Part 6 · Building
Water and Gas Meters
How to measure the water and gas each house and factory uses. Positive-displacement meters fill and empty a chamber of known size and count the fillings; the rotary piston water meter and the bellows gas meter are the household kinds, the wet drum meter the simplest. Velocity meters, the vane wheel and the Woltmann turbine, count spins. For factory pipes there are the orifice plate, the venturi and the rotameter. Also how to read meters, find leaks and test meters against a measured tank or a gas bell.
- Difficulty
- ●●●●●
- Time
- A week to build a wet gas meter or an orifice meter; a month to make and test a first batch of piston water meters; minutes to read or check one
- Steps from zero
- 49 prerequisites →
This unlocks
Instruments, Chart Recorders and Control RoomsObjects made here
water meterturbine metergas meterwet gas meterorifice plateventuri meterrotametermeter proverRaw materials
hideThe full path from nothing — 49 steps before this one
- Fire
- Cordage and Rope
- Stone Tools
- Finding and Preparing Clay
- Finding and Identifying Ores
- Measurement from Scratch
- Writing and Numbers
- Hunting and Trapping
- Basic Woodworking
- Pottery
- The Kiln
- Charcoal
- Arithmetic and Fractions
- Hides and Leather
- Tiles and Clay Pipes
- Salt
- Lime
- Bricks
- Surveying and Levelling
- Fermentation
- Lye and Potash
- The Wheel and Axle
- Glass
- Firebrick and Refractories
- Bellows
- Distillation
- The Lathe
- Gears
- Lead
- Iron (the Bloomery)
- Copper Smelting
- Laboratory Glassware
- Pumps
- The Waterwheel
- Blacksmithing
- The Blast Furnace and Cast Iron
- Pipes, Plumbing and Aqueducts
- The Battery
- Steel
- The Steam Engine
- Bellows to Air Compressors
- Electrolysis
- Hydrogen, Oxygen and Gases
- Machine Tools
- Petroleum and Refining
- Ammonia
- Ice and Refrigeration
- Liquid Air, Nitrogen and the Noble Gases
- Natural Gas and Helium
- Water and Gas Meters
Do them roughly in this order. See it on the tech tree →
Why it matters
Once water and gas come by pipe to every house (Pipes, Plumbing and Aqueducts, Natural Gas and Helium), someone must pay for the reservoirs, mains and gas works. A flat charge is easy, but people waste what costs them nothing, and a town whose mains run dry every summer may be losing a third of its water to leaks and waste. A meter makes each user pay for what they take, and shows leaks: a meter that turns while every tap is shut.
Factories need flow meters to control their processes: how much feed water enters a boiler (Boilers and Pressure Vessels), how fast each stream runs into a reactor. Electricity meters are in Electricity Meters and Billing; registers, seals and testing work much the same way.
How it works
There are three ways to measure a flow.
- Positive displacement: the fluid fills a chamber of known size and is let out; a counter adds up the fillings, like counting buckets. Accurate at low flows. Household water and gas meters work this way.
- Velocity: the fluid spins a vane wheel or turbine at a speed in proportion to the flow. Passes large flows, but blind to trickles.
- Differential pressure: squeeze the flow through a narrower passage; it speeds up and its pressure drops (Bernoulli's principle, Hydraulic Presses and Rams). The drop tells the flow. No moving parts at all.
Units. Water is billed in cubic metres (1 m³ = 1,000 litres). Gas is metered in cubic metres too, but billed by the heat it gives: natural gas gives about 10–11 kWh per cubic metre (38–40 MJ), coal gas about half that (Coal and Coke).
Accuracy. A good meter reads within ±2% over its normal range, and within ±5% at its lowest rated flows. Below its starting flow, a few litres an hour for a house water meter, it does not move at all.
What you need
| Item | Use | See |
|---|---|---|
| Bronze or brass castings | Meter bodies, chambers | Metal Casting, Zinc and Brass |
| Lathe, fine boring and lapping | Pistons and chambers to a few hundredths of a millimetre | The Lathe, Precision Grinding |
| Hard rubber, horn or ebonite | Pistons, vane wheels: light and do not rust | Rubber, Horn and Bone Working |
| Tinned sheet iron, solder | Gas meter cases and drums | Sheet Metal and Rolling, Soldering and Brazing |
| Supple leather or rubberised cloth | Gas meter diaphragms | Hides and Leather, Rubber |
| Small gears, digit wheels | Registers | Clockwork, Music Boxes and Counting Machines, Gears |
| Small permanent magnets | Coupling the register through a wall | Permanent Magnets |
| Glass tube, U-tube manometers | Rotameters, differential pressure | Scientific Glassblowing and Glass-to-Metal Seals, Pressure and Vacuum Gauges |
| Calibrated tank, scale, clock | Testing | Balances, Steelyards and Weighing Machines |
The water meter
The rotary piston meter
This is the classic household meter: a cast brass body about 16 cm long between its two 15–20 mm pipe unions, with a dial on top. Inside, a hollow ring-shaped piston rolls round a cylindrical chamber.
How it works. The chamber is a short cylinder with a fixed hub in its middle and a fixed radial partition running from hub to wall. The ring piston, a thin cylinder a little smaller than the chamber, carries a slot that rides on the partition, and a pin at its centre that runs round a circular track. Water enters through a port on one side of the partition and leaves through a port on the other. The water pushes the piston round with a rolling, wobbling motion; each orbit of its centre passes one fixed volume of water, a few tens of millilitres in a house meter, whatever the pressure or speed.
Making it.
- Chamber: cast in bronze, bored and faced on the lathe. The bore and the faces must be true to about 0.02 mm; check with a plug gauge and a straight-edge (Rules, Squares, Callipers and Gauges).
- Piston: turned from hard rubber or ebonite (Rubber), which is light, does not corrode and swells hardly at all in water. Make it 0.03–0.05 mm smaller than the space it runs in. Too tight and it sticks when grit arrives; too loose and water slips past uncounted at low flow.
- Ports: in the bottom plate, one each side of the partition, shaped by trial so the piston uncovers them smoothly.
- Strainer: a fine brass gauze in the inlet stops sand and pipe scale.
- Register: the piston pin turns a gear train reducing about 1,000 to 1 or more to a row of digit wheels (Clockwork, Music Boxes and Counting Machines). In a wet dial meter the gears run in the water under a thick glass. In a dry dial meter the register is sealed in its own dry box and driven through the brass lid by a pair of small magnets, one inside, one outside; the register stays readable for decades.
Good or bad? A good meter starts turning at a trickle of 5–10 litres an hour, reads within 2% at all ordinary flows, and makes no noise. A worn one under-reads at low flows, the leakage past the piston going uncounted.
The nutating disc meter, common in America, uses a disc that wobbles like a spun coin in a spherical chamber, with a fixed partition. It works the same way and is made the same way.
Velocity meters: the vane wheel and the Woltmann turbine
For big flows a piston meter would be huge, so a velocity meter counts spins instead.
- Vane wheel (single-jet or multi-jet) meter: a light paddle wheel of hard rubber or plastic, like a small The Waterwheel, in a round chamber. Water enters through one or several slanting jets around the side and drives it round. Cheap and tolerant of dirty water, but it reads poorly below about a tenth of its rated flow.
- Woltmann turbine meter: for mains of 50–500 mm. A rotor with helical blades like a ship's propeller sits along the pipe axis, on jewel or hard-steel pivots. Its speed is in proportion to the flow over a range of about 20 to 1. A straight length of pipe at least 10 diameters upstream gives it smooth flow; a bend just before it makes the flow swirl and spoils the reading.
Set a velocity meter on the test bench (below), by an adjustable vane or a screw that lets some water bypass the jets. A combination meter joins a big turbine and a small piston meter with a spring valve, so trickles take the small one and rushes open the big one.
The gas meter
The wet gas meter
The first practical gas meter, and the easiest to build. It is still used in laboratories as an accurate standard.
- Case: a horizontal cylinder of tinned sheet iron (Sheet Metal and Rolling), for a house about 40 cm across and 30 cm deep, filled with water to a little above its axle. A sight glass or an overflow plug marks the exact level.
- Drum: inside, a drum on a horizontal axle, divided into four chambers by curved partitions like the blades of a turbine, each chamber with a slot near the axle (the inlet) and a slot at the rim (the outlet).
- Gas enters through a pipe rising inside the case to just above the water at the drum's centre, and fills whichever chamber has its inlet slot above water. The filling chamber floats up, turning the drum, until its outer slot clears the water and the gas escapes to the outlet; meanwhile the next chamber fills.
- Register: the axle turns a gear train and dials through a gland in the case end (Packing, Gaskets and Seals). Each turn of the drum passes the volume of the four chambers above the water line, which you measure by test.
Good or bad? It is accurate to about half a percent if the water level is exact: a lower water level leaves the chambers bigger and the meter reads low. It needs topping up, and it freezes in winter unless a little glycerine is added.
The bellows (diaphragm) gas meter
The dry meter that replaced the wet meter in houses, and is still made by the million. A tin or pressed-steel box about 25 cm wide, 30 cm high and 16 cm deep.
How it works. Each of two chambers is split by a diaphragm of supple leather (now synthetic rubber), stiffened in the middle by a metal plate. On top, two slide valves like those of a The Steam Engine move over grids of three ports, letting gas into one side of each diaphragm while the other side empties to the outlet. The moving diaphragm swings a flag rod that turns a little crank, and the crank moves the valves. The two chambers are a quarter-cycle apart, like the two cylinders of a locomotive, so the meter always starts. Every turn of the crank passes a fixed volume, about 1.2 litres in a common house meter, and the crank also drives the register.
Making it.
- Diaphragms: choose thin, even sheepskin leather (Hides and Leather), soak it in a mixture of neat's-foot oil and a little tallow so it stays supple and gas-tight for years, and clamp it between the rim of the chamber and a ring with 20–30 small screws. Leave slack so it can move 2–3 cm each way without stretching.
- Valves and grids: cast brass or moulded hard rubber, lapped flat on a glass plate with fine abrasive (Abrasives and Grinding Stones) until no light shows between them.
- Crank and flag rods: brass, with the crank's throw adjustable by a screw. Lengthening the throw lengthens the stroke of the diaphragms and increases the volume per turn; this is how the meter is calibrated.
- Case: tinned sheet iron, soldered, tested under water with air at three times working pressure for leaks. Paint it.
Good or bad? A good bellows meter uses only a few millimetres of water of pressure to drive itself, so the gas flame does not flicker, starts at a few litres an hour, and reads within 2%. A meter with dry, cracked diaphragms leaks gas through the diaphragm without counting it, and reads low; one with sticky valves makes the cooking flames pulse.
Flow meters for factories
The orifice plate
The simplest flow meter: a thin plate with a sharp-edged round hole, clamped between pipe flanges, with a U-tube manometer (Pressure and Vacuum Gauges) joined to small holes in the pipe just before and after it.
Making it.
- Cut the plate from stainless steel or bronze, 2–3 mm thick for a pipe up to 150 mm. Bore the hole on the lathe to a diameter d between 0.3 and 0.7 times the pipe bore D. The ratio d/D is called beta.
- Keep the upstream edge perfectly square and sharp: no burr, no rounding. On the downstream side, bevel the hole at 45° so the sharp part is less than 1/50 of D thick.
- Leave a tab sticking out between the flanges, stamped with the hole size and a flow arrow.
- Drill pressure tappings, holes of 6–10 mm, one pipe diameter upstream and half a diameter downstream of the plate, free of burrs inside the pipe.
- Give it at least 10–20 diameters of straight pipe upstream and 5 downstream. More after valves and pairs of bends.
Working out the flow.
Flow (m³/s) = 0.61 × area of hole (m²) × √(2 × pressure drop (Pa) ÷ density (kg/m³)) ÷ √(1 − β⁴)
The figure 0.61 is the discharge coefficient, found by experiment: the jet keeps narrowing for a short way after the hole, so it is smaller than the hole.
Example. Water in a 100 mm pipe, a 50 mm hole (β = 0.5, hole area 0.00196 m²), manometer showing 2 m of water (about 20,000 Pa). √(2 × 20,000 ÷ 1,000) = 6.3. √(1 − 0.0625) = 0.97. Flow = 0.61 × 0.00196 × 6.3 ÷ 0.97 = 0.0078 m³/s, about 7.8 litres a second, or 28 m³ an hour.
The square-root problem. The pressure drop grows with the square of the flow. Half the flow gives a quarter of the drop; a tenth of the flow gives a hundredth, too small to read. So one orifice reads well over only about a 3 or 4 to 1 range. For wide ranges, fit two plates or a more sensitive manometer (inclined manometer).
Price: an orifice wastes pressure. About half to three quarters of the drop it shows is lost for good, which costs pumping power.
The venturi meter
The venturi meter does the same with smooth cones instead of a sharp plate, and gives most of the pressure back.
- Inlet cone: narrowing at a total angle of about 21° to the throat.
- Throat: a short straight section, as long as it is wide, with diameter one third to three quarters of the pipe.
- Outlet cone: widening slowly, at 5–15° total angle, back to the pipe size. Too steep and the flow breaks away from the wall, swirls and wastes the pressure.
- Tappings: in the pipe just before the inlet cone, and in the middle of the throat. Large venturis use a ring chamber round each, joined to the pipe by four or more small holes, to average out the pressure.
Cast it in iron or bronze in flanged pieces, bore the throat smooth and file the joins flush. Use the orifice formula with a coefficient of 0.98 instead of 0.61. Only 10–15% of the drop is lost, so venturis suit town mains and power-station cooling water (Cooling Towers and Spray Ponds). A pitot tube, a small bent tube facing upstream, measures speed at one point in a pipe, duct or river by the same principle (Ventilation and Air Conditioning, Gliders and Aeroplanes).
The rotameter
The rotameter (or variable-area meter) is a vertical glass tube, wider at the top than the bottom, with a float inside. Fluid flows upward. The float rises until the ring-shaped gap between it and the wall is just big enough to pass the flow; its weight then balances the push of the flow. A scale on the glass reads the flow directly, and it reads well over a 10 to 1 range.
- The tube: a glass tube whose bore widens evenly, for example from 10 mm at the bottom to 14 mm at the top over 25 cm. The accurate way is to heat a thick glass tube under vacuum over a polished, tapered steel mandrel; the glass shrinks onto it, and when cool the steel shrinks more and slides out (Scientific Glassblowing and Glass-to-Metal Seals). A simpler route: a straight glass tube with a tapered metal rod standing up its centre and a ring-shaped float riding on the rod. The gap widens as the float rises just the same.
- The float: a small bobbin of stainless steel, glass, hard rubber or aluminium, with a sharp top edge, which is where you read. Cut a few slanting notches in its rim: the flow then spins it, which centres it and stops it sticking. That spin gave the rotameter its name.
- End fittings: brass, packed with rubber rings, with stops to keep the float from leaving the tube.
- Calibrate with a bucket and a clock (water) or a soap-bubble tube or wet meter (gas): mark the float's position at five or six flows and draw the scale.
Mount it truly vertical. A scale is good for one fluid only: one for air is wrong for oxygen. Rotameters set the gas flows of anaesthetic machines (Anaesthesia), hospital oxygen, laboratory burners and chemical dosing (Water Treatment for a Town).
Reading a meter
- Digit wheels: read straight off, whole cubic metres in black, litres or tenths in red. Write down the black figures.
- Dials: read as for electricity dials (Electricity Meters and Billing). Neighbouring dials turn opposite ways. Take the number each pointer has just passed; if a pointer seems to sit exactly on a number, look at the dial of the next lower value: if it has not yet passed zero, take one less.
- Consumption = this reading − last reading. A family of four uses roughly 0.4–0.6 m³ of water a day with taps, a flushing toilet and a washing machine (Toilets, Sinks, Baths and Showers), and 1–3 m³ of gas a day for cooking and heating, much more in a cold winter.
Finding leaks. Shut every tap and appliance. Watch the tell-tale, the small star or triangle that turns with the slightest flow, or the litre dial, for 15 minutes. Any movement means a leak: a dripping tap, a running toilet cistern, a broken pipe underground. For gas, any movement with every burner and pilot light off means gas is escaping: shut the main valve and find the leak with soapy water (Natural Gas and Helium).
Testing meters
Test meters when new, after repair, every 5–15 years, and when a customer disputes a bill.
Water meters: the test bench. Fit the meter in a straight pipe fed from a header tank at steady pressure (Pipes, Plumbing and Aqueducts), with a valve after it to set the flow and a measuring tank after that. Make it tall and narrow, with a glass gauge tube, and calibrate its scale with weighed water (1 kg = 1 litre, Balances, Steelyards and Weighing Machines).
- Read the meter's litre dial. Open the valve to the chosen flow.
- Pass at least 100 litres, or 10 turns of the finest dial, whichever is more.
- Shut the valve. Read the meter and the tank.
- Error = (meter reading − tank reading) ÷ tank reading × 100%.
- Repeat at three flows: low (about 1/50 of rated flow), middle, and full. Allow ±5% at the low flow and ±2% above.
Gas meters: the bell prover. A meter prover is a small, very accurate gasholder: a bell of sheet metal, for example 50 litres, floating in a tank of water or light oil, with a scale on the side read against a pointer. Weights on a cord over a pulley set the pressure under the bell at that of a house supply.
- Fill the bell with air. Connect it to the meter.
- Open the cock and let the bell sink through a measured volume, 10 to 50 litres, while you watch the meter's test dial.
- Compare. Correct for temperature if bell and meter differ: gas swells about 0.37% per °C.
- Calibrate the prover itself once, from its carefully measured dimensions or by filling the bell with measured water.
Adjust a meter that reads wrong, by its regulating screw, vane or crank throw, then seal it with a lead seal on a wire through the cover screws (Electricity Meters and Billing), so the setting cannot be changed without the seal being broken.
How to tell it worked
- The meter agrees with the test tank or prover within 2% at normal flows.
- With every tap shut, the tell-tale is still. With one tap barely dripping, it creeps.
- An orifice or venturi meter checked by timing the filling of a tank of known size agrees within 2–3%.
- A rotameter float sits steady, not bouncing, and returns to the same mark for the same valve setting.
Note Troubleshooting. Water meter stopped → grit jammed in the piston or wheel; clean the strainer; flush the service pipe before fitting a meter to a new supply. Water meter reads high → air in the pipe spins velocity meters; vent the pipe. Gas flames pulse or flicker → bellows meter valves sticking or diaphragms stiff; clean and re-oil, or replace diaphragms. Orifice meter reads wrong → plate in backwards (bevel must face downstream), edge rounded by wear or dented, too little straight pipe upstream, air bubbles in the manometer lines. Rotameter float sticks → dirt on the glass, tube not vertical, or float notches worn; clean with weak acid (Hydrochloric Acid) and rinse.
Dangers
Danger Gas. Before taking out or fitting a gas meter, shut the main valve, open no flame near, and keep a window open. After fitting, test every joint with soap solution and purge the air out before lighting (see Natural Gas and Helium). A leaking meter or union in a closed cupboard can fill a house with gas: a spark from a switch then blows it apart. Gas also carries carbon monoxide if it is coal or water gas: escaping gas can poison sleeping people (Coal and Coke).
- Mercury in old manometers gives off poisonous vapour when spilled (Mercury).
- Pressure. Do not open a meter, orifice flange or rotameter on a live line. Glass rotameter tubes can burst: fit a guard and keep their pressure low, and use metal-tube meters with magnetic followers for steam and high pressure.
- Contamination. A meter fitted to a drinking supply must be disinfected (rinsed with chlorine solution, Chlorine and Bleach) and never be connected to a line that can siphon dirty water back.
What this unlocks
Metering lets a water company or gas works charge fairly, find leaks and plan new reservoirs (Dams and Reservoirs). Flow meters give the measurements that let factories run steadily: boiler feed, cooling water (Cooling Towers and Spray Ponds), chemical dosing (Water Treatment for a Town), and, with a pen on a paper chart (Instruments, Chart Recorders and Control Rooms) and later an electrical signal, the automatic control of whole plants (Process Controllers and Control Valves, Robots and Automation).
How it was first done
The Romans charged for water by the size of the bronze nozzle (calix) that let it into a house, and Frontinus, their water commissioner, wrote about fraud with oversize nozzles in about AD 97. Reinhard Woltmann of Hamburg made a vane meter for measuring river flow in 1790. Samuel Clegg built the wet gas meter in London in 1815, and Samuel Crosley improved it into a commercial success; Thomas Glover patented the dry bellows meter in 1843–44, and it slowly displaced the wet meter. The American engineer Clemens Herschel built the venturi meter in 1887, naming it after the Italian Giovanni Battista Venturi, who had studied flow through cones a century before. The rotameter was patented by Karl Kueppers in Aachen, Germany, in 1908.