Power Lines and Distribution

How to carry electricity from a generator at the river to the houses and workshops of a village — why high voltage is the secret, alternating versus direct current, choosing wire, setting poles and insulators, protecting lines with fuses, earths and lightning gaps, and laying out a small village grid.

Difficulty
●●●●●
Time
A few weeks to plan and set poles for a village line; transformers and insulators must be made first
Steps from zero
25 prerequisites →

You need first

The TransformerWiring and Electrical Safety

This unlocks

Electricity Meters and Billing
The full path from nothing — 25 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Hunting and Trapping
  7. Basic Woodworking
  8. Charcoal
  9. Pottery
  10. Hides and Leather
  11. Fermentation
  12. The Wheel and Axle
  13. Bellows
  14. Gears
  15. Copper Smelting
  16. Iron (the Bloomery)
  17. The Waterwheel
  18. Blacksmithing
  19. The Battery
  20. Magnets
  21. Copper Wire
  22. The Electromagnet
  23. The Generator
  24. The Transformer
  25. Wiring and Electrical Safety
  26. Power Lines and Distribution

Do them roughly in this order. See it on the tech tree →

Why it matters

Power is rarely made where it is used. The best waterfall is up a valley; the best wind is on a bare hill; a steam plant wants to be by the coal or the river. Without wires, every user must sit beside the machine. With wires, one well-built Water Turbines and Hydroelectric Power or The Steam Turbine can light a whole village, run a The Lathe in one workshop, an The Electric Motor in another, and a pump at the well (Pumps) — each switching on and off as needed.

A shared supply also uses machines far better. Households want light in the evening; workshops want power by day; a sharing grid fills one demand with the other. And the people who build and run the generating plant can be a few skilled specialists instead of every household needing its own.

This chapter is about getting power from the plant to the user safely and without losing most of it on the way. It builds on The Transformer (how to change voltage) and Wiring and Electrical Safety (how to wire a building).

How it works

Why wires lose power

Every wire has resistance — it resists the flow of current, and turns some of the power passing through it into heat. Two rules decide how much:

  • Voltage drop in a wire = current × resistance. The more current, the more voltage is lost along the way.
  • Power lost in a wire = current × current × resistance. Double the current, four times the loss.

The power you are sending is voltage × current. So to send the same power with less current, raise the voltage. Ten times the voltage means a tenth of the current, and a hundredth of the loss. This single fact is the reason for every tall power line in the world.

Example: sending 5 kW to a village 1 km away, on two copper wires each 4 mm² in cross-section (about 2.3 mm thick):

Sent at Current Voltage lost on the line Power lost
230 V 22 A 190 V — almost all of it most of it: the lamps barely glow
2,300 V 2.2 A 19 V (less than 1%) about 40 W

Working out a wire size

For two copper wires (out and back), with the length measured one way:

Volts lost ≈ 0.035 × length (m) × current (A) ÷ wire area (mm²)

Keep the loss to 5% or less of the supply voltage for lighting. Wire area in mm² = 0.785 × diameter² (diameter in mm). Common sizes: 1.5 mm² (1.4 mm thick), 2.5 mm² (1.8 mm), 4 mm² (2.3 mm), 10 mm² (3.6 mm), 16 mm² (4.5 mm), 25 mm² (5.6 mm).

Iron and steel wire conduct about 6 to 10 times worse than copper, but they are much stronger and far easier to make (Iron (the Bloomery), Steel). At low voltage they are nearly useless for power; at high voltage, where the current is small, iron wire often does the job well. Early telegraph lines (The Telegraph) were iron for this reason. Twisting a few copper strands around a steel core gives both strength and conductivity.

AC or DC?

A The Transformer changes voltage — up to send, down to use — but it works only with alternating current (AC). That decides most of the argument.

Direct current (DC) Alternating current (AC)
Change voltage Hard (needs a motor-generator) Easy, with a transformer
Practical distance at house voltage A few hundred metres Many kilometres at high voltage
Store in batteries Directly Must be converted (rectified)
Generator Commutator, brushes, sparks Simpler; no commutator
Speed control Voltage depends on speed only Speed sets the frequency too — must be steady

The choice for a small community:

  • Under about 200 m, a few kilowatts, with batteries (a wind or solar charger serving a cluster of houses): low-voltage DC, 24–110 V.
  • A single settlement within 1 km of the plant: AC at house voltage (110–240 V) straight from the generator, with thick wire.
  • Anything farther, or bigger: AC, stepped up at the plant to 2,000–11,000 V and stepped down again near the users. This is the plan the rest of this chapter follows.

Frequency. An AC generator's frequency is set by its speed: a machine with 4 magnetic poles turning 1,500 times a minute gives 50 cycles a second (50 Hz); at 1,800 turns, 60 Hz. Pick one frequency for the whole community and keep it: transformers and motors are built for it. Hold the speed within a few percent with a governor (Governors and Speed Control) or ballast load (Water Turbines and Hydroelectric Power).

Three-phase — three sets of coils in the generator and three line wires — sends more power for the same copper and lets motors start themselves. It is the standard for big grids. For a first village, single-phase (two wires) is simpler; plan the generator so you can change later.

What you need

Item Notes
Generator AC alternator with steady speed, or a dynamo for DC (The Generator)
Step-up and step-down transformers See The Transformer. Iron core, oil- or air-cooled, housed and earthed
Line wire Copper (hard-drawn for strength) or galvanised iron/steel; see Copper Wire
Poles 8–10 m, straight, 15 cm thick at the top; rot-resistant wood or treated softwood
Crossarms Hardwood, 10 × 8 cm, 1–1.5 m long
Insulators Glazed porcelain or glass, with pins of iron or oiled hardwood
Guy wires and anchors At bends and line ends
Earth rods Iron or copper, 1.5–2 m long
Fuses, switches, lightning gaps Porcelain or slate bases; fuse wire of lead or tin
Tools Pole-hole digger (a long narrow spade and a bar), block and tackle, wire tensioner (a ratchet or a lever with a clamp), climbing irons or ladders, rope

Where to find it

  • Poles. Tall, straight conifers — pine, larch, spruce, fir, cedar — from a managed woodland (Firewood and Coppicing). Larch, cedar and chestnut heartwood rot slowly; others must be treated. Fell in winter, peel the bark at once, and dry the poles for several months.
  • Wood preservative. Coal tar creosote or wood tar (Tar, Pitch and Glue) worked hot into the butt end, or charring the part that goes into the ground until it is black and crusted, then tarring it.
  • Insulators are made like fine pottery from kaolin (white china clay), feldspar and quartz, fired hard enough to become glassy right through, and glazed — see Stoneware and Porcelain. Glass insulators (Glass) cast in a mould also work well. Seasoned oak or locust boiled in linseed oil served for low-voltage pins and as a stop-gap insulator.

Step by step: a village mini-grid

1. Plan the loads

Walk the village. List every house, workshop and public building and what each will use:

Use Typical power
One carbon-filament lamp (The Light Bulb) 30–60 W
A household's evening lights 100–200 W
A workshop motor (The Electric Motor) 0.5–3 kW
A water pump 0.5–2 kW
A small electric forge or kiln 3–10 kW

Add up the largest amount that might be on at the same time — usually the evening lighting peak. That figure, plus about 20%, is the size of generator and transformers you need. If the plant cannot supply it, give each house a fixed allowance enforced by a fuse (for example 1 A at 230 V — about 200 W), and run big loads like forges by day.

2. Lay out the route

Generator230 V, steady speed Step-up1 : 10 High-voltage line, 2,300 V10 kW is only 4.4 A: thin copperor iron wire will do 1.5 km — poles every 50–80 m lightning gap Step-down10 : 1 Feeders230 V, up to 300 m each fuse Earthrod Earthed neutralat the transformer
Fig. 1 A small village grid. The generator's voltage is stepped up for the long line to the village and stepped down again at a transformer in the middle of the houses; short low-voltage feeders then run out to each building, each house protected by its own fuse and earth.
  1. Put the step-down transformer in the middle of the houses, not at the edge. The low-voltage wires then stay short — no more than about 300 m in any direction.
  2. Run the high-voltage line as straight as possible from the plant to the transformer, along tracks and field edges where you can reach it, avoiding trees, cliffs and floodplains.
  3. Mark pole positions every 40–50 m for low-voltage lines and 50–80 m for high-voltage lines with strong wire. Put an extra pole at every change of direction greater than about 10°.

3. Size the wires

Worked example: 10 kW from a plant 1.5 km from the village, generated at 230 V.

  1. The long line. Step up 1:10 to 2,300 V. Current = 10,000 ÷ 2,300 ≈ 4.4 A. With 10 mm² copper: drop ≈ 0.035 × 1,500 × 4.4 ÷ 10 ≈ 23 V (1%). Even 4 mm galvanised iron wire (about 12.5 mm², but 6 times the resistance of copper) loses only about 4–5% — perfectly usable.
  2. The feeders. Step down 10:1 to 230 V near the village centre. Split the village into 3–4 feeders, each carrying no more than about 15 A. For a feeder 300 m long carrying 15 A and losing no more than 11 V (5%): area ≥ 0.035 × 300 × 15 ÷ 11 ≈ 14 mm² — use 16 mm². Shorter feeders can be thinner.
  3. House connections (a few tens of metres, under 2 A): 2.5 mm² is plenty.

4. Set the poles

ONE SPAN, SIDE VIEW 40–50 m (low voltage) sag 1.5–2%of the span 5.5 mor moreover tracks 1/10 of length + 60 cm Guystrain insulatorabove head height POLE TOP, LOOKING ALONG THE LINE Pin insulatorglazed porcelain;the skirt keeps rainoff part of it Iron brace Earth wireat transformersand line ends Hardwoodcrossarm, boltedinto a notch 30–40 cm; 60–90 cm high voltage
Fig. 2 The top of a line pole and the parts that matter: crossarm, insulators with skirts to keep rain from bridging them, wire ties, a guy with its own insulator, an earth wire, and how deep and how high everything sits.
  1. Treat the butts. Char and tar the bottom 2 m of each pole. Cut the top on a slant (or cap it with a board or sheet metal) to shed rain.
  2. Fit crossarms before raising: a hardwood arm let into a notch (a gain) cut 2.5 cm deep in the pole, 20–30 cm below the top, held with a through-bolt and two diagonal iron braces. Drill holes for the insulator pins: about 30–40 cm apart for low voltage, 60–90 cm apart for 2,000–11,000 V, so that wires blowing in the wind never touch.
  3. Dig the hole to a depth of one-tenth of the pole's length plus 60 cm — 1.5 m for a 9 m pole — in firm soil; deeper in soft ground.
  4. Raise the pole with a team: lever the top end up on a pair of crossed poles (pikes) or a gin pole with block and tackle, while the butt drops into the hole against a board that stops it digging into the far side. Plumb it by eye from two directions at right angles.
  5. Backfill in layers of 15 cm, ramming each hard with a heavy bar. Put stones in the fill near the top and bottom of the hole.
  6. Guy every pole at a bend, at both ends of the line, and on every fifth pole on a long straight line. Run iron wire from near the top of the pole to an anchor — a log or stone slab buried 1.2–1.5 m deep across the line of pull — set as far out as the height of the attachment if you can, and at least half of it. Put a strain insulator (a porcelain egg with the wires looped through it crosswise) in each guy, at least 2.5 m above the ground, so that if a line wire falls on the guy, the lower part stays dead.

5. Hang the wire

  1. Insulators screw or cement onto iron or oiled hardwood pins in the crossarm. Choose them for the voltage: small spool insulators for house voltage; pin insulators with one or more downward skirts ("petticoats") for higher voltage. The skirts keep part of the surface dry in rain, lengthening the wet path from wire to pin. Allow at least 2–3 cm of surface path per 1,000 V, more near the sea or smoky towns.
  2. Pay out the wire from a turning drum, never pulled off a stationary coil (which kinks it). Lay it along the ground beside the poles, lift it into place, and pull it tight at one end with a tensioner against a guyed end pole.
  3. Sag. Do not pull it bar-tight. Copper and iron shrink in frost; a tight wire snaps on the first cold night, or under ice and wind. Aim for a sag at the middle of each span of about 1.5–2% of the span in mild weather: 60–80 cm on a 40 m span. Sight it by eye against a mark on the poles.
  4. Clearance. The lowest point of the lowest wire must stay at least 5.5 m above any track used by carts or riders, 5 m above fields, and higher for high-voltage lines (7 m or more). Keep 3 m sideways clear of trees and buildings for low voltage, more for high voltage.
  5. Tie each wire to its insulator with soft wire of the same metal (copper on copper), wrapped tightly round the wire and the insulator's groove. Mixing copper and iron where they touch in wet air makes them corrode.
  6. Join wires with long, tight twisted joints (a "Western Union" splice), soldered if possible (Soldering and Brazing); a loose joint gets hot and burns through.

6. Protect it

  • Fuses. A fuse is a short, thin piece of wire (lead, tin, or a lead-tin alloy) in a holder on a porcelain or slate base. Too much current melts it and breaks the circuit before the line or anything on it overheats. Put one at the generator, on each side of each transformer, at the start of each feeder, and at each house. Calibrate your fuse wire: find by trial the thickness that holds its rated current for an hour but melts within a minute or two at twice that.
  • Switches. A knife switch on each feeder and at each transformer lets you make a section dead for work. Make sure it can be locked open.
  • Earthing. Drive an iron or copper rod 1.5–2 m into moist ground (or bury a plate in a pit of charcoal and damp soil) and connect it with a thick wire to: one side of every low-voltage circuit at the transformer (the neutral); the transformer's iron case; the metal frames of motors and machines; and each house's earth terminal. If a live wire then touches a casing, a big current flows to earth and blows the fuse instead of waiting for a person to touch it. See Wiring and Electrical Safety.
  • Lightning. A lightning strike on or near a line sends a huge surge along it. At the plant, at each transformer and at the far ends of the line, fit a lightning gap: two thick iron horns, one joined to the line, one to an earth rod, their tips a few millimetres apart (wider for higher voltages). Normal voltage cannot cross the gap; a lightning surge jumps across to earth instead of through the transformer. The horns are bent upward and apart so the arc climbs and stretches until it breaks.

7. Run it

  • Switch on feeders one at a time, watching the generator; switch off in the reverse order.
  • Walk the line every few weeks: leaning poles, broken insulators, wires touching branches, loose guys.
  • Metering. The simplest is a fixed fuse allowance per house. Thomas Edison's first customers paid by an electrolytic meter: a small part of their current passed through a jar of zinc sulfate between two zinc plates, carrying zinc from one plate to the other (Electrolysis). Each month the plates were weighed; the weight of zinc moved showed how much electricity had been used. It works only on DC; AC meters are small motors that count turns (Electricity Meters and Billing).

How to tell it worked

  • Voltage at the far end. With all lamps on, carbon lamps at the farthest house should glow as brightly as those beside the transformer. Dull lamps at the end of a feeder mean too much drop: thicker wire or a shorter feeder.
  • Warm joints. After an evening of full load, feel every joint and fuse holder (with the section switched off and earthed). Any that is warm is loose or too thin.
  • No humming, crackling or blue glow at insulators on a damp night. A faint crackle and glow at high-voltage insulators means leakage — clean them, or fit ones with longer skirts.
  • Insulator test. Before use, break one insulator from each kiln firing and dab ink on the broken face: if it soaks in, the porcelain is not fully fired and will soak up rain. Test good ones at twice their working voltage between wire groove and pin, wet.

Note Troubleshooting. Fuses blow every evening → the load is bigger than planned; enforce allowances, or add a second feeder. Lamps flicker in wind → wires swinging together or a loose joint; increase spacing, tighten joints. Lamps dim slowly over months → corroded joints or a failing transformer; check joints first. Lights dim when the sawmill starts → large motor on the same feeder. Give big motors their own feeder, or start them slowly. Shock from a machine casing or tap → missing or broken earth, or an earth rod in dry ground. Switch off and find it at once. Insulators crack in frost → porous porcelain; fire hotter and glaze better.

Dangers

Danger High-voltage lines kill instantly and without warning. At 2,000 V and above, current can jump through the air to a hand, a ladder or a wet rope before you touch the wire. Never touch, climb near, or work on a line unless it is switched off, locked off, tested dead and earthed on both sides of you — earthed by clamping a thick wire from each line wire to an earth rod, so that if someone switches it on by mistake, the current goes to earth, not through you. A line can be made live again by a forgotten generator, a transformer fed from the other side, or lightning.

Danger A fallen wire may still be live, and so may the ground around it for several metres: the voltage spreads out through the soil, and a person walking with long strides can get a shock from foot to foot. Keep everyone at least 18 m away (about 20 paces), further on wet ground. If you find yourself close, shuffle away with tiny steps, feet together. Never touch a person in contact with a wire with your hands; switch off the line first. Only on a low-voltage line that you truly cannot switch off, push them clear with a long, dry wooden pole. Dry wood is no protection at high voltage: if the wire is a high-voltage line, stay 10 m back, keep others back, and wait until it has been switched off and earthed.

  • Falling poles crush. Never stand on the side where a pole would fall during raising; never climb a pole without checking its base for rot.
  • Ladders, long poles, kites and fishing rods near power lines kill people every year. Teach everyone where the lines run.
  • Fire. Overloaded or loose connections inside houses start fires. Fuse everything; never replace a blown fuse with a thicker wire or a nail.
  • Transformer oil can catch fire if the transformer overheats. Keep transformers away from buildings and combustibles.

Going further

  • Linking plants. Two or more AC generators can share one grid if they run at exactly the same frequency and in step (synchronised). The old way: connect a lamp across each pole of the switch between them; when the machines are in step the lamps go dark, slowly pulsing; close the switch at the moment of darkness (see Synchronous Motors and Converters). Done wrongly, the generators fight each other and can be wrecked.
  • Longer lines at 10,000–30,000 V and more need taller poles, chains of suspension insulators hanging below the crossarm, and steel towers (Steel Frames and Tall Buildings).
  • Underground cables in towns need insulation that stays dry for decades: rubber (Rubber), oiled paper and lead sheathing (Lead).
  • Grids carry signals too: see The Telephone and Networks and the Internet. A grid with several plants and unmanned substations is watched and switched from one control room by Telemetry and Remote Control.

How it was first done

In 1881 the small English town of Godalming got one of the first public electricity supplies, from a waterwheel-driven generator. In 1882 Thomas Edison's Pearl Street station in New York began supplying direct current at 110 V to about 60 customers; its copper wires were laid underground and, because of losses at such a low voltage, could reach customers only within about 1.5 km of the station. In 1883–84 Lucien Gaulard and John Gibbs demonstrated transformers on an AC line near Turin, Italy, and in 1885 Károly Zipernowsky, Ottó Bláthy and Miksa Déri at the Ganz works in Budapest built the closed-iron-core transformer still used today. In 1886 William Stanley, working for George Westinghouse, lit the town of Great Barrington, Massachusetts, with stepped-down AC.

The bitter "war of the currents" between Edison's DC and Westinghouse's AC (using Nikola Tesla's AC motor patents) was settled by distance. In 1889–91 Sebastian de Ferranti built the Deptford station in London to send power at 10,000 V. In 1891 a three-phase line carried power 175 km from Lauffen to the electrical exhibition in Frankfurt, Germany, at up to 25,000 V, with about three-quarters of the power arriving. In 1896 AC from Niagara Falls reached Buffalo at 11,000 V, and the design of the modern grid was fixed.