Part 10 · Machines
Pressure and Vacuum Gauges
How to measure the pressure in a boiler, a pump, a gas main or a vacuum line. A bent glass tube of water or mercury reads low pressures directly; a curved, flattened metal tube that straightens under pressure turns a pointer for high ones. How to build both, calibrate them against a mercury column and a loaded piston, and fit and trust them on boilers, pumps and vacuum work.
- Difficulty
- ●●●●●
- Time
- An hour for a water U-tube; two to three weeks for a Bourdon gauge and a dead-weight tester
- Steps from zero
- 34 prerequisites →
This unlocks
Pressure Vessels and ValvesThe full path from nothing — 34 steps before this one
- Fire
- Cordage and Rope
- Stone Tools
- Finding and Preparing Clay
- Finding and Identifying Ores
- Hunting and Trapping
- Basic Woodworking
- Charcoal
- Pottery
- The Kiln
- Hides and Leather
- Bricks
- Lime
- Mercury
- Lye and Potash
- The Wheel and Axle
- Firebrick and Refractories
- Glass
- Bellows
- Gears
- Iron (the Bloomery)
- Copper Smelting
- Laboratory Glassware
- The Waterwheel
- Blacksmithing
- Magnets
- The Barometer
- Sheet Metal and Rolling
- Copper Wire
- The Generator
- The Electric Arc Furnace
- Calcium Carbide and Acetylene
- Welding
- Metal Pipes and Tubes
- Pressure and Vacuum Gauges
Do them roughly in this order. See it on the tech tree →
Why it matters
You cannot see pressure, and guessing it kills. A boiler that is "probably fine" at a pressure nobody can read is how boilers explode. A pump whose delivery pressure is unknown cannot be matched to its pipes; a vacuum line that is "pumped down" may still hold enough air to ruin a The Light Bulb or a The Vacuum Tube.
A pressure gauge turns pressure into a number you can read from a distance, write in a log, compare with yesterday's and with the safety limit. With gauges you can:
- run a The Steam Engine and its boiler at a known, safe pressure, and notice when something changes;
- set a safety valve to lift at the right pressure (Boilers and Pressure Vessels);
- test pipes, boilers and pressure cookers before use (Pipes, Plumbing and Aqueducts, Metal Pipes and Tubes);
- measure the work of a Pumps or compressor, and the vacuum of a The Vacuum Pump;
- check the draught of a chimney or furnace (Chimneys, Stoves and Heating), the gas pressure in a town main (Natural Gas and Helium), or the air in a tyre (The Bicycle, The Motor Vehicle).
How it works
Pressure is force spread over an area. Units you will meet:
| Unit | Equal to | Feel |
|---|---|---|
| 1 bar | 100,000 pascals (Pa) = 100 kPa | About 1 kg pressing on each square centimetre; very close to the air's pressure at sea level |
| 1 atmosphere | 1.013 bar = 760 mm of mercury | The air's average pressure at sea level (The Barometer) |
| 1 mm of mercury (mm Hg) | 133 Pa | Used for vacuum and blood pressure |
| 1 mm of water | 9.8 Pa | Used for chimney draught and gas mains |
| 1 pound per square inch (psi) | 6.9 kPa; 14.5 psi = 1 bar (Units, Conversions and Mathematical Tables) | Old English-speaking gauges |
A column of liquid balances a pressure. A pressure that holds up a column of liquid h tall equals the weight of that column per unit area. So:
- 10 m of water ≈ 1 bar. Each metre of water is 0.1 bar.
- 750 mm of mercury ≈ 1 bar. Mercury is 13.6 times heavier than water.
This is exact and needs no calibration: a liquid column is the master gauge. All other gauges are checked against it.
Gauge pressure and absolute pressure. Most gauges read the difference from the surrounding air. A tyre "at 2 bar" holds 2 bar more than the air, about 3 bar absolute. A vacuum gauge reads how far below the air a vessel is, at most about 1 bar (760 mm Hg) when the vessel is perfectly empty. Absolute pressure = gauge pressure + barometer reading.
The Bourdon tube. Take a metal tube, flatten it so its cross-section is an oval, and bend it into a curve like the letter C, sealed at one end. When pressure is let in, it tries to make the oval round again. A round tube cannot stay curved as tightly as an oval one, so the curve opens out, and the sealed tip moves a few millimetres. The movement is nearly proportional to the pressure. A little gearing turns those millimetres into a pointer sweeping three-quarters of a dial. Under vacuum the tube curls tighter and the tip moves the other way.
What you need
| Item | For | Notes |
|---|---|---|
| Glass tube, 5–8 mm bore, 1–2 m | U-tube manometers | Even bore, straight (Laboratory Glassware) |
| Mercury, 0.5–2 kg | Mercury manometer and calibration column | Distilled from cinnabar (Mercury); poisonous |
| Water with a little dye | Low-pressure manometers | Ink or a pinch of a plant dye (Dyes and Mordants) |
| Thin-walled brass or copper tube, 6–10 mm across, 0.3–0.6 mm wall | Bourdon tube | Drawn tube (Metal Pipes and Tubes, Iron and Brass Wire) |
| Lead or a low-melting alloy | Filling the tube while bending | Lead, Antimony and Bismuth |
| Brass bar and sheet | Socket, movement, case | Zinc and Brass, Sheet Metal and Rolling |
| Fine steel or brass for a hairspring | Taking up slack in the movement | Springs |
| Silver solder | Joining tube to socket | Soldering and Brazing |
| Castor oil or clean plant oil | Dead-weight tester | Oils and Pressing |
| A lathe | Socket, pinion, piston and cylinder | The Lathe, Machine Tools |
| Weights | Dead-weight tester | Checked on a good balance (Measurement from Scratch) |
Method 1: The U-tube manometer
The simplest, most trustworthy gauge. Use it for anything up to about 2 bar with mercury, or up to about 0.2 bar with water.
- Bend the tube. Heat a 1.2 m length of glass tube in the middle in a broad flame, turning it all the time, until it sags. Bend it slowly into a U with legs 10–15 cm apart, keeping the bore round (Laboratory Glassware). Legs of 50 cm suit a water gauge; for mercury up to 1 bar you need legs of about 80 cm.
- Mount it upright on a board, with a scale in millimetres between the legs, zero at the middle. Use a plumb line to set the board vertical: a slanting U-tube reads wrong.
- Fill it half full: dyed water for low pressures, mercury for high. Both levels should stand at zero. If not, slide the scale.
- Connect one leg, through a tap, to the thing being measured, with rubber or lead pipe. Leave the other leg open to the air.
- Read the height of each surface and add them: the difference in level, h, is the pressure. Read water at the bottom of its curved surface, mercury at the top. Reading both legs makes the gauge independent of small differences in bore.
pressure (Pa) = h (mm) × 9.8 for water; × 133 for mercury
Example: A furnace's draught pulls the water 12 mm up one leg and 12 mm down the other: h = 24 mm of water = 235 Pa — a good strong draught. A gas main pushes h = 120 mm of water: 1.2 kPa.
The trap. Put a bulb or a closed bottle at the top of the open leg (with a small hole to the air). If the pressure suddenly jumps, the liquid is thrown into the bulb instead of across the room.
The well-type gauge. For a single reading leg, replace one leg with a wide pot. The level in the pot hardly moves, so you read one leg only; mark the scale a few percent short to allow for the pot's small drop.
The inclined manometer reads tiny pressures. Tilt the reading leg of a well-type gauge to a slope of 1 in 10. The liquid now moves 10 mm along the tube for every 1 mm it rises. With water, each millimetre along the tube is about 1 Pa. Use it for chimney draughts, ventilation and the air in mines.
A mercury column for higher pressure. An open mercury tube 1.6 m tall, with its foot in a closed iron pot of mercury connected to the boiler, reads to 2 bar. Early steam engines used exactly this. It is the best calibration standard for your other gauges below 2 bar; for everyday use the Bourdon gauge is safer and handier.
Method 2: The Bourdon gauge
For steam boilers, compressors and water mains, where a glass tube would be broken or blown out. A good 100 mm dial gauge, for 0–10 bar, is described here; scale the parts for other sizes.
The tube
- Choose the tube. Brass or phosphor bronze, about 8 mm across and 0.4 mm wall, 30 cm long. Thinner walls and flatter ovals make a gauge more sensitive but weaker: for 0–2 bar use 0.3 mm wall and flatten more; for 20 bar and above use 0.6–1 mm wall, steel, and flatten less.
- Anneal it by heating to a dull red and quenching (brass and copper are soft after this).
- Flatten it evenly to an oval about 12 mm by 3.5 mm, by rolling it between two smooth rollers or pressing it in a vice between two polished steel bars. It must be even along its whole length, with no kinks.
- Fill it with molten lead or a low-melting alloy, or with tightly rammed fine dry sand, and plug the ends. The filling stops the tube collapsing as you bend it.
- Bend it around a hardwood or iron former of 25–30 mm radius, with the flat sides facing the former and the outside, through about 270° (three-quarters of a circle). Bend slowly and evenly.
- Empty it by heating to melt out the metal (or shake out the sand), clean it with acid and hot water, and anneal again lightly.
- Seal the tip by flattening its last 5 mm and soldering it shut, with a small brass tip block drilled for a pin.
- The socket. Turn a brass block on the lathe with a threaded stem underneath to screw into the boiler fitting, and a drilled passage up to the tube. Silver-solder the open end of the tube into the socket (Soldering and Brazing). Test it under water with air pressure for leaks.
The movement
The tip moves only about 3–5 mm at full pressure. The movement multiplies that into a pointer swing of 270°.
- The best way: sector and pinion. A light link joins the tip to an arm on a toothed sector (a slice of a gear wheel) pivoted on the socket plate. The sector meshes with a small pinion of about 12 teeth on the pointer spindle. With a sector of 20 mm radius, a pinion 3.6 mm across (gearing up about 11 times) and the link fixed about 9–10 mm from the sector's pivot, a 4 mm movement of the tip swings the pointer about 270°. Cut the fine teeth as in Gears and Watches and Small Clocks.
- A simpler way: thread and drum. A fine silk thread runs from the tip, wraps once round a small drum, 3 mm across, on the pointer spindle, and is kept taut by a light coiled spring. A 5 mm movement of the tip turns a 3 mm drum through 5 ÷ (3.14 × 3) × 360 ≈ 190°. It is less robust but needs no gear cutting.
- The hairspring. A fine flat spiral spring on the pointer spindle, like a watch's but weaker, keeps every tooth pressed one way and takes up the slack (Springs). Without it the pointer wobbles and sticks.
- Adjust the swing by moving the link along a slot in the sector arm: further out gives less swing, further in more.
Dial and case
Mount the movement on a brass plate behind a round dial of enamelled metal or varnished card, 100 mm across. The scale is not marked from theory: mark it from the calibration below. Put a stop pin at zero so the pointer cannot be bent backward, a glass front, and a case. Leave the back of the case thinner than the front, or cut a blow-out disc into it: if the tube bursts, the case should burst backward, not throw glass forward into a face.
Vacuum and compound gauges
The same gauge reads vacuum if you set the pointer's zero at the other end of the dial: under vacuum the tube curls tighter. Mark it 0 to 760 mm Hg of vacuum (or 0 to −1 bar). A compound gauge has zero partway round and reads both pressure and vacuum: it is the gauge for a pump's suction side and for a steam engine's condenser. For better vacuum than about 10 mm Hg, use the mercury gauges in The Vacuum Pump; for the far lower pressures of tubes and bulbs, see the gauges in High-Vacuum Pumps and Gauges.
Method 3: Calibrating
A gauge is only as good as its last check. Calibrate every new gauge, and check working gauges every few months.
Against the mercury column (up to 2 bar)
- Connect the new gauge and an open mercury column, side by side, to a closed vessel full of water.
- Raise the pressure in steps: a small hand force pump, or a screw pressing a piston into the vessel, or a tall standpipe of water — every 1 m of water adds 0.1 bar.
- At each step, read the mercury column: 750 mm Hg = 1 bar. Mark the gauge's dial where its pointer stands.
- Take readings going up, then coming down. The two should agree within about 1% of full scale; if they don't, the movement is sticking (see the NOTE).
The dead-weight tester (any pressure)
For higher pressures, build a dead-weight tester: a loaded piston whose weight makes an exact pressure.
- Piston and cylinder. Turn a hardened steel piston 11.28 mm in diameter — exactly 1 cm² in area — and a cylinder for it, and lap the two together with fine abrasive and oil until the piston slides in under its own weight but oil escapes only very slowly (Machine Tools, Abrasives and Grinding Stones). No packing: the fit itself seals.
- Body. The cylinder stands upright on a block with an oil passage leading to the gauge connection and to a screw press: a second piston pushed in by a hand screw to raise the pressure.
- Weights. On top of the piston a tray carries brass weights. Every 1 kg on a 1 cm² piston makes 0.981 bar. The piston and tray count too.
- Use. Fill with oil, screw the gauge on, load the weights for the pressure you want, and turn the screw until the weights float, lifted clear of their rest. Spin them gently by hand to free the piston of friction. Read the gauge. That is the true pressure.
Check the piston's area against mercury. At a low load, connect the tester and the mercury column together. If 1.020 kg (piston, tray and weights) floats the piston at exactly 750 mm of mercury, the area is 1.000 cm². Otherwise, area (cm²) = mass (g) ÷ (13.6 × column in cm). This needs no micrometer.
Write a calibration card for each gauge: true pressure against reading, rising and falling. Keep it with the gauge's number in the boiler log.
Fitting gauges to the work
- Range. Pick a gauge whose normal working pressure falls in the middle third of the dial: a 0–16 bar gauge for a boiler working at 8 bar. A gauge that lives near its top end wears out and loses accuracy; one used near zero is hard to read.
- Red line. Paint a red mark at the boiler's maximum working pressure (Boilers and Pressure Vessels).
- Siphon on steam. Fit a gauge siphon (a "pigtail"): a loop of tube, one full turn, between boiler and gauge. Condensed water fills the loop and keeps live steam away from the gauge's soft-soldered joints and its calibration.
- Snubber on pumps. On a piston Pumps or compressor, the pointer jumps with every stroke and wears out the teeth. Put a restriction in the line — a plug with a 0.5 mm hole — or a small tap partly closed.
- Gauge cock. Every gauge gets its own tap so it can be changed without shutting down. Boilers have a second test connection where an inspector screws on a checked gauge to compare.
- Pumps. A gauge on the delivery side reads head: every 1 bar lifts water about 10 m. A compound gauge on the suction side shows how hard the pump is pulling; above about 7 m of suction lift (0.7 bar vacuum), most pumps fail (Pumps).
The tyre pressure gauge
A pocket gauge for tyres: a brass tube 10 mm bore and 10 cm long, with a valve-pressing nozzle at one end. Inside, a piston with a leather cup seal (Packing, Gaskets and Seals) is pushed by the air against a coil spring. The piston pushes a light indicator rod out of the far end; friction holds the rod out when the gauge is taken off. Mark the rod against a calibrated gauge at 1, 2, 3 and 4 bar. An 8 mm piston (0.5 cm²) at 3 bar pushes with 15 N; a spring of about 0.5 N per mm gives a 30 mm movement at 3 bar.
How to tell it worked
- Zero is zero. With the gauge open to the air, the pointer rests exactly at zero. Tap the case: it should not move.
- Up equals down. Readings taken rising and falling agree within 1% of full scale.
- Two gauges agree. On a working boiler, your gauge and the inspector's test gauge read within 2% of full scale.
- It comes back. After a test at full scale, the pointer returns to zero. If it rests above zero, the tube has been overstrained and taken a permanent set; scrap it.
- The U-tube needs no test beyond being upright, clean and correctly read.
Note Troubleshooting. Pointer sticks, then jumps: the teeth are rough or the pivots tight; polish and oil them lightly, and check the hairspring. Reads differently rising and falling: friction or a loose link; tighten the link pin, free the pivots. Pointer never reaches full swing: link too far out on the sector arm; move it in. Pointer swings past the dial at half pressure: link too far in, or the tube too thin and flat for this range. Gauge creeps up slowly at steady pressure: the tube is being strained beyond its limit; use a thicker tube or a higher-range gauge. Reads zero on a live boiler: the gauge cock is shut or the siphon is blocked with scale; trust nothing until this is cleared, and check the water level and safety valve at once. U-tube liquid sticks in drops: the glass is greasy; clean it with soap, then acid and distilled water.
Dangers
Danger A gauge that reads wrong is worse than no gauge. Boilers have exploded with their gauges showing a safe pressure, because a cock was shut, a siphon was choked, or the pointer had been bent. Never rely on one gauge alone: the safety valve must be set and tested by itself (Boilers and Pressure Vessels). If the gauge and safety valve disagree, stop firing and find out why.
Danger Mercury gives off a poisonous vapour, worst when warm and when spilled into cracks. Keep mercury gauges and columns in trays that would catch a spill, in a cool, airy room. Never heat mercury in the open. Gather spills at once with a card and a dropper, never a vacuum or a brush (Mercury).
- A bursting gauge throws glass and metal. Stand to one side of a gauge when first raising pressure, and fit blow-out backs.
- Test with liquid, not air. Water or oil hardly stores energy under pressure; compressed air in a test rig or a boiler stores a great deal and explodes violently if anything fails. Always pressure-test with water or oil (Boilers and Pressure Vessels).
- Live steam through a gauge without a siphon scalds the person who unscrews it. Shut the cock and let it cool first.
Going further
- The diaphragm gauge: a corrugated metal disc that bulges under pressure, used for low pressures and dirty fluids, and in the aneroid The Barometer.
- The recording gauge: a pen on the pointer draws pressure on a paper drum turned by clockwork (The Mechanical Clock), giving a week's record of a boiler or a water main.
- The engine indicator: a small piston and spring connected to an engine cylinder, drawing pressure against piston position. The area of the drawing is the work done each stroke (The Steam Engine).
- Electrical gauges: a pressure-moved diaphragm changes a resistance, so the reading can be sent by wire (Measuring Electricity).
How it was first done
The liquid column came first: Evangelista Torricelli's mercury barometer (1643–1644) and Robert Boyle's J-shaped tube (1662), with which he showed that halving the volume of trapped air doubles its pressure. James Watt fitted mercury gauges to his engines' boilers and condensers in the late 1700s, and his assistant John Southern drew the first engine indicator diagrams about 1796. Tall mercury columns were clumsy and dangerous on high-pressure boilers. In 1849 the French instrument maker Eugène Bourdon patented his curved-tube gauge; it spread quickly through the railways and steamships of Europe, and the American Edward Ashcroft took it up in the United States in the early 1850s. In 1850 Bernhard Schäffer of Magdeburg patented a corrugated diaphragm gauge, and the firm of Schäffer and Budenberg made both kinds. Dead-weight piston testers were in use by the later 1800s, and they remain the standard against which pressure gauges are checked.