◆ Rebuild

Part 8 · Chemistry

pH, Indicators and Buffers

How to measure acidity to a tenth of a unit and hold it where you want it. Make a ladder of reference solutions from weighed borax, cream of tartar, lime and soda; paint them into a colour chart for home-made pH papers; mix buffers that keep a dye bath, cheese vat, eye drop or plating tank at the right pH; and build a pH meter from an antimony rod or a thin glass bulb. Canning safety, blood, soil, dyeing and the laboratory all depend on it.

Difficulty
●●●●●
Time
A day to make the reference ladder and a colour chart; an evening per buffer; a week to build and calibrate a pH meter
Steps from zero
11 prerequisites →

You need first

Acids, Bases and TestingIdentifying Substances

This unlocks

—
The full path from nothing — 11 steps before this one
  1. Fire
  2. Finding and Preparing Clay
  3. Pottery
  4. The Kiln
  5. Lime
  6. Lye and Potash
  7. Fermentation
  8. Glass
  9. Acids, Bases and Testing
  10. Laboratory Glassware
  11. Identifying Substances
  12. pH, Indicators and Buffers

Do them roughly in this order. See it on the tech tree →

Why it matters

Acids, Bases and Testing showed how to tell acid from alkali with cabbage juice, and how strong an acid is by titration. That is enough for soap and soil. Many jobs need more: not "acid" but "pH 4.2, not 4.8", and not just measured once but held there while you work.

This chapter gives you reference solutions to calibrate against, buffers that hold a pH, and pH papers and a pH meter to read it.

How it works

What the number means

In water, acids release free hydrogen ions (hydrogen atoms that have lost their electron). pH counts them on a scale of tens: pH 3 means one-thousandth of a "mole" of hydrogen ions per litre, pH 4 one ten-thousandth, and so on. (A mole is a fixed, very large number of particles; 1 g of hydrogen ions is one mole.) Pure water at 25 °C is pH 7. Each step down is ten times more acid; each step up, ten times less.

Why a weak acid holds the pH steady

A strong acid such as hydrochloric releases all its hydrogen at once. Add a little alkali and the pH jumps. A weak acid such as vinegar holds most of its hydrogen back. Now partly neutralise it with soda, so you have a mixture of the weak acid and its salt (sodium acetate). This mixture is a buffer:

  • add a little strong acid, and the acetate soaks up the hydrogen ions, turning back into weak acetic acid;
  • add a little alkali, and the acetic acid releases hydrogen to neutralise it.

Either way, the pH hardly moves. Even diluting it with water barely changes it, because the ratio of acid to salt stays the same.

The half-neutralisation rule

Every weak acid has its own characteristic number, called its pKa. When exactly half of a weak acid has been neutralised, the pH equals its pKa. Neutralise more or less than half, and the pH shifts:

Fraction of the acid neutralised pH
10 % pKa − 1
25 % pKa − 0.5
50 % pKa
75 % pKa + 0.5
90 % pKa + 1

A buffer works well only within about one unit either side of its pKa. To hold a different pH, choose a different weak acid. (Chemists write this rule as the Henderson–Hasselbalch equation: pH = pKa + log₁₀ of salt ÷ acid.)

024681012140halfall1½ × pH soda added, as a share of what neutralises all the acid Both curves end in excess soda Vinegar (weak) rises slowly; long flat buffer stretch Hydrochloric (strong) no buffering at all: leaps at the end Buffer zone pH stays within ±1 of pKa pKa 4.76 half neutralised
Fig. 1 Why a buffer holds steady. Adding soda to strong acid makes the pH leap at the end point; adding it to a weak acid gives a long, flat stretch centred on the half-neutralised point, where the pH equals the pKa.
Buffer pair pKa Holds pH Made from
Tartaric acid / tartrate 3.0, 4.3 2.5–5 Wine tartar (Citric and Tartaric Acid)
Citric acid / citrate 3.1, 4.8, 6.4 2.5–7 Lemons (Citric and Tartaric Acid) and soda
Acetic acid / acetate 4.76 3.8–5.8 Vinegar and soda
Carbon dioxide / bicarbonate 6.4 5.5–7.5 The buffer of blood
Phosphate (second step) 7.2 6–8 Phosphoric acid from bone ash (Phosphoric Acid and Phosphates) and soda
Boric acid / borate 9.2 8.2–10.2 Borax and boric acid (Borax and Boric Acid)
Ammonium / ammonia 9.25 8.3–10.3 Sal ammoniac and ammonia (Ammonia)
Bicarbonate / carbonate 10.3 9.3–11 Baking soda and washing soda (Soda Ash and Baking Soda)

In practice, buffers of ordinary strength (0.05–0.2 moles per litre) read about 0.1–0.3 lower than the pKa. Check a new buffer against a reference solution.

Indicators

An indicator is itself a weak acid whose two forms have different colours. Its colour changes over about two pH units around its own pKa. Cabbage is unusual: it holds several pigments, so it changes step by step across the whole scale, but only roughly. For tenths of a unit you need indicators with sharp, narrow changes.

Indicator Changes between Colours (acid → alkali) Source
Thymol blue 1.2–2.8 and 8.0–9.6 red → yellow, then yellow → blue Coal-tar dye
Methyl orange 3.1–4.4 red → yellow Coal-tar dye (Coal Tar Chemicals)
Methyl red 4.4–6.2 red → yellow Coal-tar dye
Litmus 4.5–8.3 red → blue Lichen (Acids, Bases and Testing)
Alizarin 5.6–7.2 yellow → red Madder root (Dyes and Mordants)
Bromothymol blue 6.0–7.6 yellow → blue Coal-tar dye
Turmeric 7.4–8.6 yellow → red-brown Turmeric root
Phenolphthalein 8.2–10.0 colourless → pink Phenol and phthalic acid (Organic Synthesis and Fine Chemicals)
Red cabbage 2–12 in steps red → purple → blue → green → yellow Garden

A universal indicator is a mixture of several, chosen so their changes overlap and the colour runs through the rainbow: red (pH 3), orange (5), yellow (6), green (7), blue (9), violet (10). A workable recipe, dissolved in 100 ml of strong spirit (Distillation): 5 mg thymol blue, 12 mg methyl red, 60 mg bromothymol blue, 100 mg phenolphthalein, then drops of dilute lye until it is just green.

What you need

Item Notes
Distilled water, freshly boiled and cooled Carbon dioxide from the air makes plain water about pH 5.6 (Distillation)
Balance weighing to 0.01 g Balances, Steelyards and Weighing Machines, Measurement from Scratch
Graduated flasks and pipettes 100 ml and 1 litre flasks (Laboratory Glassware)
Borax, cream of tartar, slaked lime, washing soda, baking soda Purified by recrystallising (Borax and Boric Acid, Citric and Tartaric Acid, Lime, Soda Ash and Baking Soda)
Vinegar, hydrochloric acid, caustic soda, phosphoric acid Vinegar and Pickling, Hydrochloric Acid, Lye and Potash, Phosphoric Acid and Phosphates
Indicators Plant extracts at first; synthetic dyes when you have them
Filter paper Thick, pure, unsized (Paper)
For the meter Antimony (Antimony and Bismuth), soda-lime glass, silver wire (Gold and Silver), a sensitive voltmeter (Measuring Electricity, Electronic Test Equipment)

Method 1: The reference ladder

You cannot calibrate pH from nothing. You need solutions whose pH is fixed by nature and known. These are the world standards, chosen because each can be made from a weighed, pure substance. Make each in 1 litre of freshly boiled distilled water. Values are at 25 °C (a warm room); within 15–30 °C they change by less than 0.05, except lime water.

pH at 25 °C Solution How to make it
1.1 Hydrochloric acid, 0.1 molar 10.5 ml of 30 % acid made up to 1 litre; check by titration (Acids, Bases and Testing)
2.0 Hydrochloric acid, 0.01 molar 100 ml of the above made up to 1 litre
3.56 Saturated cream of tartar Shake 10 g of pure cream of tartar (potassium hydrogen tartrate) with 1 litre of water for 5 minutes; let it settle; use the clear liquid. Grows mould in days: add a crystal of thymol, or make fresh
4.6–4.7 Acetate, equal parts Below (half-neutralised vinegar)
6.86 Phosphate, equal parts 3.40 g potassium dihydrogen phosphate + 3.55 g dry disodium hydrogen phosphate per litre; or by half-neutralising as below
9.18 Borax, 0.01 molar 3.81 g of clear, unweathered borax crystals per litre
10.01 Carbonate 2.10 g baking soda + 2.65 g washing soda dried at red heat per litre
12.45 Saturated lime water Shake slaked lime with water, let it settle, filter. Keep it sealed: air turns it to chalk. Reads 12.6 at 20 °C, 12.3 at 30 °C

Borax (9.18), cream of tartar (3.56) and lime water (12.45) are the most useful: three exact points made from things you already have.

The acetate standard by half-neutralisation. Measure two equal portions of the same vinegar, say 100 ml each. To one, add washing-soda solution a little at a time, swirling, until a few drops of cabbage indicator in a test sample just turn from purple to blue-green (all the acid neutralised). Boil it a minute to drive off the gas. Pour in the second, untouched 100 ml. Now half the acetic acid is neutralised: pH about 4.7, whatever the strength of the vinegar. Dilute to about 1 litre.

The phosphate standard by the same trick. Titrate a measured portion of phosphoric acid with soda standard until phenolphthalein turns faintly pink (or cabbage turns from blue to green): that volume, V, neutralises two of its three hydrogens. To a fresh, equal portion of the acid, add exactly ¾ V of the soda standard. That is half-way through the second hydrogen: pH about 6.9–7.0.

Store standards in clean, stoppered glass bottles, labelled with the pH and date. Make alkaline ones fresh every month and keep them out of air.

Method 2: pH paper and the colour chart

1. The reference ladderbottles of known pH, made from weighed pure substances pH 1.1hydrochloricacid 0.1 M pH 3.56cream oftartar pH 4.7acetate(vinegar) pH 6.86phosphate pH 9.18borax pH 10.0carbonate pH 12.45limewater 2. A drop on each stripread after 15 seconds in daylight 3. Paint the colour chartmatch each colour in watercolour beside its pH; one chart per batch of paper 1 2 3 4 5 6 7 8 9 10 11 12 13 red: strong acidgreen: neutralviolet: strong alkali
Fig. 2 Making pH papers and their colour chart. Strips of indicator paper are dipped in each solution of the reference ladder, and the colour of each is painted beside its pH on a card kept with the papers. The colours shown are those of a universal indicator.

pH paper is filter paper soaked in indicator and dried. Make two kinds:

  • Wide-range paper reads the whole scale to about ±1 unit: strong cabbage extract, or universal indicator.
  • Narrow-range papers each read a 2-unit band to about ±0.3 units: one indicator each — methyl orange (3–4.5), methyl red (4.5–6), bromothymol blue (6–7.6), turmeric (7.4–8.6), phenolphthalein (8–10).
  1. Paper. Use thick, pure filter paper, washed in distilled water and dried. Ordinary paper contains size and chalk that shift the colour.
  2. Soak. Dip whole sheets in the indicator solution: for synthetic dyes about 0.1 g in 100 ml of half-and-half spirit and water; for cabbage, extract boiled down to a tenth, with one-fifth of its volume of spirit. Hang them to dry in the dark, away from acid or ammonia fumes.
  3. Cut into strips 6 mm × 60 mm. Bind 50 in a little booklet or store them in a stoppered dark glass tube.
  4. Paint the colour chart. Put a drop of each reference solution, and of buffers made half-way between them, on a strip and look at it after 15 seconds in daylight. Mix watercolours (Pigments, Paints and Varnish) to match each colour exactly and paint a 1 cm square on a white card beside its pH number. Don't glue the wet strips themselves to the card — they fade within weeks. Make a chart for each batch of paper.
  5. To use, touch a drop of the sample to a strip with a clean glass rod, wait 15 seconds, and compare in daylight. Never dip the strip in a stock bottle. Coloured or cloudy samples hide the colour: dilute them, or use the meter.

A good pH paper turns the right colour within 5 seconds, matches the chart within half a step on the standards, and does not bleed colour into a drop of distilled water. A bad one is blotchy (uneven soaking), slow (paper too sized), or has drifted (old, stored in light or fumes). Check every booklet against borax and cream of tartar every month.

Method 3: Mixing buffer solutions

A buffer solution is made for a job, at the pH and strength the job needs.

  1. Choose the pair whose pKa is within one unit of the pH you want (table above).
  2. Decide the strength: 0.05–0.2 moles per litre for most work. Stronger holds better against added acid or alkali but tastes and stains more.
  3. Neutralise the right fraction of the weak acid, using the half-neutralisation table. Titrate a sample first to find how much alkali neutralises all of it, then add that fraction.
  4. Check the result with narrow-range paper or the meter against a reference, and nudge it with a few drops of acid or alkali.

Worked example: an acetate dye bath at pH 5.2. 10 ml of your vinegar needs 14 ml of soda standard to neutralise it fully (Acids, Bases and Testing). pH 5.2 is about 0.5 above acetic acid's 4.76, which needs 75 % neutralised. So for every 10 ml of vinegar add 10.5 ml of soda standard. Make up the whole bath in the same proportions.

Everyday buffers worth keeping:

Buffer pH Recipe per litre Use
Acetate 4.7 Half-neutralised vinegar (above), about 6 g acetic acid Dyeing wool and silk, photographic stop bath
Citrate about 5 21 g citric acid + 165 ml of 1-molar caustic soda (40 g per litre) Food work, cleaning, eye-safe rinses
Phosphate 7.0–7.4 Phosphate standard, at 5–10 times the strength; adjust with soda Biology, bacterial media (Culturing Microbes), eye drops with salt (Pharmacy: Tablets, Capsules, Ointments and Inhalers)
Borate 8.5–9.2 19 g borax, adjusted down with boric acid Eye washes, calibrating meters
Carbonate 10 Carbonate standard at 4 times strength Wool scouring, developers

A buffer for the body must also have the right saltiness, about the same as 9 g of salt per litre. Eye drops are usually a weak phosphate or borate buffer near pH 7–7.5 with salt to match; see Pharmacy: Tablets, Capsules, Ointments and Inhalers and Intravenous Fluids. Anything for eyes or veins must be sterile (Sterilising Instruments and Dressings).

Method 4: The pH meter

2471012 zeroslope Glass electrode filled with 0.1 M hydrochloric acid; silver-chloride wire Thin glass bulb 8–10 mm across, wall about 0.1 mm; never let it dry Reference electrode silver-chloride wire in saturated potassium chloride Porous junction clay plug: seeps a drop an hour Screened cable to the electrometer valve grid Meter in earthed metal box must draw almost no current; about 59 mV per pH unit sample, stirred, then read when steady
Fig. 3 A glass-electrode pH meter. A thin bulb of special glass develops a voltage that changes by about 59 millivolts per pH unit; it is read against a silver-chloride reference electrode by a meter that draws almost no current.

A pH meter measures a small voltage that changes with pH: about 59 millivolts per pH unit at 25 °C. It needs two electrodes dipped in the sample — one that responds to pH, and a reference electrode that does not — and a voltmeter.

The reference electrode

  1. Coat a silver wire (1 mm, 5 cm long) with silver chloride: make it the positive pole of a 1.5 V cell in dilute hydrochloric acid, with a carbon rod as the negative, for 20–30 minutes, until it is evenly purple-brown (Electrolysis, Silver Nitrate and Silver Salts).
  2. Mount it in a glass tube about 8 mm wide, filled with saturated potassium chloride (from potash and hydrochloric acid) with a few crystals undissolved.
  3. Close the bottom with a liquid junction: a plug of unglazed fired clay, a few glass fibres sealed into the tip (Glass Fibre and Glass Wool), or a ground-glass sleeve. The salt solution should seep out very slowly — a drop an hour or less.
  4. A good one gives the same voltage within 1 mV, day after day, against a second one in the same solution.

The antimony electrode (the simplest pH meter)

Cast a rod of pure antimony 5–6 mm thick and 6 cm long in a glass tube mould (Antimony and Bismuth), seal a copper wire to its top, and fit it in a tube so only the bottom 2 cm shows. Polish the tip with fine emery before each day's use. Its thin oxide skin gives a voltage against the reference electrode that changes by about 50–58 mV per pH unit from pH 2 to 11. Because its resistance is low, any good millivoltmeter or potentiometer reads it (Measuring Electricity). Calibrate with two or three standards every day; it is accurate to about ±0.2 pH. Oxidisers, dissolved copper and strong stirring upset it. It is ideal for soil, water, food and rough plant work.

The glass electrode (accurate to 0.05 pH)

  1. The glass. Melt special pH-sensitive glass from 72 parts clean sand, 38 parts dry soda ash and 11 parts chalk by weight, which gives about 72 % silica, 22 % soda and 6 % lime in the glass (Glass, Optical Glass and Achromatic Lenses).
  2. Blow the bulb. On the end of a 6–8 mm tube of ordinary glass, fuse a blob of the special glass and blow it into a bulb 8–10 mm across with walls about 0.1 mm thick — thin enough to flex under a gentle touch (Scientific Glassblowing and Glass-to-Metal Seals).
  3. Fill it with 0.1-molar hydrochloric acid (pH 1.1), or with pH-7 phosphate buffer containing potassium chloride.
  4. Insert a silver/silver-chloride wire, as for the reference, and seal the top of the tube with wax around the wire.
  5. Soak the bulb in water or a pH 4–7 buffer for at least a day before first use. Never let it dry out: store it standing in buffer.

The meter

The glass bulb has a huge electrical resistance: 10 to 1,000 megohms. An ordinary meter, or even the 10-megohm valve voltmeter of Electronic Test Equipment, would draw current through it and read nonsense. The meter must draw less than a millionth of a millionth of an ampere.

  • The electrometer valve. Use a triode (The Vacuum Tube) run gently: filament below its rated heat, only 6–12 V on the anode, and the grid wire brought out on its own through a clean, dry insulator of amber, paraffin wax or glass — never through the valve base. Wire the glass electrode to the grid, the reference to the cathode, and read the anode current on a sensitive meter. A second, matched valve in a balanced pair cancels drift (Amplifiers and Oscillators). Later, a field-effect transistor does the same job far more simply (Semiconductors and the Transistor).
  • Or a balance. Oppose the electrode voltage with an adjustable known voltage from a potentiometer, and use the valve only as a null detector: when it shows no change, read the potentiometer.
  • Shield it. The electrode lead must be screened cable, and the whole meter in an earthed metal box; a hand moving near an unscreened lead swings the reading.

Calibrating and using it

  1. Rinse both electrodes in distilled water and dip them in phosphate standard (6.86). Set the zero knob so the meter reads 6.86.
  2. Rinse, dip in cream of tartar (3.56) for acid samples or borax (9.18) for alkaline ones. Set the slope knob to read that value.
  3. Rinse, and measure your sample. Stir, then read when the needle is steady (30 seconds to a minute).
  4. Recalibrate daily, and whenever the temperature changes by more than 5 °C: the slope is 54 mV per unit at 0 °C, 59 at 25 °C and 62 at 37 °C.

A good pH meter reads the third standard within 0.05 when calibrated on the other two, settles within a minute, and drifts less than 0.02 in ten minutes. If it reads all standards close to 7 and responds slowly, the glass bulb is too thick or has dried out.

Using pH

Where Target
Canning in a boiling-water bath pH 4.6 or below — aim for 4.2. Above 4.6, pressure-can (Canning and Bottling)
Pickles, sauerkraut 4.0 or below (Vinegar and Pickling, Starter Cultures and Food Microbiology)
Jam setting with pectin 3.0–3.3 (Sugar)
Cheese curd at draining about 4.6–5.3, depending on the cheese (Dairy and Cheese)
Sourdough 3.8–4.5 (Grain, Flour and Bread)
Beer mash; wine 5.2–5.6; 3.2–3.6 (Beer, Wine and Cider)
Drinking water 6.5–8.5; chlorine works best below 8 (Water Treatment for a Town, Chlorine and Bleach)
Blood; eye drops 7.35–7.45; 6.5–7.8
Most crops; potatoes; blueberries 6–7; 5–6; 4.5–5.5 (Understanding Soil)
Acid dyes on wool; indigo vat 3–5; about 11 (Dyes and Mordants)
Nickel plating bath 3.5–4.5 (Electroplating)
Boiler water 10.5–11.5, to stop corrosion (Boilers and Pressure Vessels)

How to tell it worked

  • The ladder agrees with itself. Each paper colour falls in order, and a meter calibrated on two standards reads the others within 0.1.
  • Buffers resist. Add 1 ml of 0.1-molar hydrochloric acid to 50 ml of your buffer: the pH should move less than 0.1. The same acid in 50 ml of distilled water drops it from about 6 to about 3.

Note Troubleshooting. Distilled water reads 5.5–6, not 7 → dissolved carbon dioxide. Normal. Boil it, or ignore it: unbuffered water is the worst sample to measure. Paper colours hard to read → judge in daylight against a white card, after 15 seconds, not longer. Coloured samples: use the meter. Borax standard reads low → old borax that has lost water (white, chalky crystals). Use clear crystals. Meter drifts or wanders → damp insulation on the glass-electrode lead, or no shielding. Dry it, use wax and amber, earth the box. Meter slow and sluggish → glass bulb dried out or coated with fat or protein. Soak a day; clean in dilute hydrochloric acid. Antimony readings jump → tip not freshly polished, or stirring too fast. Polish and read in still liquid. Strongly alkaline samples read too low on glass → "sodium error" above about pH 10; use the lime-water standard close to the sample, or titrate instead.

Dangers

Warning The 30 % hydrochloric acid and the caustic soda used for standards and buffers burn skin and can blind. Wear eye protection, pour acid into water, never the reverse, and keep a bucket of clean water at hand. A splash in the eye: rinse it under gently running water for at least 15 minutes, holding the lids open, then get help. Follow the habits in Acids, Bases and Testing.

  • Synthetic indicators are dyes: some are poisonous (methyl orange) and phenolphthalein was once used as a laxative and is now suspected of causing cancer. Never use the indicator spoons or vessels for food, and don't put a pH paper in your mouth.
  • Spirit for indicator solutions is flammable; keep it from flames.
  • Thin glass bulbs break into slivers: handle the electrode by its stem.
  • If you use a calomel reference electrode instead of silver chloride, it contains mercury (Mercury).

Warning Don't trust one reading where lives depend on it. For canning and anything for eyes or veins, check pH by two methods — paper and meter, or meter and a fresh standard. A reading that is off by half a unit can mean botulism or a burnt eye.

What this unlocks

How it was first done

Litmus and plant colours had been used for centuries to tell acid from alkali (Acids, Bases and Testing). In 1909 the Danish chemist Søren Sørensen, working on proteins and beer at the Carlsberg Laboratory in Copenhagen, defined pH and made the first standard buffer solutions. In the same years Lawrence Henderson (1908) and Karl Hasselbalch (1916) worked out the buffer rule from their study of blood. Max Cremer discovered in 1906 that thin glass develops a voltage that depends on acidity, and Fritz Haber and Zygmunt Klemensiewicz made the first glass electrode in 1909. The pH meter became an everyday instrument after Arnold Beckman in California built a valve-amplified glass-electrode meter in 1934, first for testing lemon juice for the citrus growers.

Source: content/entries/chemistry/ph-and-buffers.md