10 m above it), use thicker sheet.
  2. Domed ends, beaten into shape over a wooden form (Sheet Metal and Rolling); domes are far stronger than flat ends. Rivet and braze them in.
  3. Bosses (threaded fittings) brazed in: cold feed near the bottom; hot draw-off and open vent at the very top; boiler flow about a third of the way down; boiler return near the bottom; a drain cock at the bottom.
  4. Test with water to twice its working pressure.
  5. Lag it: 50–80 mm of wool felt, cork or straw rope held with string and wrapped in cloth, or a wooden box packed with sawdust (Insulation and Keeping Buildings Warm or Cool). An unlagged cylinder loses a third of its heat by morning.

Direct or indirect. In a direct cylinder the boiler heats the very water you draw. Simple, but every new fill of fresh water brings new scale into the boiler and corrosion into iron parts. An indirect cylinder carries a coil or inner tank of copper: the boiler water circulates round the coil and back, sealed in its own circuit, and heats the tap water through the copper wall. The boiler circuit's water is never changed, so it never scales and never rusts. Use indirect wherever water is hard or the boiler is iron.

A galvanised iron tank can stand in for copper, but rusts through in some years; a glass-lined steel tank (Enamel on Metal) lasts well.

Good: after a night the top of the cylinder is still too hot to keep your hand on through the lagging; the first tap at the far basin runs hot within a minute.

Water heater

A water heater heats water on its own, without a cooking fire. A storage water heater is a cylinder with its own small firebox or burner under it — the cylinder above, built exactly as above. An instantaneous heater, or geyser, heats the water as it flows through, so there is no store to keep hot.

WOOD-CHIP BATH HEATER GAS GEYSER Tap on the cold inlet Water jacket 10–20 litres Flue up the middle Open spout no tap, so it can never build pressure Firebox chips, twigs, paper Diaphragm: flowing water opens the gas Gas valve Pilot and flame- failure valve Copper coil Flue to outside hot out cold gas
Fig. 2 Left: a wood-chip bath heater. The fire heats a water jacket round the flue; cold water enters at the bottom through the tap, and hot water leaves by an open spout, so the heater can never hold pressure. Right: a gas geyser. Water flowing through pushes a diaphragm that opens the gas valve, so gas can burn only while water is flowing to carry the heat away.

Chip heater

The wood-chip bath heater (in Australia a "chip heater", in New Zealand a "califont"): a cheap, safe way to fill a bath with hot water from a handful of wood shavings, twigs or paper.

  1. Body: a copper or galvanised iron cylinder 25–35 cm across and 1–1.2 m tall, with a smaller tube (the flue) 10–15 cm across running up its middle. The space between is the water jacket, 10–20 litres.
  2. Firebox at the bottom: a small door, a grate, and an ash pan, lined with firebrick or thick iron. The flue continues up through the roof (Chimneys, Stoves and Heating).
  3. Plumbing — the rule that makes it safe: the tap goes on the cold inlet, at the bottom. The hot outlet at the top is an open spout that swings over the bath and has no tap. Water can always escape freely, so the jacket can never build pressure, however hot the fire. Never fit a valve on the outlet.
  4. Use: light a fire of chips or twigs and, once it roars, open the cold tap gently. The slower the flow, the hotter the water. About 2–3 kg of dry wood heats a 100-litre bath by 35–40 °C.

Geyser

The gas geyser heats water instantly as it passes over a burner, using coal gas, natural gas or biogas (Lanterns, Gas Lamps and Lighters, Natural Gas and Helium, Biogas and Wood Gas).

  1. Heat exchanger: a copper coil or finned copper tube over a row of gas burners, inside a sheet-metal case with a flue to the outside. Heating 6 litres a minute by 40 °C takes about 17 kW — a lot of gas, so the gas pipe must be large.
  2. The water valve — the heart of it. Water entering the heater passes a diaphragm (a disc of leather, later rubber) across a narrow throat. When water flows, the pressure difference pushes the diaphragm, and a rod on it opens the gas valve. When the water stops, a spring shuts the gas. So gas can burn only while water is flowing to carry the heat away.
  3. Pilot light: a tiny permanent flame that lights the burners when the gas opens. Fit a flame-failure valve — a bimetal strip or a sealed bulb of liquid, heated by the pilot, that holds the main gas valve open only while the pilot is alight (Thermostats and Automatic Control).
  4. Flue and air: every gas water heater needs a flue to the outside and a fresh-air inlet to the room. An unflued geyser in a small bathroom has killed many people with carbon monoxide.

Good: hot water within ten seconds of opening the tap; the flame goes out the instant the tap is shut; a clean blue flame with no yellow tips or soot.

Heating the rooms

Radiator

A surface that gives the water's heat to a room — about half by warming the air that flows over it, half by radiating to people and walls.

How much: a room needs roughly 50–100 W per square metre of floor in a cold winter, depending on walls, windows and insulation (Insulation and Keeping Buildings Warm or Cool). A cast-iron radiator gives about 450–500 W per square metre of its surface with water at 75–80 °C in a room at 20 °C. A bare iron pipe 50 mm across gives about 100–130 W per metre.

CAST-IRON COLUMN RADIATOR SEALED SYSTEM: EXPANSION VESSEL Flow valve Air bleed at the top Return valve set once, to balance Nipple R and L threads Sections hollow cast iron, 60–90 cm tall, walls about 4 mm; a nipple threaded right-hand one end and left-hand the other draws two sections together as it turns hot in at the top out at the bottom, far side Air valve to charge Air cushion ≈ 1 bar Rubber diaphragm water grows in Gauge Safety valve set 2.5–3 bar; outlet piped down where it can be seen to the heating circuit
Fig. 3 Left: a cast-iron column radiator. Hollow sections are drawn together by nipples threaded right-handed at one end and left-handed at the other; hot water enters at the top and leaves at the bottom on the far side, and air is bled from the top. Right: a sealed system's expansion vessel. As the water warms and grows it pushes the rubber diaphragm up and squeezes the air cushion; a safety valve and gauge sit on the same pipe.

Three ways to make one, simplest first:

  1. Pipe coil. Two to four runs of 35–50 mm iron pipe along the wall at skirting height, joined at the ends by return bends, on iron brackets. This is how glasshouses (Cold Frames, Cloches and Greenhouses) and churches were heated. Ugly but cheap and almost indestructible.
  2. Column radiator. Cast-iron sections, each a hollow loop with one or more upright tubes (columns), about 60–90 cm tall and 6–7 cm thick, joined side by side. Cast each section in green sand with a dry-sand core for the inside (Metal Casting); walls about 4 mm. Each section has a port at top and bottom on each side. Join the sections with short nipples threaded right-hand at one end and left-hand at the other: turned with a long bar reaching through the ports, one nipple draws two sections together. Seal each joint with a paper or leather washer and linseed paste.
  3. Pressed or folded sheet: two sheets of steel pressed into channels and seam-welded, or folded copper sheet soldered round tubes — light, cheap, quick to warm, but needs Welding or a press.

Fitting:

  • Put radiators under windows: they warm the cold air falling off the glass before it reaches the floor, so the room has no cold draught.
  • Flow in at the top on one side, return out at the bottom on the other side ("top-bottom-opposite"), so water passes through the whole radiator.
  • A valve on the flow to turn each one down, and a second, preset valve on the return to balance the system — throttle the near radiators so the far ones get their share.
  • An air bleed screw at the top of every radiator. Air collects there and stops it heating at the top. Open the screw with the system cool until water spits out, then shut it.
  • Paint it a thin coat of flat paint. Lagged covers and boxes cut the output.

Good: hot all over, top and bottom, within an hour of lighting the fire; the far radiator nearly as warm as the near one.

Pipework

  • One-pipe systems (gravity): a single wide main loops round the house; each radiator takes water from it and returns it a little further on. Simple, but the last radiators get cooler water.
  • Two-pipe systems: separate flow and return mains, every radiator getting water at the same heat. Better, and the standard with a pump.
  • Rise and fall. Mains rise steadily from the boiler (at least 1 in 100) to an air vent at every high point, and fall back to the boiler with a drain cock at every low point.
  • Lag every pipe that runs through a cold loft, cellar or outside wall — with wool, felt or straw rope bound with string and tarred cloth (Insulation and Keeping Buildings Warm or Cool).
  • Join copper by brazing or soldered sleeves, iron by screwed threads sealed with hemp and linseed paste (Pipes, Plumbing and Aqueducts); leave room for long pipes to grow — about 1 mm per metre of copper from cold to 80 °C — with a gentle offset or loop, not a straight pipe between two fixed walls.

Keeping it safe

Expansion tank

Every system needs somewhere for the extra water to go when it warms, and air to be let out.

Open (vented) system — the safest, needing no valves at all:

  1. A small feed and expansion tank — 20–45 litres, of copper, lead-lined wood or galvanised iron, with a lid — in the roof space, higher than every radiator and pipe.
  2. A float valve (Pipes, Plumbing and Aqueducts) keeps a little water in it — just 10 cm deep when cold, so it has room to rise as the system heats. An overflow runs outside.
  3. A cold feed pipe (at least 15 mm) runs from the bottom of this tank down to the return near the boiler.
  4. An open vent pipe (at least 22 mm) rises from the top of the boiler flow — or the top of the cylinder — and turns down over the tank, open to the air.
  5. No valve, ever, on the open vent or the cold feed. With them open, the system cannot build pressure higher than the height of the tank: if the fire overheats it, the water pushes up the vent and spills back into the tank.

Separate tanks serve the heating circuit and the cylinder's tap water in an indirect system: the heating water stays in its own small tank and is never renewed.

Sealed (closed) system: when there is no room for a high tank, or when using a pump at higher pressure. Instead of a tank, a closed expansion vessel — a steel or copper drum with an air cushion separated from the water by a rubber diaphragm (Rubber) — takes up the growth of the water by squeezing the air. Charge the air side to about the pressure of the cold system (often 1 bar). Size the vessel to at least a tenth of the system's water. A sealed system must have a safety valve.

Safety valve

  • On any sealed system, and on a vented back boiler as a second line of defence, fit a spring-loaded safety valve (Boilers and Pressure Vessels, Springs) close to the boiler, with no valve between them, set at about 2.5–3 bar, its outlet piped down to where a discharge will be seen but cannot scald anyone.
  • On a sealed hot water cylinder, add a temperature relief: a valve held shut by a sealed bulb or a wax capsule that opens at about 90–95 °C and dumps hot water, so the water can never reach boiling.
  • Test each by lifting its lever every few months: water should spurt and stop cleanly.

Frost

Water expands by a tenth when it freezes, enough to split any pipe or boiler.

  • Run pipes inside the warm part of the house, never in outside walls or under eaves; lag the rest.
  • Fit a drain cock at the lowest point of every circuit. When the house will stand cold, drain everything — boiler, cylinder, pipes, radiators — and open the top vents so air can enter.
  • In bitter cold, keep a small fire in overnight, or let a tap trickle.
  • A frozen system must thaw slowly — warm cloths, never a flame on a lead or soldered joint — and never with the fire under the boiler (see the danger above).

How to tell it worked

  • Within an hour of lighting, the flow pipe near the boiler is too hot to hold and the return is warm; you can feel the heat climbing the flow pipe toward the cylinder.
  • The cylinder's top is hot and its bottom cooler, and hot water runs at the far tap.
  • Every radiator is hot at the top and bottom.
  • No water in the expansion tank's overflow; the tank level rises a few centimetres as the system heats and falls back as it cools.
  • No knocking or gurgling; no steam from the vent pipe (a hiss of steam means the system is boiling — let the fire die down at once).

Note Troubleshooting. Cylinder stays cold, boiler pipes very hot → no circulation: an air lock in a high spot or a dip, a pipe too small, or flow and return swapped. Bleed the high points; re-lay the pipe rising steadily. Radiator cold at the top → air. Bleed it. Cold at the bottom → sludge; drain and flush the system. Far radiators cold → system not balanced. Close the return valves on the near radiators part-way. Banging and kettle-like rumbling in the boiler → scale, or the system near boiling. Soften the water or go indirect; let the fire down. Expansion tank overflows when hot → cold level too high. Lower the float valve. Water drips from the safety valve → system overpressure (expansion vessel lost its air: re-pump it) or dirt on the valve seat (lift it a few times). Hot water at the tap is dirty brown → rust from an iron tank or boiler. Go indirect, or replace with copper.

Dangers

Danger A closed vessel of hot water is a bomb. A back boiler, cylinder or heater with no open vent and no working safety valve — because the vent was valved off, frozen solid, or blocked with scale — will explode as soon as the water passes 100 °C. Never put a valve on the open vent or cold feed; never light a fire under a frozen or empty boiler; test every safety valve.

Danger Scalds. Water at 60 °C burns an adult's skin through in about 5 seconds, a child's faster; at 50 °C it takes about 5 minutes; at 70 °C, about one second. Store water at 60 °C or above (to kill Legionella — see below), but run baths cold first, then hot, and test with an elbow: a bath for a child should be about 37–40 °C, feeling just warm. Fit a mixing tap where children and the old bathe (Toilets, Sinks, Baths and Showers).

Danger Carbon monoxide from a gas geyser or water heater with no flue or a blocked one kills silently, often in a small closed bathroom. Every fuel-burning heater must have a flue to outside and fresh air (Chimneys, Stoves and Heating).

  • Legionnaires' disease. Bacteria that grow in water kept warm (20–45 °C) — in tepid cylinders, unused pipes and shower heads — cause a dangerous pneumonia when breathed in as spray. Keep stored hot water at 60 °C or above, run unused taps and showers for a few minutes each week, and keep cold water cold.
  • Burns from hot pipes and radiators, especially to babies and the old who cannot move away: guard them or keep them below about 60 °C on the surface.
  • Lead pipes and lead solder must never carry hot water: hot water dissolves lead fast (Lead).

Going further

Electric immersion heaters, kettles and storage heaters: Electric Kettles, Irons, Heaters and Cookers. Automatic control of boiler and room temperature: Thermostats and Automatic Control. Sun-heated water: Solar Heat. Underfloor heating by warm water pipes is the hypocaust and ondol of Chimneys, Stoves and Heating done with water. A town can heat many buildings from one central boiler house through insulated mains — district heating — and the waste heat of a power station or a factory can feed it (Heat Pumps and District Heating, The Steam Turbine).

How it was first done

Roman bathhouses heated water in bronze tanks over furnaces and warmed floors and walls with the hypocaust. Hot-water heating by pipes began in the late 1700s and early 1800s, at first to warm greenhouses and conservatories. In 1831 Angier March Perkins in London patented a small-bore, high-pressure hot-water heating system of sealed iron pipes. Kitchen ranges with back boilers spread through Britain in the mid-1800s. In America, Joseph Nason and Robert Briggs built early radiators of wrought-iron tubes screwed into cast-iron bases in the 1840s, and around 1855–57 Franz San Galli, a businessman in St Petersburg, made one of the first cast-iron sectional radiators. In 1868 Benjamin Maughan of London patented the first gas instantaneous water heater and named it the geyser. Around 1889 Edwin Ruud in Pittsburgh built an automatic gas storage water heater with a thermostat. Electric pumps (circulators) small enough for houses came into use in the 20th century, making the small-bore pumped systems most houses have today.

Source: content/entries/building/hot-water-and-central-heating.md