Part 10 · Machines
High-Vacuum Pumps and Gauges
Getting from a rough vacuum to a millionth of a millimetre of mercury and knowing you are there. The oil-sealed rotary vane pump that does the heavy work, the diffusion pump that finishes it, cold traps, getters and sorption pumps, joints that do not leak and how to find the ones that do, and the Pirani and ionisation gauges that read pressures far below any mercury column — with a guide to what each job really needs.
- Difficulty
- ●●●●●
- Time
- Three to four weeks in a machine shop for a first rotary pump; a week for a Pirani gauge; a month to put together, bake and leak-test a complete high-vacuum bench
- Steps from zero
- 32 prerequisites →
The full path from nothing — 32 steps before this one
- Fire
- Stone Tools
- Cordage and Rope
- Finding and Preparing Clay
- Finding and Identifying Ores
- Sulfur
- Basic Woodworking
- Hunting and Trapping
- The Kiln
- Pottery
- Charcoal
- Hides and Leather
- Lime
- Mercury
- Lye and Potash
- The Wheel and Axle
- Glass
- Bellows
- Saltpeter
- The Lathe
- Copper Smelting
- Lead
- Laboratory Glassware
- Sulfuric Acid
- Pumps
- Lenses
- Gold and Silver
- Nitric Acid
- The Vacuum Pump
- Silver Nitrate and Silver Salts
- Mirrors
- Vacuum Coating and Thin Films
- High-Vacuum Pumps and Gauges
Do them roughly in this order. See it on the tech tree →
Why it matters
The piston, water-jet and Sprengel pumps of The Vacuum Pump are slow and small and stop near a thousandth of a millimetre of mercury. The vacuum coater introduced the diffusion pump. This chapter builds a proper high-vacuum system: a strong mechanical pump, a vapour pump, traps, sound joints, and gauges that tell you what you have.
High vacuum makes radio valves, X-ray tubes and Cathode Rays and Television tubes; mirror and lens coatings; vacuum-insulated vessels for liquid gases (Cryogenics and Superconductors); melted Titanium; Lasers; and the machines of Making Microchips.
How it works
Units. As in The Vacuum Pump, pressure is in millimetres of mercury (mm); air is 760 mm. One mm is about 133 pascals or 1.33 millibar; the torr is the same as the mm. 10⁻⁶ mm means a millionth of a mm.
| Range | Pressure (mm) | Distance a molecule flies before a collision | Behaviour |
|---|---|---|---|
| Rough | 760 – 1 | under 0.05 mm | Gas flows like a thick fluid |
| Fine | 1 – 10⁻³ | 0.05 mm – 5 cm | In between |
| High | 10⁻³ – 10⁻⁷ | 5 cm – 500 m | Molecules fly wall to wall |
| Ultra-high | below 10⁻⁷ | kilometres | Surfaces matter more than the gas |
No single pump does it all. A mechanical pump traps pockets of gas and pushes them out — fine while each pocket holds plenty, hopeless once a few molecules leak back past the seals. A vapour pump knocks molecules one way: useless at high pressure, excellent once they fly freely. So a backing pump (rotary) brings the system to about 0.05 mm and holds the vapour pump's outlet there, and a diffusion pump goes on to 10⁻⁶ mm.
Wide and short pipes. At high vacuum the gas no longer flows; molecules wander, and the pipe limits them. A tube d cm wide and L cm long passes about 12 × d³ ÷ L litres a second of air. A 2 cm tube 50 cm long passes 2 L/s — it would throttle a 300 L/s pump to nothing. Put the pump right under the chamber.
The walls are the enemy. Once the air is out, gas keeps coming off every surface — above all water, a few molecules thick on anything that has seen air. This outgassing sets how long high vacuum takes. Clean surfaces, few plastics and baking are the cure.
What different jobs need
| Job | Pressure (mm) | Equipment |
|---|---|---|
| Vacuum distillation, filtering, drying | 1–50 | Water jet or rotary (Distillation) |
| Freeze-drying food, plasma, vaccines | 0.05–0.5 | Rotary and a cold condenser (Preserving Food) |
| Light bulbs before gas filling | 10⁻³–10⁻⁴ | Rotary, then diffusion (The Light Bulb) |
| Mirror and lens coating; vacuum flasks | 10⁻⁴–10⁻⁵ | Rotary + diffusion + cold trap |
| Melting titanium, vacuum furnaces | 10⁻³–10⁻⁵ | Large rotary + diffusion (Electric Kilns and Furnaces) |
| Radio valves, X-ray and picture tubes | 10⁻⁶, then a getter | Diffusion + trap + bake + getter |
| Particle accelerators, chip-making tools | 10⁻⁹ and below | Baked metal systems with metal seals |
Do not build for a better vacuum than the job needs; each factor of ten below 10⁻⁴ mm costs more care, time and better joints.
What you need
| Item | Use | Source |
|---|---|---|
| Cast iron or steel; lathe, grinder, lapping plates | Pump bodies, fits of hundredths of a mm | The Lathe, Precision Grinding |
| Vacuum-distilled petroleum oil | Pump fluids | Petroleum and Refining, Distillation |
| Copper and steel tube and sheet | Pipework, traps, flanges | Metal Pipes and Tubes, Sheet Metal and Rolling |
| Rubber cord | O-rings | Rubber, Packing, Gaskets and Seals |
| Hard glass, tungsten and platinum wire | Gauges | Scientific Glassblowing and Glass-to-Metal Seals, Tungsten and Filament Wire |
| Liquid nitrogen or dry ice | Cold traps | Liquid Air, Nitrogen and the Noble Gases |
| Electric motor ¼–1 kW | Drive | The Electric Motor |
The rotary vane pump
A cylinder (the stator) with a smaller rotor turning inside it off-centre, nearly touching along one line — the top seal. Two vanes slide in a slot through the rotor, pushed against the bore by a spring and by spinning. Each vane sweeps gas from the inlet round the bore; the space ahead of it shrinks, and the gas leaves through an exhaust valve. The stator is sunk in oil, which seals every clearance. Dry, it would reach perhaps 10 mm; oiled, 0.01 mm.
Sizes for a small pump (about 4 m³ an hour)
| Part | Size |
|---|---|
| Stator bore | 60 mm across, 60 mm long |
| Rotor | 50 mm across, 5 mm off-centre, clearing the bore at the top seal by 0.01–0.03 mm |
| Vanes | two, hardened steel or laminated phenolic, 59 mm long, 5–6 mm thick, 0.01–0.02 mm play in the slot |
| End plates | lapped flat; end clearance 0.01–0.02 mm |
| Ports | 10–12 mm, either side of the top seal |
| Exhaust valve | spring-steel or rubber flap, under 1–2 cm of oil |
| Speed | 450–1,450 turns a minute, belt from a ¼–½ kW motor |
Displacement per turn ≈ π × (R² − r²) × length, with R and r the bore and rotor radii: here 52 cm³ a turn, 75 litres a minute at 1,450 turns.
Making it
- Stator. Bore a cast-iron or steel block truly round on the The Lathe; hone or lap the bore smooth and parallel; lap the ends flat.
- End plates of lapped steel carry the rotor bearings, bored from one setting so the rotor runs exactly parallel to the bore.
- Rotor. Turn it on its shaft and mill a slot clean through its full length; grind the slot faces parallel.
- Vanes. Grind them to slide through the oiled slot under their own weight without rocking; round their tips to the bore; put a light coil spring between them.
- Top seal. Shim until the rotor just clears a 0.02 mm feeler and turns freely by hand.
- Seals and oil. A leather or rubber lip seal on the shaft, running in oil (Packing, Gaskets and Seals); a 0.5–1 mm hole from the oil bath into the stator near the inlet, so the pump sips oil continually.
- Box. Fit the exhaust flap and stand the stator in an oil box holding 0.5–1 litre, with a sight glass and an exhaust baffle to catch oil mist.
Two stages — two stators on one shaft, the first exhausting into the second — reach 10⁻³ mm instead of 0.01–0.05 mm.
Gas ballast. Pumped water vapour condenses into the oil as it is squeezed, then boils back into the inlet; the pump stalls at a few tenths of a mm and the oil turns milky. A needle valve that leaks a little air into the compression space stops the condensing. Open it for wet systems and to clean the oil; close it for the best vacuum.
The oil. Distil a light lubricating oil from Petroleum and Refining under the best vacuum you have and keep the middle third: thin as machine oil, barely volatile. Change it when dark or milky.
Good and bad
- Blank-off test. With the inlet closed onto a gauge, a good single-stage pump reaches 0.05 mm or less in five minutes; two-stage, 0.005 mm.
- Sound. It gurgles at first, then settles into a sharp, regular knock as the vanes slap oil at the exhaust valve. A pump that never knocks has a leak.
- Heat. Warm, 50–70 °C, never too hot to touch for a second.
- Suck-back. Stopped under vacuum, it pushes oil back up the inlet pipe. Close the valve to the system and let air into the pump inlet before stopping.
The diffusion pump
Its construction is in Vacuum Coating and Thin Films: a boiler of oil or mercury under a stack of umbrella jets inside a water-cooled wall, with a foreline to the backing pump. For a system:
- Speed ≈ 4 litres a second per cm² of mouth: 5 cm pump about 80 L/s, 10 cm about 300, 15 cm about 700. Heaters of 200–300 W, 400–600 W and about 1 kW.
- Backing. The jets fail if the outlet rises above a few tenths of a mm, and vapour then backs up into the chamber. Keep the foreline below 0.05 mm: a rotary pump of about 1 m³ an hour for every 25–40 L/s of diffusion pump.
- Fractionating. Feed the top jet from a separate inner chimney, so that the lightest part of the oil boils off in the lower jets and only the heaviest faces the chamber. It gains a factor of ten.
- Ultimate: about 10⁻⁵ mm with oil and a water-cooled baffle; 10⁻⁶–10⁻⁷ mm with a liquid-nitrogen trap.
- Mercury or oil. Mercury never burns or decomposes, but its vapour is 10⁻³ mm at room temperature, so it must have a cold trap, and it is poisonous (Mercury). Oil needs no trap for 10⁻⁵ mm, but cracks if overheated and burns if air reaches it hot.
The cold trap
A very cold surface in the pumping line. Vapours that touch it freeze there: oil creeping back from the pump, mercury, and above all water from the walls.
| Coolant | Temperature | Water vapour left |
|---|---|---|
| Ice and salt | −20 °C | about 0.8 mm — little use |
| Dry ice in alcohol | −78 °C | about 0.0005 mm |
| Liquid nitrogen | −196 °C | none measurable |
Making one. A re-entrant trap: a closed inner can, open at the top for coolant, hanging inside an outer vessel through which the gas passes. Blow small ones of hard glass (Scientific Glassblowing and Glass-to-Metal Seals); make large ones of copper with fins in a steel housing on O-ring flanges. There must be no straight line of sight from pump to chamber, yet the passage must be as wide as the pump mouth.
Use. Fill it after the diffusion pump is hot and the system is under vacuum, and keep it topped up; a 1-litre trap lasts 4–8 hours. When it warms, everything it caught comes off at once, so close the high-vacuum valve first. A water-cooled baffle of overlapping copper chevrons just above the diffusion pump catches most oil with no coolant.
Getters and the sorption pump
A getter swallows gas chemically. Barium or magnesium flashed inside a sealed tube cleans it for life (The Vacuum Tube). In a working system, a titanium wire heated by current to about 1,500 °C coats the cooled walls round it with fresh metal that captures oxygen, nitrogen, hydrogen and water, though not noble gases (Titanium).
The sorption pump uses no oil at all. Fill a steel or copper canister with 1–2 kg of zeolite, a mineral full of molecule-sized holes (Water Softening and Ion Exchange), or activated charcoal (Activated Charcoal). Valve it to the chamber and dip it in liquid nitrogen: the cold zeolite soaks up air and pumps a 20-litre chamber from atmosphere to about 0.01 mm in 15–20 minutes. Regenerate it by warming to 250–300 °C, open to air through a relief cap.
Joints and seals
A system is only as good as its worst joint.
- Glass. Fuse it in the flame where you can. Ground joints and stopcocks take vacuum grease — vacuum-distilled petroleum jelly, or Ramsay's grease (raw rubber dissolved in petroleum jelly with a little paraffin wax) — in a thin, clear film; streaks mean a channel.
- Wax. Hard black wax (shellac with pitch, Tar, Pitch and Glue), melted on, for metal-to-glass joints that stay put. Good to 10⁻⁵ mm if thin and cool.
The vacuum flange
The everyday joint of metal systems. Cut a rectangular groove in one flange face, 75–80 % of the O-ring cord's thickness deep and 1.4 times it wide, so the ring is squeezed by a fifth to a quarter. Fine-turn the faces with tool marks running round, never across: one radial scratch is a leak. Wipe the ring with the barest film of grease. For small pipes use clamp flanges: two identical flat flanges with chamfered backs, a centring ring carrying the O-ring between them, and a hinged clamp that squeezes the chamfers. Fix standard bores — 16, 25 and 40 mm — once, so any part fits any other (Precision and Interchangeable Parts).
Natural rubber outgasses; nitrile rubber is better, and fluorine rubber better still and bakeable to 150 °C (Petrochemicals and Modern Plastics, Fluorspar and Fluorine Compounds). For baked and ultra-high systems, use metal seals: annealed copper rings squeezed between knife edges in steel flanges, or soft indium wire between flat faces. Pass wires through glass-to-metal seals (Scientific Glassblowing and Glass-to-Metal Seals) and shafts through two O-rings with grease between.
Materials. Good: glass, copper, steel, stainless steel, aluminium, nickel, fired ceramics. Bad: brass or zinc plating anywhere hot, porous castings, paint, most plastics, fingerprints. Weld from the inside. Vent every blind screw hole, or the air trapped behind the screw seeps out as a virtual leak.
Clean and bake. Degrease in solvent (Ether, Acetone and Solvents), wash, rinse in alcohol, dry hot, handle only with clean tissue. Bake at 150–250 °C (glass to 400 °C) for hours while pumping: a baked system reaches in an hour what an unbaked one reaches in days.
Leak hunting
- Rate of rise. Pump down, close the valve to the pumps, note the pressure each minute. A straight rising line is a leak; a rise that slows and flattens is outgassing. Leak rate = volume × rise ÷ time.
- Divide. Close valves to test sections separately.
- Gross leaks (metal only, never glass): fill with air at 0.3–0.5 bar above atmosphere and brush soapy water on every joint.
- Liquid probe. Watching a Pirani or ion gauge, dab acetone or alcohol on each joint in turn. Over a leak the reading jumps as vapour enters, or, on a fine leak, falls as the liquid plugs it.
- Light-gas probe. Blow a fine jet of hydrogen, coal gas or helium at each joint, top first. Light gases carry heat fast, so a Pirani gauge jumps when one enters.
- Spark tester on glass: run an The Induction Coil electrode over it; at a pinhole a bright white spark jumps through.
- Helium leak detector (in outline): a small mass spectrometer tuned to helium, developed for the uranium plants of the 1940s, finds leaks too small for anything else; it and the ion pump are built in Ion Pumps and Leak Detectors.
Gauges
The McLeod gauge (The Vacuum Pump) works from first principles and calibrates the rest, but it is slow and misses vapours. A working system needs gauges that read continuously.
| Gauge | Range (mm) | Notes |
|---|---|---|
| Mercury or oil column | 760 – 1 | Pressure and Vacuum Gauges |
| McLeod | 1 – 10⁻⁵ | The standard |
| Pirani or thermocouple | 10 – 10⁻³ | Rough and backing lines |
| Hot-cathode ionisation | 10⁻³ – 10⁻⁸ | The high-vacuum gauge |
| Cold-cathode (Penning) | 10⁻² – 10⁻⁷ | Rugged, no filament |
The Pirani gauge
A heated wire loses heat to the gas round it. Below about 1 mm, fewer molecules carry less heat, so the wire runs hotter and its resistance rises.
- Tube: hard glass or metal, 1.5–2 cm across, on a short wide neck.
- Wire: platinum or tungsten 0.01–0.025 mm across, 5–10 cm long, straight or in a loose zigzag between two stout leads sealed through the glass (Tungsten and Filament Wire).
- Bridge: the wire is one arm of a Wheatstone bridge on a steady few volts, so it runs at about 100–150 °C. An identical tube sealed off at high vacuum, in the next arm, cancels room-temperature changes.
- Meter: a milliammeter across the bridge, balanced at the best vacuum; it rises as pressure rises.
- Calibrate against a McLeod gauge on air at a dozen points from 1 to 0.001 mm.
Hydrogen and helium read high, oil vapour low — which makes it the leak hunter's friend. The thermocouple gauge is simpler: a heater wire on constant current with a hair-fine thermocouple welded to its middle (The Thermometer); as pressure falls, the heater runs hotter and the voltage rises.
The ionisation gauge
Electrons from a hot filament fly to a positive grid. On the way some hit gas molecules and knock electrons off them, making positive ions that a negative collector gathers. The ion current is proportional to the pressure.
- Build it like the triode of The Vacuum Tube but with a wide open neck to join the system: a tungsten filament in the middle, a spiral grid of tungsten or molybdenum wire about 1.5 cm across round it, and a nickel cylinder collector about 3 cm across outside.
- Wire it: grid +150 to +180 V and collector −20 to −30 V, both from the filament. Set the filament so the grid draws a steady 1–5 mA.
- Read the collector: for air, ion current ≈ 10 × grid current × pressure in mm. At 5 mA and 10⁻⁶ mm, that is 5 × 10⁻⁸ A — a very sensitive galvanometer or a DC amplifier (Amplifiers and Oscillators).
- Outgas the gauge when new and after each airing by heating the grid red, by current or by a few hundred volts of electron bombardment, while pumping.
Never light the filament above 10⁻³ mm: it burns out, and the gas glows. Placing the filament outside the grid and a thin collector wire inside (the Bayard–Alpert gauge) reads down to 10⁻¹⁰ mm. The Penning gauge has no filament: a high-voltage discharge held in a magnet's field, rugged but less exact.
How to tell it worked
- The rotary pump blanks off below 0.05 mm and knocks steadily.
- The hot, trapped diffusion pump takes a clean chamber below 10⁻⁵ mm within half an hour.
- A rate-of-rise test shows a curve that flattens, not a straight line.
- An induction-coil discharge tube on the system shows no glow at all (The Vacuum Pump).
Note Troubleshooting. Rotary pump stalls at a few tenths of a mm → wet oil: gas ballast open, or change the oil. Diffusion pump does nothing → backing pressure too high, heater too weak, or cooling water off. Stops at 10⁻⁴ mm → outgassing (wait, bake, fill the trap) or a small leak (rate-of-rise). Oil film in the chamber → no baffle or trap, air let in while hot, or backing pressure too high. Pirani drifts with room temperature → no compensating tube. Ion gauge jumps about → the gauge itself outgassing; degas it.
Dangers
Danger Glass under vacuum can implode. A 5-litre flask carries over a tonne of air load. Use round, thick, annealed glass, tape or net large vessels, and work behind a screen with eye protection.
Danger Liquid air or oxygen with oil explodes. Never use liquid air in a cold trap, and never leave a liquid-nitrogen trap open to the air: it condenses oxygen, which with pump oil makes an explosive mixture. Never let air into a hot oil diffusion pump; the oil can catch fire.
- Mercury vapour is poisonous; trap it, ventilate, clean up every spill (Mercury).
- Liquid nitrogen freezes skin and, boiling in a closed room, displaces oxygen (Cryogenics and Superconductors).
- Ion gauges carry hundreds of volts; rotary pump exhaust is an oil mist — pipe it outside; guard belts.
What this unlocks
Reliable valves, X-ray and Cathode Rays and Television tubes; Vacuum Coating and Thin Films; vacuum melting of Titanium; vacuum-insulated tanks for liquid gases; Lasers; Spaceflight and Spacecraft testing; and the deposition and etching machines of Making Microchips.
How it was first done
Wolfgang Gaede in Germany built a rotary mercury pump in 1905, the molecular pump in 1913 and the first diffusion pump in 1915; Irving Langmuir at General Electric improved it in 1916 into the "condensation pump" that pumped the first hard radio valves in quantity. Oil-sealed rotary pumps came into general use in the same years. C. R. Burch in England replaced mercury with carefully distilled oils in 1928, and Kenneth Hickman at Kodak made the fractionating oil pump in the 1930s. Marcello Pirani described his heated-wire gauge in 1906, Oliver Buckley at Western Electric the ionisation gauge in 1916, and Frans Penning the cold-cathode gauge in 1937. Robert Bayard and Daniel Alpert's gauge of 1950 showed that pressures far lower than anyone had been able to measure were already being reached — the start of ultra-high vacuum.
Source: content/entries/mechanics/high-vacuum.md