Particle Accelerators (Overview)

Machines that speed charged particles through a vacuum to energies no chemical or electrical process gives naturally — to make penetrating X-rays for treating cancer, to sterilise medical supplies, to make radioactive tracers for medicine, to change the surface of materials and to look inside the atom. The voltage multiplier and the Van de Graaff generator, the cyclotron and the linear accelerator, what each is used for, and, before anything else, how to keep their radiation from killing the people who run them.

Difficulty
●●●●●
Time
A weekend for a demonstration belt generator; months for a 100–300 kV ion accelerator; years and a trained team for a cyclotron or a medical linear accelerator
Steps from zero
45 prerequisites →

You need first

High-Vacuum Pumps and GaugesX-RaysDetecting Radiation

This unlocks

Radiotherapy (Overview)

Raw materials

silkrubber tree
The full path from nothing — 45 steps before this one
  1. Fire
  2. Stone Tools
  3. Cordage and Rope
  4. Finding and Preparing Clay
  5. Finding and Identifying Ores
  6. Sulfur
  7. Basic Woodworking
  8. Hunting and Trapping
  9. The Kiln
  10. Pottery
  11. Charcoal
  12. Hides and Leather
  13. Lime
  14. Mercury
  15. Lye and Potash
  16. Fermentation
  17. The Wheel and Axle
  18. Glass
  19. Bellows
  20. Saltpeter
  21. The Lathe
  22. Copper Smelting
  23. Lead
  24. Iron (the Bloomery)
  25. Laboratory Glassware
  26. Sulfuric Acid
  27. Pumps
  28. Static Electricity and the Leyden Jar
  29. Lenses
  30. Gold and Silver
  31. Blacksmithing
  32. Nitric Acid
  33. The Vacuum Pump
  34. The Battery
  35. Silver Nitrate and Silver Salts
  36. The Light Bulb
  37. Copper Wire
  38. The Electromagnet
  39. The Vacuum Tube
  40. Mirrors
  41. The Induction Coil
  42. Detecting Radiation
  43. Vacuum Coating and Thin Films
  44. X-Rays
  45. High-Vacuum Pumps and Gauges
  46. Particle Accelerators (Overview)

Do them roughly in this order. See it on the tech tree →

Why it matters

An X-ray tube is a particle accelerator: a hundred thousand volts speeds electrons across a vacuum and they make X-rays when they hit the target. Go to millions of volts and new things become possible:

  • Radiotherapy. X-rays of several million volts reach a tumour deep in the body while sparing the skin. About half of all people with cancer are treated with radiation at some point, and most of that comes from linear accelerators (Radiotherapy (Overview), Chronic Diseases).
  • Medical tracers. Protons and deuterons from a cyclotron turn ordinary atoms into short-lived radioactive ones that doctors follow through the body (Ultrasound, CT and MRI).
  • Sterilising and toughening. Electron beams kill every germ in sealed packs of syringes, dressings and food without heat (Sterilising Instruments and Dressings), and cross-link plastics so cable insulation stands heat (Petrochemicals and Modern Plastics).
  • Industry. Megavolt X-rays see through 30 cm of steel to check welds and castings (Welding, Metal Casting). Ion beams of 10–200 kV drive impurity atoms into silicon to make transistors (Making Microchips).
  • Knowledge. Every fact in Nuclear Energy (Overview) about what nuclei are made of was found with accelerators.

This chapter is an overview. A demonstration belt generator is a weekend's work; a small ion accelerator is possible for a settlement with High-Vacuum Pumps and Gauges, Detecting Radiation and good electrical skills; a cyclotron or medical accelerator needs a trained team. Every one of them that accelerates particles in a vacuum is, the moment it works, a radiation hazard that can kill. Read the radiation sections first.

How it works

Energy in electron-volts

A particle with one electronic charge that falls through 1 volt gains 1 electron-volt (eV) of energy. Through 100,000 volts it gains 100 keV (kilo-electron-volts); through a million, 1 MeV. A particle can get its energy two ways:

  1. One big voltage. Make a very high voltage and let the particle fall through it once: the voltage multiplier and the Van de Graaff. Simple and steady, but in air the sparks stop you at about 1 MV, and even in a tank of pressurised gas at about 25 MV.
  2. Many small pushes. Give the particle a few thousand volts many times over, in step with an alternating voltage: the cyclotron (round and round in a magnet) and the linear accelerator (along a straight pipe). This has no upper limit except size and money.
Energy What it does
20–150 keV electrons X-ray tubes, The Electron Microscope, Cathode Rays and Television tubes
10–400 keV ions Implanting atoms into chips; surface hardening
0.1–1 MeV protons Split light nuclei such as lithium
1–10 MeV electrons Sterilisation, radiotherapy, steel radiography
10–20 MeV protons and deuterons Making medical tracers
Above 100 MeV Research; proton therapy

Everything needs a vacuum

The particles must travel metres without hitting a gas molecule: 10⁻⁵ mm of mercury at least, 10⁻⁶ or better for long paths (High-Vacuum Pumps and Gauges, Ion Pumps and Leak Detectors).

Radiation comes first

Danger An accelerator is a radiation source whenever it is switched on — not only when you think there is a beam. Every accelerator above about 10 kV makes X-rays wherever electrons strike metal, including electrons going the wrong way. Proton and deuteron beams make neutrons and gamma rays when they strike a target. The beam itself, at full energy, burns through flesh in seconds. Radiation gives no sensation at all, and the damage appears days or weeks later (X-Rays, Nuclear Energy (Overview)).

How strong it is:

  • The X-ray beam of a hospital linear accelerator gives 2–6 grays a minute at a metre. A whole-body dose of 4–5 grays kills about half of those who receive it (Nuclear Energy (Overview)). The raw electron beam before it hits the target is thousands of times more intense.
  • In an ion accelerator, stray electrons knocked loose inside the tube are speeded the other way, up to the terminal, and make X-rays there — a common fault that turns a 300 kV machine into a large X-ray tube that nobody aimed.
  • Deuterons on deuterium make neutrons at only 100 kV. Deuterium builds up in any target struck by deuterons, so after a while every such target is a neutron source. Neutrons pass through lead and make other materials radioactive.
  • Activation. Targets, beam stops, slits and cyclotron parts become radioactive and stay so for hours to years after the machine is switched off.

The rules — time, distance, shielding, and keeping radioactive material outside the body — are those of Nuclear Energy (Overview) and X-Rays; for accelerators they take the form of the shielded vault, below. No one should run any accelerator who does not own and use a working Geiger counter and wear a dose badge (Detecting Radiation).

What you need

Item Use Source
High-vacuum bench, 10⁻⁵–10⁻⁶ mm Every accelerator High-Vacuum Pumps and Gauges
Transformers, rectifiers, capacitors for 10–50 kV Voltage multipliers The Transformer, Rectifiers: Turning AC into DC, Resistors, Capacitors and Coils
Spun aluminium or copper hemispheres Smooth high-voltage terminals Metal Spinning and Raising
Glass or porcelain rings; aluminium or steel electrodes Accelerating tubes Scientific Glassblowing and Glass-to-Metal Seals, Stoneware and Porcelain
Large soft-iron forgings and copper coils Cyclotron magnet The Electromagnet, Steel
Radio-frequency oscillators; magnetrons Cyclotron and linac Amplifiers and Oscillators, Radar and Microwaves
Geiger counter, ion chamber, film badges Measuring radiation Detecting Radiation
Concrete, earth, lead, water, paraffin wax Shielding Mortar and Concrete, Lead

The voltage multiplier

Voltage multiplier Van de Graaff generator +100 kV out 2 × 5 stages × 10 kV Rectifiers 20 kV each DC column steady, climbs 20 kV per stage Pumping column swings with the AC 0.01 µF, 20 kV each Transformer 10 kV peak earth ++++ ++++++ Hollow sphere 25–40 cm, polished; charge sits outside Upper comb wired to the sphere Rubber belt 5–8 cm wide, carries charge up Lower comb earthed Insulating column glass, waxed Rollers felt below, metal above Motor 200–300 kV, 1–10 µA; sparks 10–15 cm
Fig. 1 Two ways to make a big steady voltage. Left: a voltage multiplier — a ladder of capacitors and rectifiers that pumps charge up stage by stage from a transformer, each stage adding twice the transformer's peak voltage. Right: a Van de Graaff generator — a moving belt carries charge sprayed onto it at the bottom up into a hollow metal sphere, where a comb takes it off and it spreads over the outside.

A ladder of capacitors and rectifiers (the Cockcroft–Walton or Greinacher circuit) that turns an alternating voltage of peak V into a steady direct voltage of up to 2 × V × the number of stages.

How it works. Two columns of capacitors stand side by side. Rectifiers zig-zag between them. On each half-cycle of the transformer, charge is passed one step up the ladder; after many cycles each capacitor in the right-hand column holds 2V, and the top of the column sits at 2nV above earth.

Sizes for a small one (100 kV):

Part Size
Transformer 7,000 V r.m.s. (10 kV peak), 50–100 mA (The Transformer)
Stages 5, giving 100 kV with no load
Capacitors 10 in all, five in each column, each 0.01 µF rated for 20 kV (the first for 10 kV)
Rectifiers 10, each rated for 20 kV reverse voltage
Column height about 1 m, on insulating rods of glass, varnished hardwood or porcelain

The catch: it sags under load. The voltage drop grows as the cube of the number of stages. Five stages at 50 Hz with 0.01 µF capacitors lose about 2 kV and ripple by 300 V at a 10 µA beam, but ten times as much at 100 µA. Cures: fewer stages and a bigger transformer, bigger capacitors, or feed it from a 1–10 kHz oscillator instead of the mains, which cuts sag and ripple twenty- to two-hundredfold.

Making it.

  1. Rectifiers. Selenium or silicon stacks are simplest (Rectifiers: Turning AC into DC, Semiconductors and the Transistor). Vacuum diodes work, but each filament then floats at a different high voltage and needs its own heater supply insulated for it.
  2. Capacitors. Oil-paper rolls in glass or porcelain tubes, or stacks of glass plates and foil — Leyden jars in modern form (Resistors, Capacitors and Coils, Static Electricity and the Leyden Jar).
  3. Smoothness against corona. Every point, wire end and screw head at high voltage leaks charge into the air with a hiss, a violet glow and a smell of ozone. Join the stages with smooth metal tubes, put a polished ring (a corona ring) round each stage, and top the column with a smooth dome.
  4. Clearance. Keep everything at high voltage at least 3 cm from earthed objects for every 10 kV — 30 cm at 100 kV — and much more near points.
  5. Bleeder. A long chain of resistors from top to earth, about 1,000 MΩ for 100 kV, drains the column when switched off, and a microammeter at its bottom end reads the voltage. Still earth the top with an earthing rod before touching it.

The same ladder powers X-ray tubes, the The Electron Microscope, picture tubes and photocopiers (Copying Documents and Xerography).

The Van de Graaff generator

A belt carries electric charge up into a hollow metal sphere. Charge put inside a hollow conductor goes straight to its outside surface, so the sphere can be charged higher and higher until sparks or leakage stop it.

A demonstration machine (200–300 kV)

  1. Column. A tube of glass, or of paper wound on a mandrel with shellac and baked, 8–10 cm across and 50–70 cm tall, on a wooden base. It must be clean and dry; wax it.
  2. Belt. An endless band 5–8 cm wide of thin natural rubber sheet (Rubber), or rubberised silk or cotton, joined with an overlapped and glued seam.
  3. Rollers. Two rollers 3–5 cm across. The lower one, driven by a motor at 1,500–3,000 turns a minute (The Electric Motor), is covered with a material that charges the belt by rubbing — wool felt or glass; the upper one, free-running, with a different material — bare metal or another plastic. The pair you choose sets which sign of charge goes up (Static Electricity and the Leyden Jar).
  4. Combs. A row of sharp wire points (or a strip of fine wire brush) a few millimetres from the belt at each roller. The lower comb is earthed; the upper comb is wired to the inside of the sphere.
  5. Sphere. Two spun aluminium or copper hemispheres 25–40 cm across, joined, polished and free of dents, sitting on the column (Metal Spinning and Raising). A pair of large smooth bowls will do.

The highest voltage a sphere can hold in air is about 30 kV for each centimetre of its radius: a 30 cm sphere could reach 450 kV in theory, 200–300 kV in practice, throwing sparks 10–15 cm long to an earthed ball. The belt carries 1–10 µA.

Larger machines

Real accelerators spray charge onto the belt from a 10–30 kV supply instead of by friction, and stand in a steel tank of dry nitrogen or carbon dioxide at 10–20 atmospheres, which resists sparking many times better than air: 2–5 MV in a tank a few metres long. Their great advantage is a very steady energy, which made them the precise tools of nuclear physics.

The accelerating tube

The tube that hangs below a multiplier or Van de Graaff terminal and carries the beam down to earth.

  1. Rings. A stack of short glass or porcelain rings, 2–3 cm long and 10–15 cm across, alternating with thin metal electrode discs that have a central hole of 2–3 cm, sealed together with wax, glue or (better) fused glass (Scientific Glassblowing and Glass-to-Metal Seals). No more than 10–20 kV per ring: a 300 kV tube is about 50 cm long.
  2. Voltage division. A chain of equal resistors outside joins each electrode to the next, so the voltage falls evenly down the tube.
  3. Ion source in the terminal. For protons: a small glass bottle with a trickle of hydrogen let in through a needle valve or a heated palladium tube, lit by a radio-frequency discharge (it glows pink-red) of a few tens of watts, and a probe at a few kilovolts that pushes the ions out through a small hole. For electrons: a hot filament (The Vacuum Tube).
  4. Target and pump at the earthed bottom end, the pump as large and close as possible.

The classic first experiment is that of 1932: protons of 150–400 keV on a target of lithium (or lithium fluoride). Each lithium-7 nucleus that captures a proton splits into two helium nuclei that fly apart with about 8.7 MeV each. They show as bright flashes on a zinc sulfide screen beside the target (Photomultipliers and Scintillation Counters), counted in the dark with a magnifier, or as tracks in a cloud chamber. Mass turned into energy, as Einstein's equation says, measured on a laboratory bench.

The cyclotron (in outline)

From above In section Dee hollow copper Ion source at the centre Target beam peeled off by the deflector RF oscillator 15.2 MHz per tesla for protons Iron magnet, 1–2 tonnes for a small one N pole S pole Coils several kW Vacuum chamber, dees inside field (dashed) straight through it
Fig. 2 A cyclotron seen from above and in section. Two hollow D-shaped copper electrodes, the dees, sit in a flat vacuum box between the poles of a large electromagnet. A radio-frequency voltage across the gap between the dees gives the ions a push each time they cross it, and the magnet bends them into a spiral that grows wider as they speed up, until a deflector plate leads them out to the target.

In a steady magnetic field a charged particle goes round in a circle, and — the key fact — the time for one turn does not depend on its speed: faster particles go in wider circles at the same rate. So an alternating voltage of the right frequency across a gap can push the particle every time it crosses.

  • Dees. Two hollow, flat D-shaped boxes of copper sheet, the gap between their straight edges at the centre of a flat vacuum chamber, which sits between the poles of a big electromagnet.
  • Frequency. For protons, 15.2 MHz for each tesla of field; deuterons, 7.6 MHz. A powerful valve oscillator puts 5–50 kV across the dees (Amplifiers and Oscillators).
  • Energy. Protons leaving at radius r metres in field B teslas have about 48 × (B × r)² MeV.
  • Ion source at the centre, between the dees; a deflector plate at high voltage peels the beam off at the edge onto the target.
Example Pole diameter Field Energy
Lawrence's 11-inch, 1932 28 cm 1.3 T protons 1.2 MeV
A first settlement machine 25 cm 1.2 T protons about 0.8 MeV
Lawrence's 60-inch, 1939 1.5 m about 1.2 T deuterons 16 MeV
Hospital isotope cyclotron 1–1.5 m 1.5–2 T protons 10–18 MeV

The magnet is the cost: one or two tonnes of soft iron and several kilowatts of coil for a small one, hundreds of tonnes for the big ones (The Electromagnet). The field must fall off very slightly towards the edge to keep the beam focused, and be the same all round to a fraction of a percent. Map it point by point with a Hall probe (Hall Sensors and Magnetometers) and correct it with thin iron shims.

Its limit. As protons pass about 20 MeV they gain mass by relativity, fall out of step and stop gaining energy. Later machines change the frequency (the synchrocyclotron) or shape the field (the isochronous cyclotron). Electrons fall out of step almost at once, so they are accelerated instead in the betatron, a ring-shaped tube in a magnet whose rising flux drives them like the secondary of a transformer, or in linear accelerators.

The linear accelerator (in outline)

Particles travel along a straight vacuum pipe, pushed repeatedly by radio-frequency fields.

  • Drift tubes (for ions). A row of metal tubes along the axis, connected alternately to the two sides of an oscillator. Inside a tube the particle feels no force; at each gap it is pushed. As it speeds up, each tube must be longer than the last, so the particle always reaches the next gap as the voltage reverses.
  • Travelling-wave guide (for electrons). By about 1 MeV electrons travel at nearly the speed of light; after that they barely go faster, they only gain energy. A copper pipe divided by discs with central holes carries a microwave whose crests travel at the speed of light; electrons ride on a crest like surfers.

The medical linear accelerator

  1. Microwaves. A magnetron or klystron of 2–5 MW peak, in pulses of a few millionths of a second a few hundred times a second, at about 3,000 MHz (Radar and Microwaves).
  2. Electron gun at 15–50 kV injects electrons into the guide.
  3. Accelerating guide. 30 cm to 1 m of disc-loaded copper pipe, machined to a few thousandths of a millimetre, water-cooled and pumped by an ion pump: 4–6 MeV. Longer guides and a bending magnet give 10–20 MeV.
  4. Target. The electrons strike a water-cooled tungsten plate and make X-rays (Tungsten and Filament Wire). A cone of metal (the flattening filter) evens the beam out; for electron treatment the target is withdrawn and a thin foil spreads the beam instead.
  5. Dose monitors. Two independent ionisation chambers in the beam measure every unit delivered, each able to stop the beam on its own.
  6. Collimator. Thick tungsten jaws shape the beam to the tumour.
  7. Gantry. The whole head turns round the patient so that the beam always passes through one point, 100 cm from the target, where the tumour is placed, and enters from many sides.

Why megavolts. A beam of 200–300 kV X-rays gives its greatest dose at the skin and only about a third of it 10 cm deep; skin and bone are burned before a deep tumour is treated. A 6 MV beam builds up to its maximum 1.5 cm under the skin and still gives about two-thirds of it at 10 cm. Treatment is divided into daily doses of about 2 grays, five days a week for five to seven weeks, so that healthy tissue repairs between sessions. Planning, calibration and treatment are skilled medical work (Radiotherapy (Overview), Running a Hospital).

The accelerator vault

Primary wall the beam can point here: 1.5 m of concrete at 6 MV Secondary wall, about 1 m Search button pressed last, at the far end Emergency stops (red) inside and in the maze Accelerator head turns round the patient Treatment couch Radiation monitor with a display at the door Door interlock opening it stops the beam Control desk Warning lamp lit before and during beam Maze Plan view. Grey: concrete. Blue dots: scatter must turn corners.
Fig. 3 Plan of a shielded room for a medical linear accelerator. Thick concrete walls, thickest where the beam can point, surround the machine. The only entrance is a bent passage, the maze, so radiation must scatter several times before reaching the door. The control desk is outside. Warning lights, a door interlock, emergency-off buttons inside and a last-person-out search key protect anyone who might be inside.

Every accelerator above a few hundred kilovolts lives in a vault. Smaller ones still need shielding round the target and an interlocked fence.

Walls. Radiation is cut to a tenth by each tenth-value layer of shielding. For 6 MV X-rays that is about 37 cm of ordinary concrete or 5.7 cm of lead. The primary walls, where the beam can point, need about 1.5 m of concrete for a 6 MV machine; the rest, which see only scattered radiation and leakage, about 1 m. Packed earth is about two-thirds as good as concrete for the same thickness, so a vault can be dug into a hillside (Tunnels and Rock Drilling). Lead only where space is short.

Neutrons. Above about 10 MV, and with any proton or deuteron beam, add materials rich in hydrogen — water, paraffin wax, concrete — round the target and at the door. Lead does little against neutrons.

The maze. The entrance is a passage with one or two turns, so radiation must bounce several times, losing most of its strength at each bounce, before it reaches the door.

Interlocks and procedures:

  1. The door switch. The beam cannot start unless the door is closed, and stops instantly if it opens. Wire it in series through the beam-on circuit so that a broken wire stops the beam (Wiring and Electrical Safety). Never bridge an interlock "just for a minute".
  2. Search and key. Before every start, the operator walks the vault, presses a search button at the far end within a set time, and leaves; only then does the key at the desk work. One key, on the operator's person.
  3. Warnings. A lamp at the door and inside the vault lights before and during beam; a horn sounds before it starts.
  4. Emergency stops. Large red buttons inside the vault and maze, where anyone trapped can reach them.
  5. Fixed monitors. A radiation monitor inside the vault, with a display at the door, so nobody walks into a beam or a hot room.
  6. Badges. Everyone wears a film badge or a pocket ion chamber, read every month (Detecting Radiation). Limits: 20 mSv a year for workers, 1 mSv a year for the public outside.
  7. After switch-off. Survey with a Geiger counter before going near targets, slits or beam stops; handle activated parts with tongs and store them behind shielding.
  8. Log every run, every fault, every dose.

How to tell it worked

  • Multiplier: the bleeder meter reads within a few percent of 2nV at no load; no hiss or glow in a darkened room.
  • Van de Graaff: sparks of 10–15 cm to an earthed ball; light hair stands on end on an insulated stool (healthy volunteers only).
  • Ion accelerator: a glowing spot on a quartz plate at the target; alpha flashes from lithium rising steeply above 100 kV.
  • Shielding: a survey with a Geiger counter all round the outside of the vault at full beam shows no more than natural background in public places.

Note Troubleshooting. Multiplier voltage sags badly under load → too many stages for the frequency; raise frequency or capacitance. Hissing, violet glow, ozone smell → corona from points and thin wires; smooth and enlarge everything at high voltage. Van de Graaff gives little → damp air or a dirty column and belt; dry the room, wipe and warm the column, change roller materials. Accelerating tube sparks inside, vacuum bursts → too many kilovolts per ring, or gas and dust; condition it by raising the voltage slowly over days. X-ray monitor reads high with no ion beam → electrons running back up the tube; add a small magnet or suppressor electrodes. Cyclotron beam lost halfway out → magnetic field not falling off correctly, or frequency not matched; remap and shim.

Dangers

Danger Radiation. Treat every accelerator as live whenever it has power, including high voltage on a Van de Graaff with an accelerating tube and microwaves on a linac with no injected beam. Shield first, interlock second, survey always. In Hanoi in 1992 a physicist reached into the irradiation area of a small research electron accelerator to adjust a sample while the beam was on; his hands received doses so high that parts of them had to be amputated. Between 1985 and 1987 the Therac-25 medical accelerator, whose makers had replaced hardware interlocks with software, gave six patients massive overdoses through program errors, and several died. Use hardware interlocks that fail safe, and believe your radiation monitor over your control panel.

Danger High voltage. Multipliers and capacitors store charge long after switch-off and kill. Earth every terminal with an earthing rod on an insulating pole before touching. A demonstration Van de Graaff gives a painful but normally harmless shock of under a joule — but never connect it to Leyden jars or capacitors, and keep it away from anyone with a heart pacemaker and from electronics.

  • Microwaves from linac guides burn deep tissue and eyes (Radar and Microwaves).
  • Ozone and nitrogen oxides form wherever a beam or corona passes through air; ventilate the vault.
  • Heavy magnets pull steel tools out of hands with crushing force; cyclotron coils carry hundreds of amperes.
  • Activated parts and radioactive targets — never take them home, never melt them as scrap, label and store them (Nuclear Energy (Overview)).
  • Vacuum, cryogenic and oil hazards as in High-Vacuum Pumps and Gauges.

What this unlocks

The uses listed at the top of this chapter, and the steady high voltages of the The Electron Microscope. The ion pumps, magnets and microwave sources that accelerators demand (Ion Pumps and Leak Detectors, Radar and Microwaves) feed back into every other high-vacuum and radio art.

How it was first done

Ernest Rutherford, who had split nitrogen with natural alpha particles in 1919, asked in 1927 for a "copious supply" of particles more energetic than radium gives. Rolf Wideröe built the first linear accelerator in Aachen in 1928, giving potassium ions 50 keV. Robert Van de Graaff built his first belt generator at Princeton in 1929, with a silk ribbon, and showed 1.5 MV in 1931. In April 1932 John Cockcroft and Ernest Walton at the Cavendish Laboratory, Cambridge, using Heinrich Greinacher's multiplier circuit of 1919, split lithium nuclei with protons of a few hundred keV. Ernest Lawrence and Stanley Livingston at Berkeley ran the first working cyclotrons in 1931–32; Lawrence's brother John used their neutrons and tracers in medicine from 1936. Donald Kerst built the betatron in 1940. William Hansen's group at Stanford accelerated electrons in a disc-loaded guide in 1947, the first medical linear accelerator treated patients at Hammersmith Hospital in London in 1953, and from the 1960s compact rotating linacs became the standard radiotherapy machine.