◆ Rebuild

Part 11 · Power and Energy

Geothermal, Tidal and Wave Power

Three kinds of power that do not depend on the weather — the Earth's own heat, the pull of the moon and the swell of the sea. Bathing pools, heated houses and greenhouses, geothermal steam and binary plants, tide mills with a pond and a flap gate, tidal barrages and underwater turbines, and an honest look at wave machines.

Difficulty
●●●●●
Time
A bathing pool in a day; a tide mill in a season; a geothermal power plant needs deep drilling and an industry
Steps from zero
45 prerequisites →

You need first

Water Turbines and Hydroelectric PowerHeat ExchangersThe Steam Turbine

This unlocks

—
The full path from nothing — 45 steps before this one
  1. Stone Tools
  2. Fire
  3. Cordage and Rope
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Basic Woodworking
  7. Hunting and Trapping
  8. Charcoal
  9. Pottery
  10. The Kiln
  11. Hides and Leather
  12. Bricks
  13. Lime
  14. Mercury
  15. Lye and Potash
  16. The Wheel and Axle
  17. Firebrick and Refractories
  18. Glass
  19. Bellows
  20. Gears
  21. The Lathe
  22. Iron (the Bloomery)
  23. Copper Smelting
  24. Laboratory Glassware
  25. The Waterwheel
  26. Blacksmithing
  27. The Blast Furnace and Cast Iron
  28. Magnets
  29. The Barometer
  30. Sheet Metal and Rolling
  31. Steel
  32. The Steam Engine
  33. Copper Wire
  34. Machine Tools
  35. Boilers and Pressure Vessels
  36. The Generator
  37. The Electric Arc Furnace
  38. Water Turbines and Hydroelectric Power
  39. The Steam Turbine
  40. Calcium Carbide and Acetylene
  41. Welding
  42. Metal Pipes and Tubes
  43. Pressure and Vacuum Gauges
  44. Pressure Vessels and Valves
  45. Heat Exchangers
  46. Geothermal, Tidal and Wave Power

Do them roughly in this order. See it on the tech tree →

Why it matters

Sun and wind stop. The Earth's heat and the moon's pull do not. A hot spring gives the same warm water at night in February as at noon in July, and the tide comes in twice a day on a timetable you can print years ahead (Tides, Tide Gauges and Tide Tables). Where these sources exist they are the steadiest power a rebuilding people can have, and the first use — warm water — needs no machinery.

They are also strictly local: geothermal heat lies in a few volcanic regions and a scatter of warm springs, useful tides in certain funnel-shaped estuaries, strong waves on exposed ocean coasts. Most places have none of them and should read Water Turbines and Hydroelectric Power, The Windmill and Firewood and Coppicing instead.

How it works

Geothermal. The Earth is hot inside and the heat leaks outward through the rock. On ordinary ground the temperature rises only about 25–30 °C for every kilometre of depth: at 100 m the rock is barely 3 °C warmer than the surface, which is useless to a digger. What makes geothermal power possible is water circulating in cracked rock over a body of magma, carrying heat up to where you can reach it. Then 200 °C may lie 500 m down instead of 7 km down, and a spring may deliver boiling water at the surface for nothing.

The uses need very different temperatures:

Temperature of the water What it will do
10–30 °C A heat source for a heat pump; warming fish ponds (Fish Ponds) and soil
30–60 °C Bathing, washing, laundry, house and greenhouse heating, drying grain, fruit and timber
60–100 °C District heating a whole town; cooking; boiling down brine for Salt; low-grade industry
100–180 °C Electricity through a binary plant, at 5–12% efficiency
above 180 °C Electricity through flash or dry steam turbines, at 10–20%

Why so inefficient? A heat engine's best possible efficiency is set by its two temperatures (The Steam Turbine): between 150 °C and 30 °C the ideal limit is about 28%, and real machines reach a third of that. So use the heat directly wherever you can.

Tidal. Trap high water behind a wall and let it out through a wheel as the sea drops, and you have a water mill whose river is the moon. The energy in one filling of a pond is

E ≈ ½ × ρ × g × A × R²

where ρ is 1,000 kg per m³ for water, g is 9.8, A is the pond's area in square metres and R the tidal range in metres. The water's average fall is only half the range, which is where the ½ comes from, and because the range is squared a coast with a 6 m range is worth four times one with 3 m. Spring tides give several times the energy of neaps (Tides, Tide Gauges and Tide Tables).

The other way is to put a turbine straight into a tidal race — the fast current between islands or through a sound — and take energy from moving water as a Wind Turbines takes it from moving air:

P ≈ ½ × ρ × A × v³ × C

with ρ 1,025 for seawater, A the area the rotor sweeps, v the current in metres a second and C the fraction you can capture, about 0.35–0.45. Seawater is some 800 times denser than air, so a rotor 10 m across in a 2.5 m/s current gives about 250 kW — what a wind turbine needs a 40 m rotor to match.

Wave. Waves are wind energy gathered over hundreds of kilometres of ocean and concentrated into a line. The power arriving per metre of crest is roughly

P ≈ 0.5 × H² × T kilowatts per metre

with H the height from trough to crest of the larger waves, in metres, and T the time between crests, in seconds. Waves 2 m high every 8 seconds bring about 16 kW for every metre of shore they strike. Capturing it is another matter.

Where to find it

Signs of usable geothermal heat, in rough order of promise (Rocks and Minerals):

  • Steam vents and geysers — the hottest ground of all, and the most dangerous.
  • Hot springs: pools that steam on a cold morning, streams that never freeze, bright green algae and moss growing in winter.
  • Mineral crusts around springs: white or grey sinter (silica, like hard frozen foam) at the hottest ones, cream travertine terraces (lime) at cooler ones, yellow Sulfur and white borate crusts (Borax and Boric Acid) around volcanic steam.
  • Warm ground: snow melting in patches, soil warm to the hand 30 cm down, frost-free ground in a hard winter.
  • Cone-shaped hills, lava flows, young volcanic rock (dark, glassy, full of bubbles), earthquakes, a smell of rotten eggs.

Measure before you build: put a The Thermometer in the spring source itself, not the pool, and time the filling of a bucket to get the flow. A spring giving 1 litre a second at 60 °C, cooled to 20 °C, carries about 170 kW of heat — enough for twenty well-insulated houses. Record both monthly for a year, because springs change with rain and with earthquakes.

Signs of usable tides (Tides, Tide Gauges and Tide Tables, Harbours and Lighthouses):

  • A range of 3 m or more at springs. Below about 2 m, a tide mill is rarely worth the wall.
  • A creek, inlet or salt marsh with a narrow mouth, so a short dam encloses a wide pond. The ideal is a bottle-shaped bay.
  • Firm ground for the dam — rock or stiff clay, not deep soft mud.
  • For a stream turbine: a race where the current runs faster than about 2 m/s (fast walking pace; it pulls hard on an oar), between headlands, through a sound, or at the mouth of a large bay.

Signs of usable waves: a coast facing thousands of kilometres of open ocean, with deep water close in — the western coasts of Europe, the Americas, southern Africa and Australia. Sheltered seas and lee shores have little.

Direct use of geothermal heat

This is where nearly all the value is, and it needs only pipes.

hot spring, tappedwhere it leaves the rocksettling tankheatexchangerbathing pool, mixed to 37–40 °Cgreenhouse, 30–40 °Chouse, 30–45 °Cto the stream,below any well Hot spring water (red) never enters the house pipes; a clean loop (blue to orange) heats house and greenhouse
Fig. 1 Using a hot spring. The water is tapped and settled, then passed through a heat exchanger that keeps the corrosive spring water out of the house pipes: a clean loop carries the heat to the house and the greenhouse beds, while the cooled spring water fills a bathing pool and then returns to the stream.
  1. Tap the source, not the pool. Dig back to where the water leaves the rock, line the chamber with stone and clay, cover it, and lead the water away in a pipe or stone channel rather than an open ditch (Insulation and Keeping Buildings Warm or Cool, Tiles and Clay Pipes).
  2. Settle it. Spring water carries sand, silica and lime that block pipes. Give it a settling tank and clean that out on a fixed day each month.
  3. Keep it out of your plumbing. Geothermal water is usually salty, acidic or full of sulfide and eats iron and copper (Corrosion and Its Prevention). Run it through a heat exchanger and circulate clean water round the house instead.
  4. The uses, in order of worth: bathing and washing (Personal Hygiene); house heating with floor pipes or large radiators at 30–45 °C (Hot Water and Central Heating) from a buried main lagged with 10 cm of insulation; greenhouses with pipes under the beds at 30–40 °C, which add months to the growing season (Cold Frames, Cloches and Greenhouses); drying grain, fruit, fish and timber in a warm air current, a huge saving of firewood; and warm ponds for fish.
  5. Return the water to the ground, or to the stream below any drinking supply. Hot, salty water kills a river.

Where there is no spring, the ground below about 2 m still sits at the yearly average air temperature. A buried geothermal heating loop — a few hundred metres of pipe in a trench 1–2 m deep, or a vertical loop down a borehole — feeds a heat pump that delivers three to five units of heat for one of power; the sizes, fluids and pitfalls are all in Heat Pumps and District Heating.

Geothermal electricity

1. Dry steam2. Flash steam3. Binary steam from the well, above 180 °Chot water, 180–250 °Cwater from 100 °C up steamcondenserGseparatorhot waterback downheatexchangersecond fluidcondensedGGvapour of butaneor pentane wellwellwell10–20% efficient10–20% efficient5–12% efficient
Fig. 2 Three kinds of geothermal power plant. In a dry steam plant the well delivers steam straight to the turbine. In a flash plant hot water under pressure is let into a separator, where part of it flashes into steam. In a binary plant the water never leaves its own circuit: it boils a second liquid with a low boiling point, which drives the turbine.
  • Dry steam — the simplest and the rarest. The well gives steam, not water. Clean it of grit in a cyclone, dry it, and send it to a The Steam Turbine. Larderello in Italy has run this way since 1913.
  • Flash steam — the common kind. Water at 180–250 °C comes up under pressure; let into a vessel at lower pressure, perhaps 10–20% of it flashes into steam, which runs the turbine. The hot water left behind can be flashed again or used for heating.
  • Binary (organic Rankine) — the one that works at low temperature, from about 100 °C up, and the only sort a small group should consider. The geothermal water stays in its own loop and never touches the machine. It passes through a heat exchanger and boils a second fluid whose boiling point is low — butane, pentane or ammonia — and the vapour of that drives the turbine and is condensed by river water or a cooling tower and pumped round again. It is a refrigerator run backwards, built of the same parts.

Warning A binary plant's working fluid is flammable under pressure: leaking butane or pentane finds any flame and burns back to the plant, and ammonia is poisonous and blinds. Put the machine outdoors or in a well-vented shed, keep flame away, and fit relief valves venting upward and outdoors (Pressure Vessels and Valves).

Be honest about the drilling. Every geothermal power plant stands on cased wells 500–3,000 m deep, drilled by a rig with a derrick, mud pumps and steel pipe (Drills and Boring, Petroleum and Refining). That is an industry, not a project. Until you have it, geothermal electricity must come from a spring already hot at the surface: at most a binary plant of a few tens of kilowatts, worth less than using the heat directly.

Scaling and reinjection. Geothermal water is saturated with silica and lime, and as it cools it lays them down as hard white scale that closes a pipe in months. Keep it above about 70 °C wherever it flows fast, make pipes straight with screwed plugs at the bends, and rod them out on a schedule. Put the spent water back down a second well: fields that were simply drained have lost much of their pressure within decades.

Tide mills

A tide mill is the achievable tidal machine: a pond, a wall, a gate and a waterwheel. Hundreds worked in Europe for a thousand years.

Millpond, filled by the floodThe sea, fallingabout five hours of workFlap gate, hinged at the topopens to the flood, shuts on the ebbHand gate in the sluicestarts and stops the millUndershot wheel, 3–5 m across6–10 turns a minute into the mill gearingMill house, above spring high waterworking head Dam of earth with a clay core,faced seaward with heavy stone
Fig. 3 A tide mill. A one-way flap gate in the dam lets the flood tide fill the pond and slams shut as the sea drops; the mill then runs for about five hours on the falling tide, discharging through an undershot wheel into the sea.

Size it first

Work out the energy before you move a stone. For a pond of area A and range R:

  • Usable water = A × R cubic metres. Average fall = R ÷ 2.
  • A pond of 1 hectare (100 m × 100 m) with a 3 m range holds 30,000 m³ falling an average of 1.5 m: about 120 kWh of raw energy per tide.
  • An undershot wheel and wooden gearing take perhaps 30% of that: 35 kWh per tide, or about 7 kW for five hours, twice a day. That is a good grain mill, grinding some 200–400 kg of flour a tide (The Watermill, Ball Mills, Crushers and Grinders).
  • With a 6 m range the same pond gives four times as much.

Build it

  1. Survey the site at spring low and high water and mark both lines (Surveying and Levelling). A wide, shallow flat is worth more than a deep hole.
  2. Build the dam across the narrowest point, as an earth bank with a clay core and a stone face or as a masonry wall; the cutoff trench and the failure modes are in Dams and Reservoirs. Sea, waves and ship-worm are harder on it than a stream, so face the seaward side with heavy stone (Harbours and Lighthouses) and use oak below water.
  3. Fit the flap gate, the heart of the thing: a heavy wooden flap hinged at the top of an opening in the dam, swinging landward only. The rising sea pushes it open and fills the pond; as the sea falls, the pond's own water swings it shut. Make it of 5 cm oak planks on a frame with a leather or rope seal and a stop to limit its swing. Several small gates fill the pond faster than one big one and fail more gracefully.
  4. Put the wheel in a sluice through the dam, with a hand-worked gate above it so you can start and stop (sluices). An undershot wheel suits this low head: 3–5 m across, paddles 30–45 cm deep, 6–10 turns a minute. On 2–3 m of head a crossflow turbine takes far more of the energy, if you can cast and machine one.
  5. Build the millhouse above spring high water, with the machinery dry and the wheel pit free to flood.
  6. Work to the clock the sea gives you. Milling starts when the sea has fallen about half a metre below the pond and stops when the levels meet, and each day it starts about 50 minutes later (Tides, Tide Gauges and Tide Tables), so a tide miller works nights for half of every fortnight. That is the real cost of tidal power.

Tip A tide mill and a stream mill on the same site cover each other: the stream runs the quiet months, the tide runs the dry ones. Where a stream enters the pond, you get both.

Tidal barrages and stream turbines

A tidal barrage is a tide mill grown to the size of an estuary, with turbines in the wall: a hydro dam and a sea wall together, with deep foundations in salt water and gates of many tonnes. La Rance in Brittany (1966) has 24 turbine-generators of 10 MW in a dam 750 m long across an estuary whose spring range reaches about 13 m. These are works for a restored industrial society, and they silt the estuary, block fish and boats and drown the mud flats that feed birds.

A tidal-stream turbine needs no dam. It is an underwater Wind Turbines: a rotor on a pile in the sea bed or slung under a moored raft. Because the current reverses, either the blades pitch round or the whole machine swings. Keep the rotor at least 5 m below the surface so boats and storm waves miss it, and make every bearing and seal survive salt, weed, barnacles and sand — and be reachable at slack water. The first commercial machine, SeaGen, ran in Strangford Lough in Northern Ireland from 2008 at 1.2 MW.

Start instead with a floating undershot wheel moored in a tidal race, like a river boat mill: two hulls, a paddle wheel between them, and a mooring that lets it swing with the current. The power is modest, but it needs no concrete and no divers.

Wave power, in outline

Waves are the hardest of the three to harvest, for one reason: the sea destroys machines. A device must take a 2 m swell every eight seconds for twenty years and also survive the 15 m waves of a once-in-fifty-years storm. Almost every full-size wave machine ever built has been sunk, torn from its moorings or wrecked. Treat wave power as a late project, after Boats and Sails, Harbours and Lighthouses and Corrosion and Its Prevention.

Oscillating water columnPoint absorber swellpushes inwall open below the waterlineair turbineair outair in float ridesthe wavespump: lifts water to asalt pan or a fish pondanchor or heavy plate on the sea bed
Fig. 4 Two wave machines. In an oscillating water column the swell drives air in and out of a chamber through a turbine at the top. In a point absorber a float rides the waves and works a pump or a rack against a weighted or anchored base.
  • Oscillating water column — the most robust, because the only moving part is in the air. Build a concrete or masonry chamber on a rocky shore, open to the sea below the waterline and closed above, with a hole at the top. Each wave pushes the water up inside like a piston and blows air out of the hole; each trough sucks it back. Put a turbine in the hole, ideally one that spins the same way whichever way the air blows. A small column with a whistle in place of a turbine has marked shipping channels for over a century, and that wave-powered whistle buoy is the one wave device a small group can certainly build (Harbours and Lighthouses).
  • Point absorber — a float that rides up and down and works a pump against an anchored base or a heavy submerged plate. The useful form is a wave-driven pump that lifts seawater into a salt pan (Salt) or a raised pond; turning the motion into smooth electricity is much harder.

Whatever the machine, the moorings are the hard part: let it ride over the worst seas rather than stand against them.

How to tell it worked

  • A geothermal supply is right when the delivered water is within a few degrees of the spring, month after month; the heat exchanger's output falls by no more than 10% over a season (more means scale — open and rod it); and no pipe is warm on the outside where it should be lagged.
  • A tide mill is right when the pond fills to within 10 cm of high water each tide (if not, the gates are too small or leaking), when the mill runs for 4–6 hours each tide, and when the dam shows no new wet patch or sinkhole on its landward face after springs.
  • Any sea machine is right when you can still turn every moving part by hand after a winter.

Note Troubleshooting. Hot spring runs cooler or weaker → rain diluting it, or your own pumping drawing in cold ground water. Measure for a year before sizing anything on it. Pipes block within months → silica or lime scale: keep the water hotter and fit rodding plugs at every bend. Pond does not fill → the flap gate is jammed with weed or silt, or the dam leaks faster than the tide fills it. Clear the gate at every low water. Wheel runs fast then stops early → the sluice is too wide: narrow it so the pond empties over the whole working tide. Everything below water is furred with weed and barnacles → normal; plan a way to lift it and clean monthly.

Dangers

Danger Hot springs scald and kill. Water at 60 °C burns adult skin in about five seconds, and at 70 °C almost instantly. The ground around geysers and steam vents is often a thin crust over boiling mud that gives way under a foot: people die this way every few years in every geothermal area on Earth. Stay on rock you have tested, never walk on pale crusty ground, never let children run, and never bathe in a pool whose source you have not measured — many springs surge without warning. For bathing, mix the spring with cold water to 37–40 °C, limit a hot soak to 10–15 minutes, never bathe alone, and never after drinking alcohol.

Danger Bad air collects around volcanic ground. Carbon dioxide and hydrogen sulfide pour out of the same cracks as the heat, are heavier than air, and gather in hollows, cellars, pits and closed bath houses — where they have killed whole families. Hydrogen sulfide smells of rotten eggs at first and then paralyses the sense of smell just as it becomes deadly (Natural Gas and Helium). A burning candle does not prove the air is safe: carbon dioxide can knock you out at levels a flame survives, and hydrogen sulfide kills at levels far too small to dim one. Ventilate every bath house high and low, never sleep in a hollow near a vent, never enter a pit or tank near a spring, and never go down after someone who has collapsed — send for rope, air and help (Emergencies).

Danger The sea takes people. A tidal pond, a sluice and a barrage are drowning traps: the current through a gate will pull a strong swimmer under, and the flood tide crosses a flat faster than a person can walk. Fence and grate every opening, never work in a sluice without the gate pinned shut and a watcher above, and always leave yourself more time to get off the flats than you think you need (Life Jackets, Lifebuoys and Lifeboats).

  • Warm fresh water carries a brain-infecting amoeba. In warm springs and warm ponds, water forced up the nose can carry an organism that causes an almost always fatal infection. Keep your head above water, do not dive or jump in, and do not let children splash water into each other's faces. Swallowing the water does not pass on this infection; it is the nose that matters.
  • Geothermal water is often poisonous to drink and to crops — arsenic, boron, fluoride, mercury and salt are common in it. Test it on plants before irrigating, and never pipe it into a drinking supply (Water Treatment for a Town).
  • A dam that fails empties on whatever is behind it. Build the core, spillway and toe drain as Dams and Reservoirs says and inspect after every spring tide and storm.
  • Steam and pressure. A geothermal well or separator is a boiler without a firebox: the relief valves, gauges and discipline of Boilers and Pressure Vessels apply exactly. Pumping water into hot rock at depth has also set off earthquakes big enough to damage buildings.

What this unlocks

Steady heat frees a settlement from the woodpile and grows glasshouse food in winter (Cold Frames, Cloches and Greenhouses). A tide mill grinds grain and saws timber where there is no stream at all (Sawmills and Lumber). Any of these turning a The Generator feeds the Power Lines and Distribution, and tidal power, predictable but coming in bursts, pairs well with Storing Energy. The pipework, heat exchangers and low-temperature turbines here are those of Solar Heat and Heat Pumps and District Heating.

How it was first done

People bathed in hot springs before history; the Romans built a bath house on the spring at Bath in Britain about AD 70. At Chaudes-Aigues in France, spring water ran through wooden pipes to heat houses from the 1300s — the first district heating anywhere. Reykjavík began heating houses from boreholes in 1930 and now heats nearly the whole city.

Geothermal electricity began at Larderello in Tuscany, where volcanic steam had long been used to boil out boric acid. On 4 July 1904 Prince Piero Ginori Conti ran a small generator on that steam and lit a handful of lamps; a 250 kW commercial plant followed in 1913, and the field still produces power today.

Tide mills are older than almost any other power machine. Excavation at Nendrum monastery on Strangford Lough in Northern Ireland found a tide mill whose timbers were felled in AD 619–621. Tide mills later worked all round the coasts of Britain, France, Spain, Portugal and New England until steam made them obsolete.

Wave power was patented in Paris in 1799, and hundreds of mostly unbuilt patents followed. The lasting success was the Japanese naval officer Yoshio Masuda, whose navigation buoys, worked by an oscillating water column, were used in their thousands from the 1960s. Research after the oil crisis of 1973 — Salter's nodding "duck" (1974), the LIMPET column on Islay (2000), the Pelamis sea-snake (2004) — has yet to produce a machine that pays for itself.

Source: content/entries/energy/geothermal-tidal-and-wave.md