◆ Rebuild

Part 14 · Electronics and Computing

Thermostats and Automatic Control

A thermostat holds a temperature steady by itself, day and night, so nobody has to sit by the incubator, oven or kiln. How to make bimetal strips, mercury switches, contact thermometers and liquid-filled capsules, how to wire them to relays and heaters, the difference between on–off and proportional control, and how to control incubators, ovens, kilns and crystal ovens safely.

Difficulty
●●●●●
Time
A day to make a bimetal thermostat; a week to tune an incubator or kiln controller
Steps from zero
25 prerequisites →

You need first

The ThermometerThe Electromagnet

This unlocks

Instruments, Chart Recorders and Control RoomsProcess Controllers and Control ValvesRobots and Automation

Raw materials

cinnabar
The full path from nothing — 25 steps before this one
  1. Fire
  2. Cordage and Rope
  3. Stone Tools
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Measurement from Scratch
  7. Hunting and Trapping
  8. Basic Woodworking
  9. The Kiln
  10. Pottery
  11. Charcoal
  12. Hides and Leather
  13. Lime
  14. Lye and Potash
  15. Fermentation
  16. Glass
  17. Bellows
  18. Copper Smelting
  19. Iron (the Bloomery)
  20. Laboratory Glassware
  21. Blacksmithing
  22. The Battery
  23. The Thermometer
  24. Copper Wire
  25. The Electromagnet
  26. Thermostats and Automatic Control

Do them roughly in this order. See it on the tech tree →

Why it matters

Many processes need a temperature held steady for hours or weeks: eggs hatching at 37.5 °C for 21 days (Poultry and Eggs), bacterial cultures at 37 °C (Culturing Microbes, Penicillin), bread rising, yoghurt and cheese (Dairy and Cheese), an oven baking evenly, a kiln held at its top heat (The Kiln), a water tank kept hot but not boiling (Hot Water and Central Heating), a quartz crystal that must not drift (Quartz Crystals and Frequency Control). Without automatic control someone must watch a thermometer and adjust a fire or a lamp, every hour, all night. A thermostat does it alone.

It is also the clearest example of feedback — measure, compare, correct — the idea behind the governor, the autopilot and every automatic machine that follows.

How it works

Every controller has three parts:

  1. A sensor that responds to temperature: a strip that bends, a liquid that expands, a vapour whose pressure rises, a resistance that changes (thermistor) or a thermocouple voltage.
  2. A set point — the temperature you want — usually an adjusting screw.
  3. An actuator that changes the heat: a contact that switches a heater, a relay (The Electromagnet), a damper over a lamp chimney, or a gas or oil valve.

On–off control

The simplest controller switches full heat on below the set point and off above it. Two things spoil it:

  • The differential. A contact that opens and closes at exactly one temperature chatters on and off many times a second, sparks and burns away. Every on–off thermostat therefore switches on a little below the set point and off a little above it. That gap — the differential or hysteresis — is typically 0.5–2 °C for an incubator and 5–15 °C for an oven. A snap action (a magnet that pulls the contact the last bit of the way, or a spring-over-centre) gives a clean, fixed differential.
  • Lag and overshoot. Heat takes time to travel from heater to sensor. When the thermostat switches off, the heater is still hot and keeps pouring heat in, so the temperature overshoots. When it switches on, the heater takes time to warm, so it undershoots. The swing is always wider than the differential. Cure it by putting the sensor close to the thing you care about (the eggs, the crystal), using a heater no bigger than needed (about twice the power it takes to hold temperature), and stirring the air with a fan.

Proportional control

A better controller gives some heat — more the colder it is, less as it nears the set point. A furnace damper half open, a gas valve partly closed, or a heater switched on for a fraction of every minute (time-proportioning) settles at a steady level instead of swinging. The range of temperature over which the power goes from full to nothing is the proportional band. A narrow band holds closely but may start to swing, a wide one holds steadily but settles slightly below the set point (the offset or droop, exactly as with a governor). Advanced controllers add a slow correction that removes the offset and a fast one that anticipates change; these three terms (proportional, integral, derivative) are called PID. For most work in a rebuilding community, on–off with a small differential or simple proportional control is enough.

overshoot warmer cooler set point time differential band on–off: overshoots, then swings proportional: settles, a little low Heater, on–off Heater, proportional
Fig. 1 On–off and proportional control. With on–off control the heater runs flat out until the temperature passes the upper switch point, then overshoots and swings. With proportional control the power eases off as the set point nears, and the temperature settles.

What you need

Item Use See
Brass, iron or steel, invar strip 0.3–1 mm Bimetal strips Zinc and Brass, Alloy and Stainless Steels
Silver or platinum Contact tips Gold and Silver
Fine-threaded brass screws (M3–M4) Set point adjustment Screws, Nuts and Bolts
Glass tube, mercury, platinum wire Mercury switches and contact thermometers Laboratory Glassware, Mercury, The Thermometer
Thin brass or German silver sheet 0.1–0.2 mm, ether or alcohol Capsule thermostats Sheet Metal and Rolling, Ether, Acetone and Solvents
Relays, wire, insulated heater wire Switching heaters The Electromagnet, Nickel and Cobalt
Mica, porcelain Insulators near heat Building Circuits: Boards, Connectors and Cables

Where to find it

Everything here is made in other chapters. Mercury is roasted from bright red cinnabar (Mercury). Invar — iron with 36% nickel — barely expands at all and makes the best partner for brass in a bimetal (Alloy and Stainless Steels). Silver for contacts comes from Gold and Silver; silver tips do not weld or burn as copper does.

The bimetal strip

Two metals that expand by different amounts, bonded together along their whole length, must bend when heated: the one that grows more ends up on the outside of the curve. This is the commonest temperature sensor in the world.

How much they expand, in millionths of their length per degree:

Metal Expansion
Zinc 30
Brass 19
Copper 17
Iron, mild steel 12
Invar (36% nickel iron) about 1.5

How far it bends. For two equal layers, the free end of a straight strip moves by about

movement ≈ 0.75 × (difference in expansion) × (temperature change) × length² ÷ thickness.

A brass–steel strip 100 mm long and 1 mm thick (two 0.5 mm layers) moves about 0.5 mm for every 10 °C. Brass–invar moves about twice as far. Halving the thickness doubles the movement but halves the force. Coiling a long strip into a flat spiral or helix packs a great length into a small space: the centre turns, and a pointer on it makes a dial thermometer.

Making it:

  1. Cut two strips of the same size, for example 10 mm wide and 120 mm long, one of brass, one of iron, steel or invar, each 0.3–0.5 mm thick. Flatten them on an anvil and clean the faces bright.
  2. Bond them along the whole length. Best: braze them with silver solder or brass spelter, clamped flat between iron bars, in a clear fire (Soldering and Brazing). Next best: rivet them with small copper rivets every 10–15 mm. Soft solder works for a strip that never goes above about 120 °C.
  3. Anneal and settle. Heat the finished strip a little above its highest working temperature and let it cool slowly, three or four times. A new strip creeps and shifts its setting for the first few cycles; settling gets that over with.
  4. Mark it. Stamp or scratch "B" on the brass side. The strip bends away from the brass when it warms.

A good strip is flat and straight when cold, bends evenly along its length when warmed in hot water, and comes back to exactly the same place when cold again. A bad one has an unbonded patch (it bends in a kink) or creeps (its cold position moves day by day).

The bimetal thermostat

Bimetal strip steel on top, brass below warm: bends up, opens battery, a few volts relay silver contacts Fixed end clamped in a bracket Snap magnet gives a clean switch Adjusting screw sets the temperature heater supply heater
Fig. 2 The bimetal thermostat. A brass–steel strip, fixed at one end, carries a silver contact at its free end. When cool, it touches the adjusting screw and the relay pulls in to run the heater. As it warms, it bends away and the circuit breaks. Turning the screw sets the temperature. A small magnet gives a snap action.
  1. Base. A block of slate, porcelain or hard dry wood, about 15 × 5 cm.
  2. Strip. Clamp one end of a bimetal strip (100–150 mm long) firmly under a brass bracket, brass side facing the contact screw, so that warming bends the strip away from the screw (the strip always bends away from its brass side).
  3. Contact. Rivet or solder a small silver button to the free end of the strip. Opposite it, mount a brass pillar with a fine-threaded adjusting screw, also tipped with silver. A screw with 0.5–0.7 mm pitch moves the contact about 0.5 mm per turn: roughly 10 °C per turn for the strip above.
  4. Snap action. Fix a small permanent magnet (Magnets) beside the screw so that it pulls the strip (by its iron or steel layer) the last half-millimetre onto the contact. The strip now leaves the contact suddenly, and returns suddenly, instead of creeping. This sets a clean differential of about 1 °C.
  5. Wire it to a relay. Never switch a heater of more than a few watts through the bimetal contact itself; it will arc and burn. Run a small current (a few volts and under 0.1 A) through the contact to work a relay, and let the relay's heavy contacts switch the heater. Put a 0.1 µF capacitor in series with 100 Ω across the thermostat contact to soak up the spark.
  6. Set it. Put the whole thermostat in the incubator or oven beside a good The Thermometer. Screw the contact in until the heater comes on, wait for it to settle, and adjust a quarter-turn at a time until it switches off at the temperature you want.

Rod-and-tube thermostat. For ovens and water heaters, use a brass tube with an invar or porcelain rod inside it, joined at the far end. The tube grows when heated; the rod hardly does, so the free end of the rod moves back relative to the tube and opens a contact or closes a gas valve. A 30 cm brass tube moves about 0.5 mm per 100 °C relative to invar — small, but with great force, enough to work a valve directly. This is the classic oven and water-heater thermostat (Electric Kettles, Irons, Heaters and Cookers).

Energy regulator. A cooker hot-plate control that gives a set fraction of full power: a bimetal strip carries its own small heater wire, in series with the main element. When the contact is closed, the little heater warms the strip until it opens; it cools and closes again. The adjusting knob sets how long it stays closed in each cycle, from a few per cent to nearly all the time. It is the simplest time-proportioning controller.

Mercury switches and contact thermometers

The mercury switch. Seal two platinum or iron wires through one end of a short glass tube, 8–10 mm across and 3–5 cm long, and put in a drop of mercury about the size of a pea. Fill with dry hydrogen or nitrogen, or evacuate it (The Vacuum Pump), and seal it. Tilted one way, the mercury bridges the wires; tilted the other, it runs away. Mounted on the end of a coiled bimetal strip, it makes a thermostat with a perfectly clean, unburnable contact that switches up to a few amperes. It needs to be mounted level and kept still.

The contact thermometer. The most accurate simple controller. Make a mercury The Thermometer with a platinum wire sealed through the bulb and a second fine platinum wire sealed through the stem at the exact height of the set temperature. When the mercury reaches the upper wire, the circuit closes. It holds a temperature to ±0.1 °C or better — good enough for crystal ovens and laboratory baths.

  • The current must be tiny: under 10–20 mA, at under 6 V. A spark in the capillary dirties the mercury and the contact fails. Let it drive a sensitive relay, or the grid of a tube or base of a transistor that works the relay (Amplifiers and Oscillators).
  • An adjustable version has the upper wire on a fine screw inside the stem, turned from outside by a magnet.

The capsule thermostat (no electricity)

Where there is no electricity, a sealed capsule can work a damper directly. This is how oil-lamp incubators held 38 °C for weeks in the late 1800s.

Capsule ether and alcohol; swells when warm Rod Pivot sliding weight sets the temperature Damper lifts to let heat escape Lamp escaping heat Eggs on the tray Heater flue warms the box
Fig. 3 The capsule regulator on an oil-lamp incubator. A sealed brass capsule holding a few drops of ether and alcohol sits among the eggs. Warmth makes the liquid boil and the capsule swells; it pushes up a rod, which tips the lever and lifts the damper off the lamp chimney, so the hot air escapes outside instead of warming the box.
  1. The capsule. Cut two discs 5–6 cm across from thin brass or German silver, 0.1–0.2 mm thick. Press a few shallow concentric rings into each on a hardwood former so they flex easily. Soft-solder them together round the edge, with a fine brass tube let into one face.
  2. Fill it with a few drops of a liquid that boils a little below the working temperature. Ether alone boils at about 35 °C; mixing in alcohol raises that. Add a little at a time, sealing temporarily, and test in a water bath with a good thermometer: the capsule should be flat at 37 °C and swell firmly by 39 °C. When right, pinch the tube shut and solder it.
  3. The linkage. Stand the capsule on the floor of the egg chamber. A light rod from its top passes up through the lid to a balanced lever about 40–50 cm long, pivoted near the rod. The long end carries a flat metal damper resting on the top of the lamp's heater flue. A sliding weight on the lever sets the temperature.
  4. How it acts. When the box is too warm, the capsule swells, the lever tips, and the damper lifts: hot air escapes from the flue instead of passing through the heater. As the box cools, the capsule shrinks and the damper drops back. The control is smooth and roughly proportional.

A wax-filled capsule works the same way: some waxes expand by about a tenth as they melt, with great force, over a narrow range of temperature. A brass cup of wax with a rubber plug and a pin makes a wax motor that opens a valve or vent at a chosen temperature — this is the thermostat in a car's cooling system and a greenhouse vent opener (Cold Frames, Cloches and Greenhouses).

Controlling real things

Incubators

  • Heater: a lamp, a carbon-filament bulb or a coil of resistance wire, sized at about twice the power needed to hold temperature; for a 50-egg box, 25–40 W.
  • Sensor at egg height, in the moving air, not next to the heater.
  • Set: 37.5 °C with a fan, 38.5 °C at egg-top height in still air (Poultry and Eggs); 37 °C for most bacterial cultures.
  • Differential: 0.5 °C or less. A bimetal with snap magnet, a mercury switch on a coiled bimetal, or a capsule all do this well.
  • Safety: a second thermostat set at 39.5 °C, wired to cut the heater if the first sticks closed.

Ovens

A rod-and-tube thermostat on the gas or oil valve, or a bimetal working a relay on electric elements, set between 100 and 250 °C. A differential of 5–10 °C is fine; the oven's walls even out the swing. A good oven thermostat holds the middle of the oven within 10 °C of the dial.

Kilns

Bimetals, wax and mercury all fail above a few hundred degrees. Use:

  • A thermocouple controller. A thermocouple drives a millivoltmeter with a light pointer. Fit an adjustable stop or contact at the set point. To avoid putting any force on the delicate pointer, a motor-driven chopper bar drops every few seconds and presses the pointer lightly down: if the pointer is past the set point, it closes a contact that opens the heating relay. Set the controller to switch off at the top temperature, or step the set point up by hand through a firing schedule.
  • A cone-operated cut-off (kiln sitter). A small pyrometric cone or bar (The Kiln) lies across two supports inside the kiln, with a rod resting on it that passes out through the wall. When the cone softens and bends at its rated temperature, the rod drops, releasing a weight that trips the main switch. It shuts off the kiln at the right heat-work (time and temperature together), which is what the ware actually feels.
  • Fuel-fired kilns are controlled by hand with dampers and air, guided by thermocouples and cones. Automating a fuel kiln is possible with a thermocouple controller working a motorised damper, but must have a reliable flame-failure valve (Thermocouples and Thermoelectricity) on any gas burner.

Crystal ovens

A quartz crystal is held at 50–75 °C, above any room temperature, so the oven only ever has to heat (Quartz Crystals and Frequency Control). Put the crystal in a thick copper box (it smooths out the temperature), the heater wound round the box, the sensor inside, and the whole lot in a felt-lined wooden case. A contact thermometer holds it to ±0.1 °C; a thermistor bridge driving a tube or transistor proportionally to the heater does better still.

Thermal cut-outs

Every thermostat can fail stuck closed — a welded contact, a broken strip, a stuck relay. Every heated thing needs an independent cut-out that cannot reset itself:

  • A thermal fuse: a short link of low-melting alloy (tin, lead and bismuth, melting at 70–150 °C depending on the mix; see Antimony and Bismuth) held under spring tension in series with the heater, in contact with the hot part. When it melts, the spring pulls the circuit apart. It must be replaced by hand.
  • A second bimetal, set 5–20 °C above the working thermostat, wired to open the supply and stay open until someone presses a reset button.

How to tell it worked

  • Set it overnight with a The Thermometer at the sensor's position and another at the far side. Read them every hour for the first evening. A good incubator controller holds within ±0.5 °C; a good oven within ±10 °C.
  • Count the cycles. A thermostat that clicks every 10–30 seconds has too small a differential or too big a heater; every 5–20 minutes is about right for an incubator.
  • Open the door for a minute: the heater should come on promptly and the temperature recover without overshooting by more than a degree or so.
  • Test the cut-out by holding the main contact closed: the cut-out must open before anything is damaged.

Note Troubleshooting. Wide swings, far above and below the set point → sensor too far from the load or too close to the heater; heater too powerful; no air movement. Contact chatters and buzzes → no snap action; fit the magnet, or use a mercury switch. Contacts blackened and sticky → switching the heater directly; use a relay and a spark-quench capacitor. Setting creeps over days → bimetal not settled; cycle it hot and cold several times. Or the base is wooden and moving with damp. Contact thermometer stops switching → current too high and the mercury is fouled; reduce the current to a few milliamps. Capsule no longer moves → it has leaked; refill and resolder.

Dangers

Danger A stuck thermostat starts fires. A contact welded shut keeps a heater running until the oven, incubator or building burns. Every heater needs an independent thermal cut-out, a fuse rated for the heater, and a fireproof place to stand. See Wiring and Electrical Safety and Firefighting.

  • Mercury. Spilled mercury gives off invisible poisonous vapour, worst in warm rooms — and thermostats live in warm places. Use glass that will not break, enclose mercury switches, and collect spills with a card and a sheet of copper, never a brush or vacuum. See Mercury.
  • Ether is extremely flammable, its vapour heavier than air, and it can be lit by a hot surface. Fill capsules outdoors, far from flames.
  • Mains in damp places. Incubators and greenhouses are humid. Run thermostat circuits at low voltage through a relay, earth all metal, and keep mains wiring sealed.
  • Kilns and their controllers: see The Kiln.

What this unlocks

Thermostats turn heat into a dependable tool: incubators for chicks and microbe cultures, steady ovens for bread and Penicillin work, safe Electric Kettles, Irons, Heaters and Cookers and water heaters, refrigerators that switch their compressor on and off, crystal ovens for accurate clocks and radios, and controlled The Kiln firings. The same idea — sense, compare, correct — controls pressure, level (Photocells and Sensors) and speed (Governors and Speed Control), and leads to the automatic factory (Process Controllers and Control Valves) and the The Computer in charge of it.

How it was first done

The Dutch inventor Cornelis Drebbel built an incubator and furnace regulator in the early 1600s: a glass vessel of alcohol and mercury that expanded with heat and pushed up a rod that closed a damper. In the 1750s John Harrison used a bimetallic strip of brass and steel to correct his marine chronometers for temperature (Chronometers and Stopwatches). The Scottish chemist Andrew Ure patented a bimetal regulator and coined the word "thermostat" in 1830. In the 1880s Charles Hearson in London sold incubators controlled by an ether-filled capsule, and in 1883 Warren Johnson in the United States patented an electric room thermostat; his company went on to work the dampers of whole buildings by compressed air. Charles-Édouard Guillaume discovered invar in 1896, which gave bimetals their best partner. The mathematics of PID control came from Nicolas Minorsky's work on automatic ship steering in 1922.

Source: content/entries/electronics/thermostats.md