◆ Rebuild

Part 9 · Health and Medicine

X-Rays

Seeing inside a living body without opening it — how a vacuum tube and a high voltage make X-rays, how to record the shadow on a photographic plate, what the picture is actually worth, and why the people who first did this died of it.

Difficulty
●●●●●
Time
Months to build a working tube; a minute to take a picture; a lifetime of damage if you are careless
Steps from zero
31 prerequisites →

You need first

The Vacuum TubeThe Induction Coil

This unlocks

Ultrasound, CT and MRIRadiotherapy (Overview)Particle Accelerators (Overview)
The full path from nothing — 31 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. The Kiln
  9. Pottery
  10. Charcoal
  11. Hides and Leather
  12. Lime
  13. Mercury
  14. Lye and Potash
  15. Fermentation
  16. The Wheel and Axle
  17. Glass
  18. Bellows
  19. The Lathe
  20. Copper Smelting
  21. Iron (the Bloomery)
  22. Laboratory Glassware
  23. Pumps
  24. Blacksmithing
  25. The Battery
  26. The Vacuum Pump
  27. The Light Bulb
  28. Copper Wire
  29. The Electromagnet
  30. The Vacuum Tube
  31. The Induction Coil
  32. X-Rays

Do them roughly in this order. See it on the tech tree →

Why it matters

For all of history before 1896, the inside of a living body could be known only by touch, by sound, by guesswork and by cutting it open. Then a physicist noticed a glow in a darkened room, and within three months doctors on four continents were locating bullets, setting broken bones against a picture, and finding tuberculosis in a chest that sounded normal.

X-rays are worth building when you can, because they answer questions nothing else answers:

  • Is this bone broken, and did my setting of it work? The single most useful application, and the one that most changes what you do (Wound Care and Antiseptics, Basic Surgery).
  • Where exactly is the foreign body — a needle, a shard, a swallowed coin?
  • What is in this chest? Tuberculosis, pneumonia, fluid, a collapsed lung.
  • Is this swelling bone, abscess or tumour? Is this tooth abscessed (Dentistry)?

Warning Be clear about the cost. This machine needs a high vacuum, 40,000 volts or more, glassblowing, a metal target that survives being white-hot, and photographic chemistry — in other words most of the Electricity and Knowledge parts of this book. And its product is invisible, silent, painless radiation that burns, blinds and causes cancer years later. A careful examination with hands, eyes and ears (Examining a Patient) answers the great majority of medical questions without any of this. Build X-rays when your society is ready for them, not before.

How it works

Cathode a cup of aluminium: its curve focuses the electrons electrons, 40–100 kV Target (anticathode) platinum or tungsten, a thick block at 45° Over 99% of the energy arrives here as heat X-rays out in all directions — only the beam you let through the lead is useful Regulator warm it gently to let a little gas back in when the tube goes "hard" from the induction coil to the other terminal Inside: a trace of gas left, about one hundred-thousandth of air pressure
Fig. 1 A gas X-ray tube. A high voltage drives electrons from the cup-shaped cathode onto a slanted metal target; where they stop, X-rays are born. Over 99% of the energy becomes heat, which is why the target is a thick block of heavy metal.
  1. Boil off or tear off some electrons inside a glass bulb from which nearly all the air has been pumped (The Vacuum Pump).
  2. Accelerate them across the bulb with a very high voltage — 40,000 to 100,000 volts — from an The Induction Coil or an influence machine (Static Electricity and the Leyden Jar).
  3. Stop them suddenly in a block of heavy metal (platinum, tungsten). When a fast electron is slammed to a halt, a little of its energy comes out as light of enormously short wavelength: X-rays. More than 99% comes out as heat, which is why the target glows and why it must be a thick slab of a metal that will not melt.
  4. The rays go through things. They pass easily through flesh and water, less easily through bone (which is full of calcium), and hardly at all through lead or other heavy metals. So a body placed between the tube and a photographic plate casts a shadow picture: bones pale, soft tissue dark, metal white.

Two numbers control the picture: the voltage decides how penetrating the rays are (40–50 kV for a hand, 60–70 for a chest, 70–90 for a hip), and the current × time decides how many there are, and so how dark the plate becomes.

Two kinds of tube

The gas tube (Crookes, Jackson, "focus" tube) — the only one achievable at first. The bulb is not fully evacuated: a trace of gas is left, around a millionth of normal air pressure. The high voltage ionises that gas; the positive ions bombard a cup-shaped aluminium cathode, which throws off electrons; the cup's curve focuses them on a slanted target.

  • Simple to make: no filament, no supply of heating current.
  • Unstable. As it runs, the glass absorbs gas and the tube goes "hard" — higher voltage, more penetrating rays, less current, eventually nothing. Early tubes had a side-arm "regulator" containing mica or asbestos; warming it with a flame released a little gas and softened the tube again. You will spend much of your time managing this.
  • You cannot set voltage and quantity independently: they rise and fall together.

The hot-cathode tube (Coolidge, 1913) — what you should aim for eventually. A tungsten filament, heated by its own small current, boils off electrons freely; the bulb is pumped as hard as possible with no gas left at all. Voltage and current are then controlled separately and the tube behaves the same way every day. It needs a far better vacuum (a mercury diffusion pump, High-Vacuum Pumps and Gauges), tungsten wire (Tungsten and Filament Wire, The Light Bulb) and a rotating or massive anode to take the heat.

Judging the voltage without a meter: connect a spark gap with two sharp needle points across the tube and open it until the spark just stops jumping. As a rough guide, a spark crossing about 5 cm between sharp points means roughly 50 kV, and about 15 cm roughly 100 kV. (Between rounded balls the same voltage jumps a much shorter gap, so always use the same pair of points.) Treat all such figures as approximate; the useful part is consistency — once you find a setting that gives a good picture of a hand, write it down and reproduce it.

What you need

Item Notes
A tube Hand-blown glass, 15–20 cm bulb; aluminium cathode cup; platinum or tungsten target set at 45°; electrodes sealed through the glass (Glass, Window Glass)
A vacuum pump Mercury-piston (Sprengel/Töpler) pump for a gas tube; diffusion pump for a hot-cathode tube. See The Vacuum Pump
High voltage An The Induction Coil with an interrupter, or a large influence machine. The influence machine is easier to build and needs no interrupter, but gives little current, so exposures are long
A lead diaphragm A lead sheet with a hole, close to the tube, to cut the beam down to just the part being examined. Made from Lead (from galena ore)
Plates or film Glass plates coated with silver bromide gelatin emulsion: see Photography
Intensifying screens Cardboard coated with calcium tungstate (from wolframite and Lime) or zinc sulfide (from sphalerite). They glow where X-rays strike and expose the plate ten to twenty times faster — the single biggest reduction in dose available to you
A darkroom and developer Photography again
Shielding Lead sheet 2–3 mm thick, or a wall of 15 cm of concrete or two bricks' thickness, or 25 cm of water
Sandbags, cloth ties, wooden blocks To hold the patient still. Never a person's hands

Where to find it

  • Lead for shielding and diaphragms comes from galena — bright lead-grey, cubic, extremely heavy (Lead, Finding and Identifying Ores).
  • Tungsten for targets and filaments comes from wolframite, dark brown-black bladed crystals in quartz veins near granite, usually alongside tin ore. It is hard to smelt (Tungsten and Filament Wire); a platinum target is easier if you have any platinum (Platinum and the Platinum Metals).
  • Zinc sulfide for fluorescent screens comes from sphalerite (zinc blende), resinous brown crystals in limestone veins (Zinc and Brass).
  • Barite (barium sulfate) — heavy, pale, tabular crystals, often in veins with galena — makes the "barium meal" that a patient swallows so the stomach shows up, and is also the base of early fluorescent screens.

Step by step: taking a radiograph

The tube target at the top, beam pointing down Lead diaphragm: shut the beam down to the part you are examining About 1 m target to plate: closer blurs the picture and burns the skin Sandbags, not hands never hold a patient; plate in its cassette, the limb flat on it Barrier 2–3 mm of lead, two bricks, or 15 cm of concrete Distance works like lead: at 2 m the dose is a quarter of what it is at 1 m, at 4 m a sixteenth. You feel nothing at all while this happens. The burn appears two to four weeks later.
Fig. 2 The layout of a radiograph, and the three protections. The beam is cut down to the part being examined, the plate is a metre from the target, the patient is held by sandbags, and everyone else is behind the barrier.
  1. Set the room. A dark, dry room. The tube on a wooden stand, the patient's part flat against the plate holder, the plate in a light-tight wooden cassette with an intensifying screen on each side.
  2. Distance. Set the target about 1 metre from the plate. Closer makes a blurred, distorted picture and greatly increases the dose to the skin; much further needs impossibly long exposures.
  3. Collimate. Shut the beam down with the lead diaphragm so only the part being examined is in it. This improves the picture (less scattered fog) and protects everyone.
  4. Position and immobilise. The part flat against the plate, held with sandbags and ties. Instruct the patient: do not move; for a chest, take a breath in and hold it.
  5. Everyone else behind the barrier. You included.
  6. Expose. With a gas tube and an induction coil, a hand may need 5–30 seconds; a chest or a pelvis, a minute or more; with an influence machine, several minutes. Find your exposures by trial on a dead animal's limb, and write every one down in a table — voltage setting, distance, thickness of part, time. That table is your instrument.
  7. Develop in the darkroom as for any photographic plate: develop, stop, fix, wash thoroughly, dry (Photography).
  8. Read it against a lamp, with a sheet of card to mask the glare around the edges.

Fluoroscopy — the dangerous shortcut

If you hold a fluorescent screen behind the patient instead of a plate, you see the shadow live and moving: a fracture reducing under your hands, a swallowed object sliding. This is fluoroscopy, and it was the first use of X-rays. It is also the greatest source of radiation injury in the history of medicine, because the tube runs continuously, often for minutes, with the operator's eyes and hands in or near the beam. Shoe shops fluoroscoped children's feet for fun from the 1920s to the 1950s, giving millions of children, and the staff who stood beside the machine all day, radiation for nothing.

If you must do it: the shortest glimpses possible, a lead-glass screen between your eyes and the beam, lead apron and gloves, the smallest beam, and never your own hand in the field.

How to tell it worked

  • A correctly exposed plate shows bone clearly white, soft tissue in grey, and the open air around the limb black. Through a well-exposed chest you can just make out the outlines of the spine behind the heart.
  • Too pale and flat → underexposed (too short, or the tube has gone "hard" and current fell).
  • Too dark, no detail → overexposed, or the plate was fogged by light, by stray X-rays or by old emulsion.
  • Sharp edges mean the patient stayed still and the distance was right. Blur means movement or a tube too close.
  • Prove the geometry before you trust the picture: radiograph a known object — a dead animal's leg, a dry bone with a hole drilled in it — and compare.

Note Troubleshooting. Nothing at all on the plate → tube not making rays (gone too hard), plate loaded backwards, exposure far too short, or the beam missed the plate. Test the tube by standing a fluorescent screen on a stand a metre away in the dark and watching it from behind the barrier for a second: it should glow faintly green. The tube glows a soft blue-green inside and little comes through the patient → too soft (too much gas): rays too weak to penetrate. Run it to harden it. Violent sparks jumping around the outside of the tube → the tube is too hard, so the voltage has nowhere to go. Warm the regulator a little; stop before you puncture the glass. The target glows red and the glass cracks → too much current for too long. Longer rests between exposures; a bigger target block. Fogged, grey plates every time → stray radiation reaching the plate store. Keep unused plates in a lead-lined box in another room.

Dangers

Danger X-rays cause no sensation whatever. You cannot feel, see, hear or smell a dose that will burn you. The burn appears two to four weeks later as a red, then raw, then ulcerated patch that may never heal and may turn cancerous decades afterwards. The early workers learned this by losing fingers, hands and arms, and then dying of cancer: Clarence Dally, Edison's assistant, died in 1904 after both arms were amputated, and a monument in Hamburg lists 359 of the profession's dead. Assume every exposure does permanent harm and arrange your work to need as few as possible.

The three protections, in order of power:

  1. Time — fewer and shorter exposures. Never "just take another one".
  2. Distance — dose falls as the square of the distance. Two metres away is a quarter of the dose at one metre; four metres, a sixteenth. Standing well back is nearly as good as shielding.
  3. Shielding — 2–3 mm of lead, 15 cm of concrete, a double-brick wall, or a good 25 cm of water between you and the tube. Lead-glass for a viewing window; if you have none, a mirror and an angle.

Absolute rules, each of them written in somebody's amputated hand:

  • Never put any part of yourself in the beam. Not to test the tube, not to hold a plate, not to show someone the bones of your fingers.
  • Never hold a patient. Use sandbags, ties and blocks. If a child truly must be held, let a relative who is neither pregnant nor young do it, in an apron and gloves, with their hands out of the beam — and do it once.
  • Never X-ray the abdomen or pelvis of a pregnant woman unless her life depends on the answer. The unborn child is many times more sensitive than an adult.
  • Shut the beam down with the diaphragm to the smallest field that answers the question.
  • Keep a logbook of every exposure, who was in the room and where they stood.
  • Make a crude dose monitor: wrap a small piece of unexposed photographic film in black paper and wear it on your chest for a week, then develop it alongside an unworn piece from the same batch. If yours is noticeably darker, your practice is wrong (Detecting Radiation covers better instruments). The accepted limits are 20 mSv a year for people who work with X-rays and 1 mSv a year for the public (Radiotherapy (Overview)). The early radiologists used a pastille of barium platinocyanide that changed colour as it absorbed radiation — the same idea.
  • Electrical danger is immediate and separate. An induction coil or influence machine delivers tens of thousands of volts. It can kill you outright, and it will certainly throw you across the room. Insulate every lead, mount the tube on dry wood or glass, keep one hand behind your back when the power is live, and never work alone. See Wiring and Electrical Safety.
  • Ozone and nitrogen oxides build up in a closed room running a high-voltage spark: a sharp, metallic smell, and irritated lungs. Ventilate.

What this unlocks

An X-ray tube is a The Vacuum Tube with a particular job, and building one teaches the skills — glass-to-metal seals, high vacuum, high voltage, hot cathodes — on which Radio, Cathode Rays and Television and all electronics rest. The fluorescent screen leads to the photographic detection of invisible things. And in medicine, the ability to see a fracture's alignment, a stone, a swallowed object or a diseased lung turns Basic Surgery from a gamble into a planned operation. The same tubes, run harder, treat cancer (Radiotherapy (Overview)), and the later ways of seeing inside the body — ultrasound, CT and MRI — build on this one (Ultrasound, CT and MRI).

How it was first done

On the evening of 8 November 1895, Wilhelm Conrad Röntgen was working in a darkened laboratory in Würzburg with a Crookes tube wrapped in black card. A small screen painted with barium platinocyanide, lying a metre away, glowed. Nothing known at the time could cross that gap through card. Over the next seven weeks he worked almost without leaving the room, established that the new rays travelled in straight lines, were not deflected by magnets, passed through flesh but not bone or lead, and darkened photographic plates. He called them X, for unknown.

On 22 December 1895 he made a 15-minute exposure of his wife Anna Bertha's hand; the plate shows her finger bones and her ring. She is said to have remarked, "I have seen my death." He published on 28 December, and sent copies with photographs to physicists across Europe on New Year's Day. The news travelled the world in a week, and because Röntgen refused to patent anything, anybody with a Crookes tube and an induction coil — which meant every physics teacher in Europe and America — could repeat it within days. A needle was found buried in a hand in Birmingham in January 1896; in February a bullet was located in a man's leg in Montreal and a broken wrist was radiographed in New Hampshire. Röntgen received the first Nobel Prize in Physics in 1901 and gave the money away.

The improvements that made it safe and reliable came more slowly: Michael Pupin's intensifying screen (1896), which cut an exposure from many minutes to seconds; William Coolidge's hot-cathode tube (1913), which made the dose repeatable; flexible film replacing glass plates after 1918; and the dawning realisation, paid for in the hands and lives of the first generation of radiologists, that the beautiful invisible light must be used as sparingly as possible.

Source: content/entries/health/x-rays.md