◆ Rebuild

Part 9 · Health and Medicine

Sterilising Instruments and Dressings

How to make instruments, dressings and hands safe to go into a wound — by boiling, steam under pressure, dry heat, alcohol and chlorine — how to wrap and store sterile packs, and how to run a clean operating room.

Difficulty
●●●●●
Time
20 minutes to boil a set of instruments; an hour or two for an autoclave or oven cycle
Steps from zero
6 prerequisites →

You need first

Sanitation and GermsDistillation

This unlocks

Blood Typing and TransfusionCulturing MicrobesDentistryThe First Aid KitRunning a HospitalIntravenous FluidsBasic SurgerySyringes and Hypodermic Needles
The full path from nothing — 6 steps before this one
  1. Fire
  2. Finding and Preparing Clay
  3. Sanitation and Germs
  4. Pottery
  5. Fermentation
  6. Distillation
  7. Sterilising Instruments and Dressings

Do them roughly in this order. See it on the tech tree →

Why it matters

Before about 1870, a surgeon washed his hands after an operation, not before, and wore a coat stiff with old blood as a mark of experience. Up to half of all amputations ended in death from infection — not from the operation itself, but from germs carried into the wound on fingers, knives, sponges and bandages. When surgeons learned to kill those germs first, deaths fell several-fold within a few years.

Sterilising — killing every living germ on an object — costs only heat and care. It is what turns Wound Care and Antiseptics, Safe Childbirth, Basic Surgery and Dentistry from gambles into reasonable risks. It also stops diseases such as hepatitis spreading from one patient to the next on a shared needle or blade.

How it works

Germs (Sanitation and Germs) are killed by heat, which "cooks" them, and by some chemicals, which poison them. Three facts decide everything:

  • Dirt protects germs. A film of blood, pus or grease shields germs from heat and chemicals. Every method fails on a dirty instrument. Clean first, always.
  • Spores are the hard part. Some bacteria — including those of tetanus and gas gangrene, which live in soil and dung — form spores: dormant seeds with tough coats that survive boiling for hours. Killing spores needs more than 100 °C: steam under pressure, or a hot dry oven.
  • Time at temperature. Heat must reach every surface and stay there long enough. Wet heat (steam) kills faster than dry heat at the same temperature because it carries heat into germs much better — like the difference between putting your hand into a hot oven and into steam at the same temperature.

Three words mean different things:

Word Means Example
Cleaning Removing dirt and most germs Scrubbing with soap and water
Disinfection Killing most germs, but not all spores Boiling; alcohol; chlorine
Sterilisation Killing everything, spores included Steam at 121 °C; dry heat at 160–180 °C
METHOD HEAT TIME AT TEMPERATURE Boiling100 °C Steam under pressure121 °C Steam under pressure134 °C Dry heat (oven)160 °C Dry heat (oven)170 °C Dry heat (oven)180 °C 20 min — kills almost all, but not every spore 20 min bare · 30 min wrapped 4 min bare · 15 min wrapped 2 h 1 h 30 min 0306090120 min Count time only once the whole load is at temperature. Pale part of a bar: extra time for wrapped packs.
Fig. 1 Time and temperature for each method. Boiling kills almost everything but not all spores; steam under pressure is fastest; dry heat is slowest but needs only an oven.

What you need

Item Use Source
Large pot with a lid, and a rack or cloth pad for the bottom Boiling Pottery, Sheet Metal and Rolling, Copper Smelting
Pressure vessel (autoclave or pressure canner) Steam sterilisation Built as in Canning and Bottling
Oven that holds 160–180 °C Dry heat A clay or brick oven (The Kiln, Grain, Flour and Bread) or a closed iron box in a fire
Soap, stiff brushes Cleaning Soap, Brooms, Brushes and Combs
Alcohol, 70% Skin, hands, surfaces Distillation
Chlorine bleach Surfaces, spills, soaking Chlorine and Bleach
Boiled cloth — linen or cotton Dressings, wrapping packs, towels Flax, Hemp and Linen, Cotton, Spinning and Weaving Cloth
Lidded tins or pots Storing sterile packs Sheet Metal and Rolling, Pottery
A few crystals of sulfur in a sealed glass tube Checking autoclave temperature Sulfur, Glass

Where to find it

Most of what you need is made in other chapters. Two raw materials are worth noting:

  • Native sulfur — yellow crusts around volcanic vents and hot springs, smelling of rotten eggs when heated (Sulfur). It melts at 115 °C, which makes it a free thermometer for an autoclave.
  • Hay — ordinary dried grass carries the spores of the harmless hay bacillus. Boiled hay water is a ready-made source of tough spores for testing whether your sterilising works (see How to tell it worked).

Step 1: Clean before you sterilise

  1. Rinse at once. After use, put instruments straight into a bowl of water so blood does not dry on them. If you have it, soak them first for 10 minutes in 0.5% chlorine (below) to protect the person cleaning them.
  2. Open and take apart anything that opens — scissors, forceps, syringes.
  3. Scrub every surface with a brush, soap and warm water, under the water's surface so it does not spatter. Pay attention to hinges, teeth of forceps, and the eyes of needles.
  4. Rinse and dry. Look at each one in good light. Any brown crust left is dried blood: scrub again.

Method 1: Boiling

Boiling is the simplest and most important method. It kills nearly all germs, including those of hepatitis and HIV, but not every spore. It is good enough for most instruments used on skin and in clean wounds, and for childbirth, when nothing better is available.

  1. Put a cloth pad or rack in the bottom of the pot so instruments do not rattle against hot metal or clay.
  2. Lay in the cleaned instruments, opened, and cover them completely with water — at least 2–3 cm above the top.
  3. Put the lid on and bring to a rolling boil — big bubbles breaking the surface all the time.
  4. Start timing only when it boils: 20 minutes. If you add anything during that time, start the 20 minutes again.
  5. Lift instruments out with boiled forceps or tongs, onto a boiled cloth, or leave them in the covered pot until needed. Use them within a few hours.

Above about 2,000 m, water boils below 95 °C; boil for 30 minutes there.

Method 2: Steam under pressure (the autoclave)

This is true sterilisation and the method every hospital uses. A sealed pot lets steam build up pressure, and the water then boils hotter than 100 °C. At 1 bar above normal air pressure (about 15 pounds per square inch), steam is at 121 °C; at 2 bar, about 134 °C. A pressure canner from Canning and Bottling is exactly this machine.

Weighted vent left open until steam has blown out all the air (5–10 min), then weighted Safety plug soft metal; melts if the vent blocks Lid clamped evenly Wrapped pack loose, not touching the walls Sulfur tube melts at 115 °C: proof of heat Rack keeps the load out of the water Water, 3–5 cm never let it boil dry Steam must reach every surface Instruments opened, in an open tray 1 bar → 121 °C · 2 bar → 134 °C (above normal air pressure)
Fig. 2 A simple autoclave. Instruments and wrapped packs sit on a rack above the water. Steam must first push all the air out through the open vent; then the weight closes it and the pressure rises. A plug of soft metal melts if the vent ever blocks.
  1. Water in the bottom, 3–5 cm deep, below the rack. Never let it boil dry.
  2. Load loosely. Packs and trays must not touch the walls or each other tightly; steam has to flow between them. Stand trays on edge or with their lids open. No pack bigger than about 30 × 30 × 50 cm.
  3. Close the lid with the vent open and heat.
  4. Purge the air. When steam comes out of the vent, let it blow freely for 5–10 minutes, until it is a steady, strong, invisible-at-the-nozzle jet rather than a spluttering white puff. Trapped air is the commonest cause of failure: a pocket of air inside a pack stays far cooler than the steam around it.
  5. Close the vent (put the weight on). The pressure rises. When the weight lifts and starts to hiss or rock, you are at pressure.
  6. Hold it there, adjusting the fire so the weight just rocks gently:
    • 121 °C (1 bar): 20 minutes for unwrapped instruments; 30 minutes for wrapped packs and dressings.
    • 134 °C (2 bar): 4 minutes unwrapped; 15 minutes wrapped.
  7. Cool slowly. Take it off the fire and let the pressure fall on its own. Never open the lid or force the vent while there is pressure inside.
  8. Dry. When it is cold enough to open safely, lift the lid a crack and leave the packs in the warm vessel for 15–30 minutes to dry. A pack that comes out damp wicks germs through its wrapping as soon as it touches anything; treat it as unsterile.

Method 3: Dry heat

Hot air sterilises metal, glass and powders, and does not rust or blunt instruments the way repeated boiling does. It does not suit cloth (it scorches) or rubber (it melts and perishes).

Oven temperature Time, counted after the load is hot
160 °C 2 hours
170 °C 1 hour
180 °C 30 minutes
  • Load clean, dry instruments in a closed metal box or wrapped in a double layer of thick paper. Leave space for heat to circulate.
  • Judging 160–180 °C without a thermometer is rough. One test: put a few crystals of white sugar in a tin lid on the shelf. At these temperatures they slowly melt and turn pale gold over the hour; if they blacken in minutes, the oven is far too hot; if they have not begun to change by the end, it was too cool. Better still, make a thermometer (The Thermometer).
  • Do not exceed 200 °C for fine blades and needles; more heat softens tempered steel (Steel).

Method 4: Flame

Holding a needle, wire loop or blade tip in a flame until it glows red sterilises it instantly. It also destroys the temper of steel, so use it only for needles to open blisters, wire loops in the laboratory (Culturing Microbes), and emergencies. Dipping in alcohol and setting it alight is not enough: the alcohol burns at the surface and the metal barely warms.

Method 5: Chemicals

Chemicals disinfect; they do not reliably sterilise. Use them for skin, hands, surfaces and things heat would ruin.

  • Alcohol, 70% (Distillation). Weaker than 60% works poorly; stronger than 90% evaporates before it kills. Rub on skin and let it dry completely (about 30 seconds) before cutting. Wipe surfaces and leave them wet for 2 minutes. It does not kill spores.
  • Chlorine (Chlorine and Bleach). Strength is given as available chlorine. Household-strength bleach is about 5%: 1 part bleach to 9 parts water makes 0.5%, for surfaces, blood and pus spills, and soaking used instruments for 10 minutes before cleaning. Diluted 10 times more (0.05%), it can be used to wash hands when there is no soap. Make it fresh each day; rinse instruments afterwards with boiled water, because chlorine corrodes steel.
  • Iodine, if you can obtain it from seaweed ash (Iodine), makes an excellent skin antiseptic as a 2% solution in alcohol.
  • Sunlight and drying reduce germs on cloth but do not sterilise it.

Preparing sterile dressings and packs

  1. Cut linen or cotton cloth into squares (10 × 10 cm pads made from larger pieces folded 4–8 layers thick) with the cut edges folded inward, so no loose threads can come off in a wound. Make bandage rolls 5–10 cm wide.
  2. Wash and boil the cloth, rinse out all soap, and dry it.
  3. Make packs of what one job needs — say, 10 pads, 2 bandages and a towel; or the instruments for one suturing. Wrap each in two layers of cloth using the envelope fold, so it can be opened without touching the inside.
date · contents tab 1 Contents in the middle cloth laid corner-wise, two layers 2 Near corner over covering the contents 3 Left, then right side folded in snugly 4 Far corner down tip left out as a tab; tied with tape, labelled To open: pull the tab and unfold the corners away from you, touching only the outside.
Fig. 3 Wrapping a sterile pack in an envelope fold. Fold the near corner over the contents, then the sides, then the far corner, leaving its tip as a tab. Whoever opens it pulls the tab and unfolds the corners away from the contents, touching only the outside.
  1. Label with the contents and the date, and sterilise by steam (best) or, for cloth without a pressure vessel, by steaming in a covered pot over boiling water for 30 minutes on three days in a row (spores that survive the first day sprout and die the next — see Penicillin). As a last resort, boiled and dried cloth ironed on both sides with a very hot iron is much cleaner than untreated cloth.
  2. Store packs dry, in closed tins or pots, off the floor. A pack stays sterile until it is opened, torn, wet or dropped. Re-sterilise packs older than about a month unless they are sealed in tins.

Hands, clothing and the operating room

Surgical hand scrub. Nails short, no rings. Wash hands and forearms to just above the elbows with soap for 3–5 minutes, scrubbing nails and between fingers with a boiled brush. Rinse with hands held up, so water runs off the elbows, never back onto clean hands. Dry on a sterile towel, then rub in 70% alcohol and let it dry. If you have rubber gloves (Rubber), steam them and put them on without touching their outsides with bare skin.

The room.

  • Smooth, washable walls and floor — lime-washed (Lime) or plastered — and a table you can scrub.
  • Good light: a big window (cloth-screened against flies) and the operation by day if possible.
  • Few people, little talking. Everyone near the wound wears a cloth over the mouth and nose and a cap, and a freshly boiled apron or gown.
  • Wipe the table and surfaces with 0.5% chlorine before and after. Boil all used cloth.
  • Later, filtered air blown gently down over the table cuts infection further still, especially for bone and joint operations (Clean Rooms).

The sterile field. Lay a sterile cloth on a small table and open the packs onto it. Then follow four rules:

  1. Only sterile touches sterile. The scrubbed person handles the instruments; an unscrubbed helper opens outer wrappings by touching only the outside and passes things by dropping them onto the field.
  2. Keep everything above the waist and in front of you. Anything that drops below the table edge is unsterile.
  3. Never reach across a sterile field with an unsterile arm.
  4. If in doubt, it is dirty. Replace it.

Warning Needles, syringes and blades must be sterilised between every patient. Re-using them unsterilised spreads hepatitis B and C and HIV, which kill years later. This happened on a vast scale in twentieth-century mass injection campaigns, such as Egypt's treatment of bilharzia, which spread hepatitis C to millions. One clean needle per person, every time.

How to tell it worked

  • Sulfur tube. Seal a few sulfur crystals in a small glass tube and put it in the middle of a pack. After the cycle, the crystals should have melted and run together into a droplet. If they have not, the centre never reached 115 °C: you did not purge the air, or the pack was too big or packed too tight. Melting proves only 115 °C, not the 121 °C you need, so it catches gross failures; the spore test below is the real proof.
  • Spore test. Boil a handful of hay in water for 10 minutes and let it stand for a few days; the cloudy film that forms is full of hay bacillus, whose spores survive boiling. Dip small strips of cloth in it and let them dry. Put one strip in the middle of a pack and run the cycle. Then drop the strip into a tube of boiled, cooled broth (sterilised the same way) and keep it warm for 2–3 days alongside an untreated strip in a second tube. The untreated tube should turn cloudy; the sterilised one should stay clear. See Culturing Microbes.
  • The long test: keep a record of every operation and every wound infection. Infections after clean operations should be rare — a few in a hundred. If they are more, find out why.

Note Troubleshooting. Sulfur not melted in the autoclave → air trapped; purge longer, load more loosely, use smaller packs. Packs come out wet → too much water touching the load, or not dried in the warm vessel; raise the rack, and dry with the lid ajar. Instruments rusting → too much boiling or chlorine; dry them at once, and switch to dry heat for metal. Cloth scorched in the oven → cloth should go in steam, not dry heat. Brown stains on "clean" instruments → dried blood; it was never cleaned properly, so it was never sterile.

Dangers

Danger A pressure vessel can explode like a bomb if its vent blocks. Use a vent that cannot clog, a safety plug of soft metal that melts above the working temperature, and a lid that is clamped evenly. Never open it under pressure; never stand over it while it is pressurised. See Canning and Bottling and Pressure Vessels and Valves.

Never mix chlorine bleach with acids, vinegar, ammonia or urine. It releases chlorine or chloramine gas, which can kill in an enclosed room.

  • Scalds from boiling water and steam are worse than they look. Lift lids away from you.
  • Alcohol burns with a nearly invisible flame. Keep it away from fires and lamps, and let it dry on skin before anyone uses a flame or hot cautery nearby.
  • Burns from hot instruments: let them cool before they touch a patient.

What this unlocks

Sterile instruments and dressings make Basic Surgery, Dentistry and Anaesthesia reasonable risks, make Safe Childbirth safer, and allow you to give injections — of vaccines, and later of Penicillin or a Blood Typing and Transfusion. The same autoclave and sterile technique are the foundation of Culturing Microbes.

How it was first done

In 1847 the Hungarian doctor Ignaz Semmelweis, in Vienna, made doctors wash their hands in chlorinated lime before examining women in childbirth, and deaths from childbed fever in his ward fell from over 10% to around 1–2% — but colleagues mocked him and his rule lapsed. In 1867 Joseph Lister in Glasgow began soaking instruments and dressings in carbolic acid, and deaths after amputation in his wards fell sharply. In 1679 Denis Papin had built a "steam digester" — the first pressure cooker — but it was Pasteur's assistant Charles Chamberland who made the autoclave for sterilising in 1879. German surgeons, especially Ernst von Bergmann and Curt Schimmelbusch, made steam sterilisation of instruments and dressings routine around 1890, replacing chemical antisepsis with asepsis — keeping germs out in the first place. William Halsted introduced rubber gloves at Johns Hopkins in 1890, at first to protect a nurse's hands from harsh antiseptics; Jan Mikulicz wore a cloth face mask in 1897.

Source: content/entries/health/sterilization.md