Medical Oxygen

Who needs extra oxygen and how to tell, how to make it at the bedside with a zeolite oxygen concentrator or in bulk from a liquid-air plant into cylinders, and how to deliver it safely through a regulator, flowmeter, humidifier and nasal cannula. Oxygen saves more children with pneumonia than almost any other hospital treatment, and it also turns small sparks into deadly fires.

Difficulty
●●●●●
Time
Minutes to set up a patient on oxygen; a week to make and test a batch of zeolite; one to three months to build and tune a concentrator; a cylinder-filling station follows a working liquid-air plant
Steps from zero
52 prerequisites →

You need first

Liquid Air, Nitrogen and the Noble GasesPressure Vessels and Valves

This unlocks

Breathing Machines and Ventilators
The full path from nothing — 52 steps before this one
  1. Stone Tools
  2. Cordage and Rope
  3. Fire
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Basic Woodworking
  7. Hunting and Trapping
  8. Charcoal
  9. Pottery
  10. The Kiln
  11. Hides and Leather
  12. Salt
  13. Lime
  14. Bricks
  15. Mercury
  16. Fermentation
  17. Lye and Potash
  18. The Wheel and Axle
  19. Glass
  20. Firebrick and Refractories
  21. Bellows
  22. The Lathe
  23. Gears
  24. Iron (the Bloomery)
  25. Copper Smelting
  26. Laboratory Glassware
  27. Pumps
  28. The Waterwheel
  29. Blacksmithing
  30. The Blast Furnace and Cast Iron
  31. The Battery
  32. Magnets
  33. The Barometer
  34. Steel
  35. Sheet Metal and Rolling
  36. The Steam Engine
  37. Bellows to Air Compressors
  38. Electrolysis
  39. Copper Wire
  40. Hydrogen, Oxygen and Gases
  41. Machine Tools
  42. Boilers and Pressure Vessels
  43. The Generator
  44. The Electric Arc Furnace
  45. Ammonia
  46. Ice and Refrigeration
  47. Calcium Carbide and Acetylene
  48. Welding
  49. Liquid Air, Nitrogen and the Noble Gases
  50. Metal Pipes and Tubes
  51. Pressure and Vacuum Gauges
  52. Pressure Vessels and Valves
  53. Medical Oxygen

Do them roughly in this order. See it on the tech tree →

Why it matters

Every cell in the body needs a steady supply of oxygen, carried from the lungs by the blood. When the lungs are full of pus (pneumonia), when a newborn struggles to breathe, after a severe asthma attack, in heart failure, after major injury or surgery, or when the blood carries poison such as carbon monoxide, the body runs short. This is hypoxaemia (too little oxygen in the blood). Without help, the brain and heart fail.

Breathing oxygen-rich air keeps most of these patients alive while the body heals. In children's wards in poor countries, reliable oxygen cut pneumonia deaths by about a third. It is needed in Basic Surgery, Anaesthesia, Safe Childbirth, Diving Medicine and Recompression, chronic lung disease, and every hospital and ambulance.

Two routes supply it:

  • The oxygen concentrator, a box with a compressor and two tubes of zeolite that makes 90–96 % oxygen from room air, at the bedside, as long as there is electricity. One unit supplies one adult or several children.
  • Cylinders filled at 99.5 % purity from a liquid-air plant (Liquid Air, Nitrogen and the Noble Gases) or from water electrolysis (Hydrogen, Oxygen and Gases). They need no power at the bedside and give high flows, but must be carried back and forth for refilling.

How it works

Air is 21 % oxygen. Damaged lungs load the blood poorly, but if each breath holds 30–40 % oxygen, more crosses into the blood. That is all oxygen therapy does. It does not help a patient who is not breathing (they need breaths given, Emergencies) or whose blood is not circulating.

The concentrator uses zeolite, a mineral full of tiny channels about the size of a gas molecule. Squeezed to about 2 bar, certain zeolites grab nitrogen molecules and hold them much more strongly than oxygen. Push compressed air through a tube of zeolite, and nitrogen stays behind while oxygen (and the 1 % of argon in air) comes out the far end. When the zeolite is full of nitrogen, let the pressure out: the nitrogen comes off again and blows away. Two tubes take turns, one making oxygen while the other is emptied. This is pressure swing adsorption (adsorption: gas sticking to a surface).

Air in filter Oil-free compressor 2–2.5 bar Cooling coil Four-way valve swaps beds every 5–10 s Nitrogen out through silencer Bed A: under pressure zeolite holds nitrogen, oxygen passes Bed B: vented nitrogen comes off and is swept out Sieve beds 8–10 cm × 45–50 cm, 1.5–2.5 kg of zeolite beads each Check valves Purge orifice about 1 mm Product tank 2–4 L Regulator, flowmeter 90–96 % to patient
Fig. 1 The oxygen concentrator. The compressor pushes filtered air through one sieve bed while the other vents to the room. Oxygen passes the check valve into the product tank; a small bleed through the purge orifice sweeps nitrogen out of the bed that is venting. Every 5–10 seconds the valves swap the beds.

Who needs oxygen, and how much

Signs of too little oxygen, when you have no instrument:

  • Blue lips and tongue (central cyanosis). Look in daylight. It is a late sign, and hard to see in anaemic patients.
  • Fast breathing: in children, 60 or more breaths a minute under 2 months, 50 or more at 2–12 months, 40 or more at 1–5 years; in adults over 30. Count a full minute while the patient is calm (Examining a Patient).
  • Chest drawing in below the ribs with each breath; grunting; nostrils flaring; the head bobbing with each breath in babies.
  • Unable to drink or feed, confused, restless or very drowsy.

A pulse oximeter clips onto a finger and shines red and infrared light through it; blood rich and poor in oxygen absorb them differently, so it reads the saturation (SpO₂, how full of oxygen the blood is). Building one needs light-emitting diodes, a photocell and a small computer (Pulse Oximeters and Patient Monitors).

Patient Give oxygen if SpO₂ below Aim for
Most adults and children 90–94 % 94–98 %
Chronic lung disease that raises carbon dioxide (old smokers with long-standing breathlessness) 88 % 88–92 %
Premature babies 90 % 90–95 %, never higher for long
Carbon monoxide poisoning, a diver with the bends Always As much as possible (Diving Medicine and Recompression)

Without an oximeter, give oxygen to anyone with central cyanosis, to a child with severe chest indrawing or who cannot feed, and to every case of shock or major bleeding, at the lowest flow that turns the lips pink and slows the breathing. Most patients need it for days, not weeks; check twice a day whether they can come off it.

What you need

Item For See
Oil-free compressor, 40–60 litres of air a minute at 2–2.5 bar Concentrator Bellows to Air Compressors
Zeolite 5A or 13X beads, 3–5 kg Concentrator Below
Two steel or aluminium tubes 8–10 cm × 45–50 cm, product tank 2–4 litres Concentrator Metal Pipes and Tubes
Three-way valves and a timer (cam or relay), check valves Concentrator Pressure Vessels and Valves, The Relay Computer
Seamless cylinders, valves, a filling manifold Cylinders Pressure Vessels and Valves, Alloy and Stainless Steels
Brass, bronze or copper for every fitting; no oil or grease Regulators, flowmeters Zinc and Brass
Glass tube, small balls, needle valves Flowmeters Laboratory Glassware
Soft rubber or plastic tube 3–6 mm Cannulas, tubing Rubber, Petrochemicals and Modern Plastics
Pressure gauges Everywhere Pressure and Vacuum Gauges

The oxygen concentrator

Making the zeolite

Natural zeolites (Water Softening and Ion Exchange) separate air poorly. A concentrator needs a synthetic zeolite: zeolite 5A (calcium form of zeolite A, the easier one to make) or zeolite 13X (sodium form of zeolite X, which works better and was the standard for decades). Expect several trial batches before you get one that works.

Zeolite A from kaolin. This route uses only clay and caustic soda.

  1. Metakaolin. Fire pure white kaolin (Finding and Preparing Clay) at 650–750 °C (dull red) for 2–3 hours. It loses its water and becomes reactive "metakaolin". Grind to flour.
  2. React. In a lidded iron or stainless pot, stir 1 kg of metakaolin into 10 litres of caustic soda solution of about 120 g per litre (3 molar, Lye and Potash). Let it stand at room temperature for a day, stirring now and then (the "ageing").
  3. Crystallise. Heat to 90–95 °C, just below boiling, lid on so it does not dry out, for 6–12 hours without stirring. A fine white powder settles.
  4. Wash the powder with clean water until the wash water is only faintly slippery (pH about 10), then dry at 110 °C.
  5. Make 13X instead by adding Water Glass (Sodium Silicate) to the mix so there is roughly 1.5–2 times as much silica as for A: it gives zeolite X. Its window of recipe and temperature is narrower; try small batches.

Too-strong caustic, too hot or too long turns the crystals into sodalite, a useless cousin. If a batch fails the water test below, change one thing at a time.

Turn A into 5A. Soak the powder in a solution of calcium chloride, about 110 g per litre (from limestone and Hydrochloric Acid), 5 litres per kg, for 4 hours, stirring; pour off; repeat twice; rinse. Calcium takes the place of most of the sodium and opens the channels wide enough to hold nitrogen well.

Beads. Mix 80 parts zeolite powder with 20 parts fine kaolin and a little water into a stiff dough. Roll it into beads 1.5–2.5 mm across by tumbling crumbs in a slowly turning drum, sprinkling powder and spraying water, then sieve to size. Dry at 110 °C, then fire at 550–600 °C for 2–3 hours to set the clay binder. Store hot, sealed in tins.

Water test. Weigh a sample hot from firing, leave it in damp air for two days, and weigh again. Good zeolite A takes up about 20–25 % of its own weight of water; sodalite and unreacted clay take up a few percent.

Warning Water poisons zeolite. Damp beads hold water in place of nitrogen and stop working. Fill the sieve beds with beads freshly baked at 350–400 °C and still warm, sealed from the air.

Building it

  1. Compressor. It must be oil-free: oil vapour in the beds ruins them, and oil in an oxygen line can catch fire. Use a piston compressor with rings of graphite or PTFE (Packing, Gaskets and Seals) or a rubber-diaphragm pump, driven by an The Electric Motor of about 300–400 W for a 5 litre-a-minute unit. It needs roughly 10 times as much air as the oxygen you want: 40–60 litres a minute at 2–2.5 bar.
  2. Intake. A felt and cloth filter, then a small cooling coil of copper tube with fins, so the air reaching the beds is near room temperature. Warm beds hold less nitrogen.
  3. Sieve beds. Two tubes 8–10 cm across and 45–50 cm long, each holding 1.5–2.5 kg of beads, pressed down firmly with a spring and a perforated plate at each end so the beads cannot rattle and grind to dust. Felt pads at both ends stop dust escaping.
  4. Valves. A four-way valve (or two three-way valves) connects the compressor to one bed while venting the other to the room through a silencer (a can of felt). Drive it with a cam on a slow geared motor, or a relay timer (Motor Starters, Contactors and Protection). Each half-cycle lasts 5–10 seconds.
  5. Outlet. From the top of each bed, a check valve lets oxygen into the product tank (2–4 litres) but not back. Between the two bed tops, a purge orifice, a hole about 1 mm across in a brass plug, lets a little oxygen flow back into the venting bed and sweep out its nitrogen.
  6. Output. From the product tank, a regulator to about 0.5 bar, a flowmeter, a fine cloth or paper bacteria filter, and the outlet nipple.

Tuning. Run it for an hour, then test the purity (below) at the flow you need. Too little oxygen: lengthen or shorten the cycle (try 6, 8, 10 seconds), change the purge hole size, and check for leaks with soapy water. Higher flow lowers purity: a unit that gives 93 % at 3 litres a minute may give 85 % at 5.

Testing purity

Steel wool test. Rinse a 1–2 g pinch of steel wool in vinegar to remove oil. Fill a graduated glass tube with the gas by water displacement (Hydrogen, Oxygen and Gases), push the wet wool up into its top, and stand the tube mouth-down in a dish of water. Iron rusting eats the oxygen; over one to two days the water rises. The fraction of the tube it fills is the fraction of oxygen. Air fills about a fifth; good concentrator oxygen, nine-tenths.

Quick check. A glowing splint bursts into flame in gas over about 60 % oxygen. It tells you the unit works, not how well.

A good concentrator gives 90–96 % steadily for 8 hours, starts within 5 minutes, and keeps its purity month after month. Purity that falls slowly over weeks means damp or dusty beads: replace or re-bake them.

Oxygen cylinders

The cylinder itself, its seamless forging, valve, stamping and testing, is in Pressure Vessels and Valves. Medical oxygen cylinders follow those rules, with three more:

  • Mark them. Paint the shoulder white (the international code; some countries use green) and stamp "OXYGEN". Never use a cylinder that has held any other gas.
  • Keep the fitting unique. Small cylinders carry a pin-index valve: two pins on the regulator yoke (oxygen uses positions 2 and 5) fit two holes in the valve face, so a regulator for another gas cannot be fitted. Large ones have their own thread.
  • Clean. Before first use, wash inside with hot soda solution, rinse, and dry with warm oxygen or nitrogen. Never let oil or grease in.

How long it lasts. Litres of gas = water capacity (litres) × pressure (bar). A 10-litre cylinder at 200 bar holds 2,000 litres; at 2 litres a minute that is about 16 hours; at 15 litres a minute, about 2. A 47-litre cylinder at 150 bar holds 7,000 litres, about 2½ days for one patient at 2 litres a minute. Change at about 15 bar, never run dry: moist air gets in and the cylinder rusts.

Filling from a liquid-air plant

Liquid oxygen tank vacuum-jacketed; vent always open Cold pump raises the liquid to 150–200 bar; gauge on the outlet Finned vaporiser liquid boils and warms to gas Manifold gauge Safety valve Copper pigtails with a valve and non-return valve Cylinders white shoulder Cold water trough: fill slowly, 20–30 minutes
Fig. 2 A cylinder filling station. A cold pump lifts liquid oxygen from the storage tank to 150–200 bar; it warms back to gas in the finned vaporiser and fills a row of cylinders on the manifold, standing in a water trough to keep them cool.

The safest way to fill cylinders is to pump the oxygen while it is liquid, then let it warm. Pumping liquid takes far less work than compressing gas and nothing gets hot.

  1. Storage. Liquid oxygen of 99.5 % purity from the column (Liquid Air, Nitrogen and the Noble Gases) goes into a vacuum-jacketed tank like a big dewar (Cryogenics and Superconductors), with a safety valve and a vent.
  2. Cold pump. A small piston pump of stainless steel or bronze, its cylinder sunk in the liquid, with packings of PTFE or graphite, raises the liquid to 150–200 bar.
  3. Vaporiser. The high-pressure liquid passes through a long coil of finned copper or stainless tube in open air (or in a water bath). It boils and warms to room temperature. Frost on the coil is normal; frost reaching the outlet means you are pumping too fast.
  4. Manifold. A heavy pipe with 6–10 flexible copper "pigtails", each with its own valve and a non-return valve, each screwed to one cylinder. A pressure gauge and a safety valve set a little above filling pressure.
  5. Before filling check every cylinder: test date within limits, no dents, burns or arc marks, valve sound. Tap it with a small hammer; a clear ring means sound, a dull thud means corrosion or a crack inside. Vent what is left, sniff it: any smell means contamination, so set it aside for cleaning.
  6. Fill slowly, over 20–30 minutes, with the cylinders standing in a trough of cold water or sprayed, so none gets too hot to hold a hand on (over about 50 °C). Close valves, cool, check the pressure again, and test every valve for leaks with clean soapy water, then rinse.
  7. Test one cylinder from each batch for purity and record it. Label the batch and date.

Without a liquid-air plant, oxygen from water electrolysis (Electrolysis, Hydrogen, Oxygen and Gases) is pure enough. Wash it through water, dry it through silica gel (Water Glass (Sodium Silicate)), and compress it with an oil-free, water-lubricated compressor in three or four stages, cooled between each. Do not use oxygen from heating saltpeter for breathing (Diving Medicine and Recompression).

Regulator, flowmeter and humidifier

Regulator cylinder pressure down to 3.5–4 bar Spring and setting screw Diaphragm Seat PTFE pad Sintered filter no oil anywhere Needle valve after the tube Flowmeter read at the middle of the ball Bubble humidifier boiled water; wash daily Tubing 1.5–2 m Nasal cannula prongs sit just inside the nostrils 1.5 cm 1 cm tubes over the ears, toggle under chin
Fig. 3 Delivering oxygen. The regulator's spring and diaphragm drop cylinder pressure to about 4 bar. The needle valve sets the flow; the ball in the tapered flowmeter tube rises until gas slips past it, and is read at its middle. The gas bubbles through water and reaches the nose through soft prongs.

Oxygen regulator

The oxygen regulator cuts cylinder pressure (up to 200 bar) to a steady 3.5–4 bar whatever the cylinder still holds.

  1. Body: forged or cast brass or bronze, with a yoke for pin-index valves or a nut for large cylinders, and a sealing washer of PTFE or fibre (never rubber at the high-pressure side).
  2. Inlet filter: a disc of sintered bronze or fine brass gauze. A grain of grit thrown at high speed can strike sparks in pure oxygen.
  3. Seat: a small brass nozzle closed by a nylon or PTFE pad.
  4. Diaphragm: thin brass, or rubber-proofed cloth on the low-pressure side, about 5 cm across, pushed down by a spring that holds the pad open. When outlet pressure rises, it lifts the diaphragm and closes the seat; when gas is drawn off, the spring opens it again. Turn the spring screw to set the outlet pressure.
  5. Safety valve on the low side, opening at about 7 bar, and a contents gauge on the high side (Pressure and Vacuum Gauges).

Good or bad. Outlet pressure stays within half a bar from a full cylinder to a nearly empty one. If the outlet pressure creeps up with no flow, the seat leaks: replace the pad. Never oil it.

Flowmeter

A flowmeter shows how many litres a minute go to the patient.

  • Ball-in-tube (Thorpe tube): a glass tube 15–20 cm long whose bore widens slightly upward, with a light ball of glass, steel or hard plastic inside. Gas entering at the bottom lifts the ball until the gap around it is just big enough to let the flow through. Make the tapered tube by heating thick glass tubing over a polished, tapered steel rod (mandrel) while sucking the air out from inside, so the soft glass shrinks onto the rod; then slide the rod out (Scientific Glassblowing and Glass-to-Metal Seals). The needle valve that sets the flow goes after the tube, so the tube works at the steady 4 bar and reads true.
  • Fixed-orifice selector: simpler. A brass disc with a ring of holes of different sizes turns in front of the outlet. At a fixed 4 bar, each hole passes a fixed flow. Drill the holes, then mark each with its measured flow.
  • Calibrating: fill a 1-litre bottle with water, turn it upside-down in a basin, and lead the tube under its mouth. At 1 litre a minute the bottle empties in 60 seconds; at 2, in 30. Mark the tube or disc at each flow.

Children need fine control: a separate low-flow meter reading 0–2 litres a minute in steps of 0.1–0.25. A flow splitter, a brass block with one inlet and four outlets, each with its own needle valve and small flowmeter, lets one concentrator supply several children.

Bubble humidifier

Dry oxygen at high flow dries the nose and thick mucus. A bubble humidifier is a clear jar with a screw lid, a tube from the lid to near the bottom ending in a perforated nozzle, and an outlet from the space at the top. Fill to the mark with boiled, cooled water. Use it for flows over about 4 litres a minute in adults, and always with a nasal catheter. Children on prongs at low flows do not need one. Empty, wash and boil it every day: dirty humidifiers grow bacteria that cause pneumonia.

Giving oxygen to the patient

Nasal cannula

The nasal cannula (nasal prongs) is the best everyday way to give oxygen: comfortable, cheap, and the patient can eat and talk.

  • Make the tubing of soft rubber or plastic, 3–4 mm bore, 1.5–2 m long, by dipping a greased smooth rod repeatedly in latex (Rubber) or extruding plastic.
  • The face piece: a short length of slightly wider tube, closed at both ends, with two holes punched 1.5 cm apart (1 cm for babies). Push in two prongs of soft tube about 1 cm long for adults (0.5 cm for newborns), glued with rubber cement. The tubing joins both ends of the face piece and runs back over each ear to a sliding toggle under the chin.
  • Fit: the prongs sit just inside the nostrils, and must not fill them; air should flow around them. Tubes loop over the ears; the toggle snug but not tight.
  • Good or bad: soft, smooth, no sharp edges at the cut prong ends, the tubing does not kink when bent double. Wash and boil between patients.

Nasal catheter. A soft tube of about 8 French (2.7 mm), with a few side holes near the tip, passed gently along the floor of one nostril for the distance from the side of the nose to the inner end of the eyebrow, and taped. Use when prongs are not available. Always humidify, and change it to the other nostril twice a day.

Face masks. A simple soft cup over nose and mouth, at 5–10 litres a minute (less lets breathed-out carbon dioxide build up). For the highest oxygen, a mask with a reservoir bag and one-way valves at 10–15 litres a minute, as made in Diving Medicine and Recompression. Masks, airways and suction for an unconscious patient are in Airway Equipment: Laryngoscopes and Tubes.

How much flow

Device Flow (litres a minute) Oxygen breathed, roughly
Prongs, newborn 0.5–1
Prongs, infant 1–2
Prongs, child 1–4
Prongs, adult 1–6 About 24 % at 1, plus 4 % per litre: 40 % at 5
Simple mask 5–10 35–55 %
Mask with reservoir bag 10–15 60–90 %

Start at the low end, watch for 15 minutes, and raise the flow step by step until the signs improve or the saturation is in range.

How to tell it worked

  • Lips and tongue turn pink, breathing slows and eases, a child starts feeding and a confused adult becomes clearer, within 15–30 minutes.
  • An oximeter shows the target saturation.
  • The concentrator's output fills nine-tenths of the steel wool tube; the cylinder gauge falls at the rate you calculated.

Note Troubleshooting. No flow from the prongs → check the tube for kinks; dip the prongs in water and look for bubbles. Concentrator purity falling → damp or dusty beads, a leaking check valve, a clogged intake filter, or a hot room. Clean the filter weekly; re-bake or replace the beads. Patient no better on oxygen → airway blocked (suck out mucus), oxygen not reaching them (check the whole line), or they need more than oxygen: fluids, antibiotics, breaths given. See Emergencies. Patient sleepier on oxygen → in chronic lung disease, too much oxygen can let carbon dioxide build up. Turn the flow down to 1–2 litres a minute and watch closely.

Dangers

Danger Fire. Oxygen does not burn, but in oxygen-rich air everything else burns violently. Hair, bedding and clothing soaked with oxygen catch fire from a spark or a cigarette and burn in seconds, and patients have died with burns of the face from smoking while on oxygen. No smoking, candles, oil lamps or open fires within 3 metres of oxygen in use. Turn the oxygen off when not in use. Keep rooms aired. After a patient comes off oxygen, let clothing and bedding air for half an hour before going near a flame.

Danger Oil and grease explode in pure oxygen. Never oil a regulator, valve or fitting; never handle them with greasy hands; never use petroleum jelly on the lips or nose of a patient on oxygen (use a water-based cream). Open a cylinder valve slowly, standing to one side of the regulator: suddenly compressed oxygen heats enough to ignite a seat or washer.

Danger Cylinders are pressure bombs. A cylinder with its valve knocked off flies like a rocket. Chain or strap every cylinder upright to a wall or trolley, keep the valve cap on when moving it, and keep cylinders away from heat and sun.

  • Too much oxygen hurts some patients. In premature babies, high oxygen for days damages the retina and causes blindness (retinopathy). Keep their saturation no higher than 95 %. In chronic lung disease, high flows can make the patient drowsy and stop breathing. Breathing over 60 % oxygen for more than a day or two can inflame healthy lungs.
  • Electrical. A concentrator runs for days; build it with a fuse, earthed casing, and wiring sized for the motor (Wiring and Electrical Safety).

What this unlocks

Reliable oxygen makes long Anaesthesia and major Basic Surgery safer, keeps premature babies and children with pneumonia alive, and treats divers (Diving Medicine and Recompression) and carbon monoxide poisoning. With mechanical Breathing Machines and Ventilators, made from the same valves, compressors and timers, it lets a hospital care for patients who cannot breathe for themselves.

How it was first done

Oxygen was discovered by Carl Wilhelm Scheele in Sweden around 1771–72 and by Joseph Priestley in England in 1774; Antoine Lavoisier named it. Cheap oxygen first came from the Brin process (heating barium oxide, from 1886) and then from Carl von Linde's liquid-air plants from 1902. John Scott Haldane showed during the First World War that oxygen saved soldiers poisoned by gas, and published the first scientific account of oxygen therapy in 1917. Oxygen tents spread in the 1920s and nasal cannulas by mid-century. In 1980–81 two large trials in the United States and Britain showed that people with chronic lung disease lived longer on oxygen for 15 hours or more a day. Synthetic zeolites, first made at Union Carbide in the late 1940s, and the pressure swing cycle patented by Charles Skarstrom in 1960, led to the home oxygen concentrator in the 1970s. In Papua New Guinea from the early 2000s, solar- and mains-powered concentrators in district hospitals cut child pneumonia deaths by about a third.